RAD Data comm RIC-155 operation manual Control Connector, Table A-2. Alarm Connector Pinout

Page 74

Appendix A Connector WiringRIC-155Installation and Operation Manual

 

 

Table A-2. ALARM Connector Pinout

 

 

 

Pin

Alarm Relay

Function

 

 

 

1

Minor

Minor NO (minor alarm is OFF)

 

 

 

2

Minor

Minor NC (minor alarm is ON)

 

 

 

6

Minor

Minor COM

 

 

 

4

Major

Major NO (major alarm is OFF)

 

 

 

5

Major

Major NC (major alarm is ON)

 

 

 

9

Major

Major COM

 

 

 

7

Input alarm

Exernal alarm (input)

 

 

 

8

Input alarm

External alarm (input)

 

 

 

A.3 Control Connector

The terminal interface of RIC-155 terminates in a 9-pin female connector, designated CONTROL. Table A-3lists the pinout of the CONTROL connector.

Table A-3. CONTROL Connector Pinout

Pin

Pin Name

Direction

Description

 

 

 

 

3

TXD

Output

TXD data to terminal

 

 

 

 

4

DTR

Output

DTR data terminal ready

 

 

 

 

2

RXD

Input

RXD data from terminal

 

 

 

 

5

GND

Output

Ground

 

 

 

 

1

DCD

Input

DCD input control from terminal

 

 

 

 

7

RTS

Output

RTS output command to terminal

 

 

 

 

8

CTS

Input

CTS input command from terminal

 

 

 

 

6

DSR

Input

Not used

 

 

 

 

9

RI

Input

Not used

 

 

 

 

