RAD Data comm RIC-155 operation manual Uplink Port Signal Loss, Line Excessive Error Defect

Page 47

RIC-155Installation and Operation ManualChapter 4 Configuration

Note

The following alarms trigger an uplink failure:

Uplink Port Signal Loss

 

 

Line Excessive Error Defect

 

Line Signal Degraded Error

 

Uplink Port Loss of Signal

 

Uplink Port Loss of Frame

 

Path Rx Facility Pointer Loss

 

Path Excessive Error Defect

 

Path Signal Degraded Error

 

Path Trace J1 string mismatch.

With Physical Failure Forwarding enabled, three additional alarms trigger an uplink failure:

Line Alarm Indication Signal (AIS-L)

Remote Line Defect Indication (RDI-L)

Unequipped.

It is possible to mask errors in the Alarm Setup menu, so that the uplink will not be interrupted. (See Chapter 5)

 

RIC-155

 

 

1.

Uplink Configuration

 

(SDH)

Uplink Mode:

 

2.

BER Threshold:

>

(Enabled)

3.

EED Threshold (10E-):

(10E-3)

4.

SD Threshold (10E-):

>

(10E-6)

5.

J1 Path Trace Configuration:

>

(Enabled)

6.

Send AIS-L (K2)...

 

7.

Send Unequipped (C2)

 

(Enabled)

8.

Physical failure forwarding

 

(Enabled)

8.

Physical failure forwarding on RDI-L/AIS-L/Unequipped

 

(Disabled)

Please select item <1 to 8>

ESC-prev.menu; !-main menu; &-exit

Figure 4-13. Uplink Configuration Menu

Note Item 9 of Figure 4-13,appears only when item 8, Physical failure forwarding, is enabled.

If item 9 is enabled, RIC-155 considers the RDI-L/AIS-L/Unequipped status in addition to all the other alarms in physical failure forwarding.

