RAD Data comm operation manual Chapter Operation, Turning On RIC-155, Controls and Indicators

Page 27

Chapter 3

Operation

This chapter provides the following information for the RIC-155 converter:

RIC-155 indicators

Turning-on and turning-off the RIC-155

Default settings.

Installation procedures given in Chapter 2 must be completed and checked before attempting to operate RIC-155.

3.1Turning On RIC-155

To turn on RIC-155:

Connect the power cord to the mains.

The PWR indicator on the front panel lights up and remains on as long as RIC-155 receives power.

RIC-155 requires no operator attention once installed, with the exception of occasional monitoring of front panel indicators. Intervention is only required when RIC-155 must be configured to its operational requirements.

3.2Controls and Indicators

The front panel includes a series of LED indicators that show the current operating status of the unit. Figure 3-1illustrates front panel of the RIC-155 unit. Table 3-1lists and describes the indicator functions.

RIC-155

 

 

10/100 BaseT

 

 

 

SPEED

 

PWR

ALM

LINK/ACT

SIG

 

MNG

DATA

155 Mbps

Figure 3-1. RIC-155 Front Panel

Controls and Indicators

3-1

Image 27
Contents RIC-155 Page RIC-155 Limited Warranty Please observe the following precautions General Safety InstructionsGeneral Safety Practices Connection of AC MainsConnection of DC Mains Connection of Data and Telecommunications Cables Ports Safety StatusElectromagnetic Compatibility EMC Conventions Canadian Emission RequirementsSupplementary Information SafetyManufacturers Name Manufacturers Address Product NameInstalling RIC-155 Configuring RIC-155Quick Start Guide To configure RIC-155 Configuring RIC-155Contents Appendix A. Connector Wiring Appendix B. Traffic Separation Troubleshooting and DiagnosticsApplication Chapter IntroductionOverview VersionsFiber Optic Interface Options Features10/100BaseT Interface STM-1/OC-3c InterfaceStatus Reporting Alarm RelayManagement Internal BridgeRIC-155 3D View Physical DescriptionFunctional Description RIC-155 Block DiagramTechnical Specifications Temperature 50C / 32-122F Humidity Up to 90%, non-condensing Alarm Types Major and minor Connector DB-9, femaleIntroduction Chapter Installation and Setup IntroductionSite Requirements and Prerequisites Connecting the Interface Cables Package ContentsConnecting the Power Cable Connecting AC PowerConnecting DC Power Connecting the Power Cable To turn on RIC-155 Controls and IndicatorsChapter Operation Turning On RIC-155Name Function Location RIC-155 Normal Indicator StatusIndicator Status RIC-155 LEDsRIC-155 Default Settings Default SettingsUplink Configuration AlternativesParameter Default Value Managing RIC-155 via Terminal PortTo prepare RIC-155 for network management Managing RIC-155 via Ethernet PortsPreparing the Terminal Starting Terminal Session for a First TimeTo start a ConfiguRAD session Menu Map Loging onTo enter the user name and password Navigating the Management MenusTo choose an option terminal session To choose an option ConfiguRAD sessionChoosing Options Correcting EntriesTurning Off RIC-155 Navigating TablesLogging Out Operation Turning Off RIC-155 To access the Management menu Chapter ConfigurationConfiguring RIC-155 for Management To access the Configuration menuTo enter device information Entering Device InformationTo define the IP parameters Configuring the Host ParametersTo configure the network managers Configuring the Network ManagersTo define the management access method Controlling the Management AccessTo enable or disable management ports Configuring the RIC-155 for OperationConfiguring Control Port Parameters Configuring the Clock SourceEnabling and Disabling Pop-up Alarms Configuring the Security TimeoutChanging the Control Port Data Rate Configuring the Physical Ports Configuring the Ethernet InterfaceConfiguring the STM-1/OC-3c Interface 10E-3,10E-4,10E-5 10E-5,10E-6,10E-7,10E-8,10E-9J1 Path Trace Uplink Port Loss of Signal Uplink Port Signal LossLine Excessive Error Defect Line Signal Degraded ErrorMbps, 8 Mbps, No Limit Configuring the Internal BridgeConfiguring Fast Ethernet Bridge To configure the Fast Ethernet bridgeTo configure the Ethernet management and data bridge ports Configuring the Bridge PortsConfiguring Ethernet Management and Data Bridge Ports To access the Bridge Port menuTo configure the POS port Configuring the POS Bridge PortDisplaying the RIC-155 Status Displaying the System StatusTo display the system information Displaying the Port Status Displaying the Ethernet Port StatusTo display the Ethernet port status Parameters Values Displaying the STM-1/OC-3c Port StatusDATA/MNG Port Status Parameters To display the STM-1/OC-3c port statusSTM-1/OC-3c Port Status Parameters Changing the PasswordTo change the current password Additional TasksDisplaying the RIC-155 Inventory 21. User Access MenuInstalling Software Releases Installing a New Software Release via TftpTo install a new software release via Tftp To install a new software release via Xmodem Installing a New Software Release via XmodemDisplaying the Software Version Transferring Configuration FilesTo upload a configuration file To download a configuration fileSwitching Software Versions Resetting RIC-155To switch software versions To reset RIC-155 Resetting RIC-155 to Factory DefaultsResetting RIC-155 To reset RIC-155 to the defaultsTo display the Ethernet statistics Chapter Troubleshooting DiagnosticsMonitoring Performance Displaying the Ethernet StatisticsTo display the current SDH/SONET statistics Displaying SDH/SONET StatisticsDisplay Description Range Uplink Statistics Screen,Uasl RCV Abort 1explains all SDH/SONET statistics parameters To display SDH/SONET statistics for all intervalsFront Panel LEDs Detecting ErrorsHandling Alarms Power-Up Self-TestTo display the event log file Displaying System AlarmsTo display the system alarms Working with the Log FileConfiguring Alarm Severity To configure the alarm severityTo clear the event log Terminal Message Description Severity Masking Port AlarmsTo mask RIC-155 alarms RIC-155 Alarms and WarningsNumber Terminal Message Description RIC-155 EventsTroubleshooting and Diagnostics Handling Alarms Table A-1. ETH and MNG-ETH Connector Pinout Appendix a Connector WiringEthernet Connectors Alarm Relay ConnectorPin Alarm Relay Function Control ConnectorTable A-2. Alarm Connector Pinout Table A-3. Control Connector PinoutMNG only Appendix B Traffic SeparationPort-Based Traffic Separation NonePort-Based/VLAN-Based Traffic Separation AllLocal Mng Only Uplink and Host Ports Default TaggingTable B-1. Default Tagging Modes Tagging Modes of the Bridge PortsNone Forwarding Mode Port FilterManagement Access Mode None MNG Only All Local MNG Only Internal Operation Modes of the Bridge PortsAll MNG OnlyConfiguring for a Typical Application Managing RIC-155 via MNG PortLocal MNG Only Figure B-9. Managing RIC-155 via MNG Port Managing RIC-155 via Data PortFigure B-10. Managing RIC-155 via Data Port Index STM-1/OC-3c interface, 1-2,1-6 RADview-Lite,3-5Excellent Good Fair Poor Very Poor Customer Response FormPage Error Report Page Page International Headquarters