A-2

Control Connector

Image 74
Contents RIC-155 Page RIC-155 Limited Warranty General Safety Instructions Please observe the following precautionsConnection of DC Mains General Safety PracticesConnection of AC Mains Ports Safety Status Connection of Data and Telecommunications CablesElectromagnetic Compatibility EMC Canadian Emission Requirements ConventionsProduct Name SafetyManufacturers Name Manufacturers Address Supplementary InformationQuick Start Guide Installing RIC-155Configuring RIC-155 Configuring RIC-155 To configure RIC-155Contents Troubleshooting and Diagnostics Appendix A. Connector Wiring Appendix B. Traffic SeparationVersions Chapter IntroductionOverview ApplicationSTM-1/OC-3c Interface Features10/100BaseT Interface Fiber Optic Interface OptionsInternal Bridge Alarm RelayManagement Status ReportingPhysical Description RIC-155 3D ViewRIC-155 Block Diagram Functional DescriptionTechnical Specifications Alarm Types Major and minor Connector DB-9, female Temperature 50C / 32-122F Humidity Up to 90%, non-condensingIntroduction Site Requirements and Prerequisites Chapter Installation and SetupIntroduction Package Contents Connecting the Interface CablesConnecting DC Power Connecting the Power CableConnecting AC Power Connecting the Power Cable Turning On RIC-155 Controls and IndicatorsChapter Operation To turn on RIC-155RIC-155 LEDs RIC-155 Normal Indicator StatusIndicator Status Name Function LocationDefault Settings RIC-155 Default SettingsManaging RIC-155 via Terminal Port Configuration AlternativesParameter Default Value UplinkStarting Terminal Session for a First Time Managing RIC-155 via Ethernet PortsPreparing the Terminal To prepare RIC-155 for network managementTo start a ConfiguRAD session Navigating the Management Menus Loging onTo enter the user name and password Menu MapCorrecting Entries To choose an option ConfiguRAD sessionChoosing Options To choose an option terminal sessionLogging Out Turning Off RIC-155Navigating Tables Operation Turning Off RIC-155 To access the Configuration menu Chapter ConfigurationConfiguring RIC-155 for Management To access the Management menuEntering Device Information To enter device informationConfiguring the Host Parameters To define the IP parametersConfiguring the Network Managers To configure the network managersControlling the Management Access To define the management access methodConfiguring the RIC-155 for Operation To enable or disable management portsConfiguring the Clock Source Configuring Control Port ParametersChanging the Control Port Data Rate Enabling and Disabling Pop-up AlarmsConfiguring the Security Timeout Configuring the STM-1/OC-3c Interface Configuring the Physical PortsConfiguring the Ethernet Interface J1 Path Trace 10E-3,10E-4,10E-510E-5,10E-6,10E-7,10E-8,10E-9 Line Signal Degraded Error Uplink Port Signal LossLine Excessive Error Defect Uplink Port Loss of SignalTo configure the Fast Ethernet bridge Configuring the Internal BridgeConfiguring Fast Ethernet Bridge Mbps, 8 Mbps, No LimitTo access the Bridge Port menu Configuring the Bridge PortsConfiguring Ethernet Management and Data Bridge Ports To configure the Ethernet management and data bridge portsConfiguring the POS Bridge Port To configure the POS portTo display the system information Displaying the RIC-155 StatusDisplaying the System Status To display the Ethernet port status Displaying the Port StatusDisplaying the Ethernet Port Status To display the STM-1/OC-3c port status Displaying the STM-1/OC-3c Port StatusDATA/MNG Port Status Parameters Parameters ValuesAdditional Tasks Changing the PasswordTo change the current password STM-1/OC-3c Port Status Parameters21. User Access Menu Displaying the RIC-155 InventoryTo install a new software release via Tftp Installing Software ReleasesInstalling a New Software Release via Tftp Installing a New Software Release via Xmodem To install a new software release via XmodemTo download a configuration file Transferring Configuration FilesTo upload a configuration file Displaying the Software VersionTo switch software versions Switching Software VersionsResetting RIC-155 To reset RIC-155 to the defaults Resetting RIC-155 to Factory DefaultsResetting RIC-155 To reset RIC-155Displaying the Ethernet Statistics Chapter Troubleshooting DiagnosticsMonitoring Performance To display the Ethernet statisticsDisplaying SDH/SONET Statistics To display the current SDH/SONET statisticsUplink Statistics Screen, Display Description RangeUasl RCV Abort To display SDH/SONET statistics for all intervals 1explains all SDH/SONET statistics parametersPower-Up Self-Test Detecting ErrorsHandling Alarms Front Panel LEDsWorking with the Log File Displaying System AlarmsTo display the system alarms To display the event log fileTo clear the event log Configuring Alarm SeverityTo configure the alarm severity RIC-155 Alarms and Warnings Masking Port AlarmsTo mask RIC-155 alarms Terminal Message Description SeverityRIC-155 Events Number Terminal Message DescriptionTroubleshooting and Diagnostics Handling Alarms Alarm Relay Connector Appendix a Connector WiringEthernet Connectors Table A-1. ETH and MNG-ETH Connector PinoutTable A-3. Control Connector Pinout Control ConnectorTable A-2. Alarm Connector Pinout Pin Alarm Relay FunctionNone Appendix B Traffic SeparationPort-Based Traffic Separation MNG onlyLocal Mng Only Port-Based/VLAN-Based Traffic SeparationAll Tagging Modes of the Bridge Ports Default TaggingTable B-1. Default Tagging Modes Uplink and Host PortsInternal Operation Modes of the Bridge Ports Forwarding Mode Port FilterManagement Access Mode None MNG Only All Local MNG Only NoneMNG Only AllLocal MNG Only Configuring for a Typical ApplicationManaging RIC-155 via MNG Port Managing RIC-155 via Data Port Figure B-9. Managing RIC-155 via MNG PortFigure B-10. Managing RIC-155 via Data Port Index RADview-Lite,3-5 STM-1/OC-3c interface, 1-2,1-6Customer Response Form Excellent Good Fair Poor Very PoorPage Error Report Page Page International Headquarters