Configuring the Physical Ports

4-11

Image 47
Contents RIC-155 Page RIC-155 Limited Warranty Please observe the following precautions General Safety InstructionsConnection of DC Mains General Safety PracticesConnection of AC Mains Connection of Data and Telecommunications Cables Ports Safety StatusElectromagnetic Compatibility EMC Conventions Canadian Emission RequirementsSupplementary Information SafetyManufacturers Name Manufacturers Address Product NameQuick Start Guide Installing RIC-155Configuring RIC-155 To configure RIC-155 Configuring RIC-155Contents Appendix A. Connector Wiring Appendix B. Traffic Separation Troubleshooting and DiagnosticsApplication Chapter IntroductionOverview VersionsFiber Optic Interface Options Features10/100BaseT Interface STM-1/OC-3c InterfaceStatus Reporting Alarm RelayManagement Internal BridgeRIC-155 3D View Physical DescriptionFunctional Description RIC-155 Block DiagramTechnical Specifications Temperature 50C / 32-122F Humidity Up to 90%, non-condensing Alarm Types Major and minor Connector DB-9, femaleIntroduction Site Requirements and Prerequisites Chapter Installation and SetupIntroduction Connecting the Interface Cables Package ContentsConnecting DC Power Connecting the Power CableConnecting AC Power Connecting the Power Cable To turn on RIC-155 Controls and IndicatorsChapter Operation Turning On RIC-155Name Function Location RIC-155 Normal Indicator StatusIndicator Status RIC-155 LEDsRIC-155 Default Settings Default SettingsUplink Configuration AlternativesParameter Default Value Managing RIC-155 via Terminal PortTo prepare RIC-155 for network management Managing RIC-155 via Ethernet PortsPreparing the Terminal Starting Terminal Session for a First TimeTo start a ConfiguRAD session Menu Map Loging onTo enter the user name and password Navigating the Management MenusTo choose an option terminal session To choose an option ConfiguRAD sessionChoosing Options Correcting EntriesLogging Out Turning Off RIC-155Navigating Tables Operation Turning Off RIC-155 To access the Management menu Chapter ConfigurationConfiguring RIC-155 for Management To access the Configuration menuTo enter device information Entering Device InformationTo define the IP parameters Configuring the Host ParametersTo configure the network managers Configuring the Network ManagersTo define the management access method Controlling the Management AccessTo enable or disable management ports Configuring the RIC-155 for OperationConfiguring Control Port Parameters Configuring the Clock SourceChanging the Control Port Data Rate Enabling and Disabling Pop-up AlarmsConfiguring the Security Timeout Configuring the STM-1/OC-3c Interface Configuring the Physical PortsConfiguring the Ethernet Interface J1 Path Trace 10E-3,10E-4,10E-510E-5,10E-6,10E-7,10E-8,10E-9 Uplink Port Loss of Signal Uplink Port Signal LossLine Excessive Error Defect Line Signal Degraded ErrorMbps, 8 Mbps, No Limit Configuring the Internal BridgeConfiguring Fast Ethernet Bridge To configure the Fast Ethernet bridgeTo configure the Ethernet management and data bridge ports Configuring the Bridge PortsConfiguring Ethernet Management and Data Bridge Ports To access the Bridge Port menuTo configure the POS port Configuring the POS Bridge PortTo display the system information Displaying the RIC-155 StatusDisplaying the System Status To display the Ethernet port status Displaying the Port StatusDisplaying the Ethernet Port Status Parameters Values Displaying the STM-1/OC-3c Port StatusDATA/MNG Port Status Parameters To display the STM-1/OC-3c port statusSTM-1/OC-3c Port Status Parameters Changing the PasswordTo change the current password Additional TasksDisplaying the RIC-155 Inventory 21. User Access MenuTo install a new software release via Tftp Installing Software ReleasesInstalling a New Software Release via Tftp To install a new software release via Xmodem Installing a New Software Release via XmodemDisplaying the Software Version Transferring Configuration FilesTo upload a configuration file To download a configuration fileTo switch software versions Switching Software VersionsResetting RIC-155 To reset RIC-155 Resetting RIC-155 to Factory DefaultsResetting RIC-155 To reset RIC-155 to the defaultsTo display the Ethernet statistics Chapter Troubleshooting DiagnosticsMonitoring Performance Displaying the Ethernet StatisticsTo display the current SDH/SONET statistics Displaying SDH/SONET StatisticsDisplay Description Range Uplink Statistics Screen,Uasl RCV Abort 1explains all SDH/SONET statistics parameters To display SDH/SONET statistics for all intervalsFront Panel LEDs Detecting ErrorsHandling Alarms Power-Up Self-TestTo display the event log file Displaying System AlarmsTo display the system alarms Working with the Log FileTo clear the event log Configuring Alarm SeverityTo configure the alarm severity Terminal Message Description Severity Masking Port AlarmsTo mask RIC-155 alarms RIC-155 Alarms and WarningsNumber Terminal Message Description RIC-155 EventsTroubleshooting and Diagnostics Handling Alarms Table A-1. ETH and MNG-ETH Connector Pinout Appendix a Connector WiringEthernet Connectors Alarm Relay ConnectorPin Alarm Relay Function Control ConnectorTable A-2. Alarm Connector Pinout Table A-3. Control Connector PinoutMNG only Appendix B Traffic SeparationPort-Based Traffic Separation NoneLocal Mng Only Port-Based/VLAN-Based Traffic SeparationAll Uplink and Host Ports Default TaggingTable B-1. Default Tagging Modes Tagging Modes of the Bridge PortsNone Forwarding Mode Port FilterManagement Access Mode None MNG Only All Local MNG Only Internal Operation Modes of the Bridge PortsAll MNG OnlyLocal MNG Only Configuring for a Typical ApplicationManaging RIC-155 via MNG Port Figure B-9. Managing RIC-155 via MNG Port Managing RIC-155 via Data PortFigure B-10. Managing RIC-155 via Data Port Index STM-1/OC-3c interface, 1-2,1-6 RADview-Lite,3-5Excellent Good Fair Poor Very Poor Customer Response FormPage Error Report Page Page International Headquarters