RAD Data comm RIC-155 10E-3,10E-4,10E-5, 10E-5,10E-6,10E-7,10E-8,10E-9, J1 Path Trace

Page 46

Chapter 4 Configuration

RIC-155Installation and Operation Manual

 

 

Uplink Mode, uplink operation mode

SDH

SONET

BER Threshold, controls activation of the Line BER SD and EED Enable, the EED and SD statistics data is collected Disable, the EED and SD statistics data is not collected

EED Threshold, Excessive Error Defect threshold in 1E-N, where N = 3, 4 or 5. The Excessive Error Defect is detected if an equivalent BER exceeds selected EED threshold. The Excessive Error Defect is cleared if the equivalent BER is better then 1E-(EED + 1).

10E-3,10E-4,10E-5

SD Threshold, Degraded Signal Defect threshold in 1E-N, where N = 5, 6, 7, 8 or 9. The Degraded Signal Defect is detected if an equivalent BER exceeds selected SD threshold. The Degraded Signal Defect is cleared if the equivalent BER is better then 1E-(SD + 1).

10E-5,10E-6,10E-7,10E-8,10E-9

J1 Path Trace Configuration controls the insertion of a user-defined test string (trace) into the transmit path (J1 byte). A second menu opens to define the following:

Enable/Disable, transmit path trace insertion is enabled or disabled

Actual Rx Path Trace, specifies the format of the path trace (up to 62 characters for SONET and up to 15 characters for SDH)

Tx Path Trace, transmit test string Rx Path Trace, receive test string Padding, select spaces or nulls.

Note Both sites must be configured the in the same manner.

J1 Path Trace.

Physical Failure Forwarding specifies whether the Ethernet traffic is interrupted if an STM-1/OC-3c uplink failure is detected.

Enable the Ethernet traffic is interrupted if an STM-1/OC-3c uplink failure is detected

Disable the Ethernet traffic is not interrupted if an STM-1/OC-3c uplink failure is detected.

4-10 Configuring the Physical Ports

Image 46
Contents RIC-155 Page RIC-155 Limited Warranty General Safety Instructions Please observe the following precautionsConnection of AC Mains General Safety PracticesConnection of DC Mains Ports Safety Status Connection of Data and Telecommunications CablesElectromagnetic Compatibility EMC Canadian Emission Requirements ConventionsProduct Name SafetyManufacturers Name Manufacturers Address Supplementary InformationConfiguring RIC-155 Installing RIC-155Quick Start Guide Configuring RIC-155 To configure RIC-155Contents Troubleshooting and Diagnostics Appendix A. Connector Wiring Appendix B. Traffic SeparationVersions Chapter IntroductionOverview ApplicationSTM-1/OC-3c Interface Features10/100BaseT Interface Fiber Optic Interface OptionsInternal Bridge Alarm RelayManagement Status ReportingPhysical Description RIC-155 3D ViewRIC-155 Block Diagram Functional DescriptionTechnical Specifications Alarm Types Major and minor Connector DB-9, female Temperature 50C / 32-122F Humidity Up to 90%, non-condensingIntroduction Introduction Chapter Installation and SetupSite Requirements and Prerequisites Package Contents Connecting the Interface CablesConnecting AC Power Connecting the Power CableConnecting DC Power Connecting the Power Cable Turning On RIC-155 Controls and IndicatorsChapter Operation To turn on RIC-155RIC-155 LEDs RIC-155 Normal Indicator StatusIndicator Status Name Function LocationDefault Settings RIC-155 Default SettingsManaging RIC-155 via Terminal Port Configuration AlternativesParameter Default Value UplinkStarting Terminal Session for a First Time Managing RIC-155 via Ethernet PortsPreparing the Terminal To prepare RIC-155 for network managementTo start a ConfiguRAD session Navigating the Management Menus Loging onTo enter the user name and password Menu MapCorrecting Entries To choose an option ConfiguRAD sessionChoosing Options To choose an option terminal sessionNavigating Tables Turning Off RIC-155Logging Out Operation Turning Off RIC-155 To access the Configuration menu Chapter ConfigurationConfiguring RIC-155 for Management To access the Management menuEntering Device Information To enter device informationConfiguring the Host Parameters To define the IP parametersConfiguring the Network Managers To configure the network managersControlling the Management Access To define the management access methodConfiguring the RIC-155 for Operation To enable or disable management portsConfiguring the Clock Source Configuring Control Port ParametersConfiguring the Security Timeout Enabling and Disabling Pop-up AlarmsChanging the Control Port Data Rate Configuring the Ethernet Interface Configuring the Physical PortsConfiguring the STM-1/OC-3c Interface 10E-5,10E-6,10E-7,10E-8,10E-9 10E-3,10E-4,10E-5J1 Path Trace Line Signal Degraded Error Uplink Port Signal LossLine Excessive Error Defect Uplink Port Loss of SignalTo configure the Fast Ethernet bridge Configuring the Internal BridgeConfiguring Fast Ethernet Bridge Mbps, 8 Mbps, No LimitTo access the Bridge Port menu Configuring the Bridge PortsConfiguring Ethernet Management and Data Bridge Ports To configure the Ethernet management and data bridge portsConfiguring the POS Bridge Port To configure the POS portDisplaying the System Status Displaying the RIC-155 StatusTo display the system information Displaying the Ethernet Port Status Displaying the Port StatusTo display the Ethernet port status To display the STM-1/OC-3c port status Displaying the STM-1/OC-3c Port StatusDATA/MNG Port Status Parameters Parameters ValuesAdditional Tasks Changing the PasswordTo change the current password STM-1/OC-3c Port Status Parameters21. User Access Menu Displaying the RIC-155 InventoryInstalling a New Software Release via Tftp Installing Software ReleasesTo install a new software release via Tftp Installing a New Software Release via Xmodem To install a new software release via XmodemTo download a configuration file Transferring Configuration FilesTo upload a configuration file Displaying the Software VersionResetting RIC-155 Switching Software VersionsTo switch software versions To reset RIC-155 to the defaults Resetting RIC-155 to Factory DefaultsResetting RIC-155 To reset RIC-155Displaying the Ethernet Statistics Chapter Troubleshooting DiagnosticsMonitoring Performance To display the Ethernet statisticsDisplaying SDH/SONET Statistics To display the current SDH/SONET statisticsUplink Statistics Screen, Display Description RangeUasl RCV Abort To display SDH/SONET statistics for all intervals 1explains all SDH/SONET statistics parametersPower-Up Self-Test Detecting ErrorsHandling Alarms Front Panel LEDsWorking with the Log File Displaying System AlarmsTo display the system alarms To display the event log fileTo configure the alarm severity Configuring Alarm SeverityTo clear the event log RIC-155 Alarms and Warnings Masking Port AlarmsTo mask RIC-155 alarms Terminal Message Description SeverityRIC-155 Events Number Terminal Message DescriptionTroubleshooting and Diagnostics Handling Alarms Alarm Relay Connector Appendix a Connector WiringEthernet Connectors Table A-1. ETH and MNG-ETH Connector PinoutTable A-3. Control Connector Pinout Control ConnectorTable A-2. Alarm Connector Pinout Pin Alarm Relay FunctionNone Appendix B Traffic SeparationPort-Based Traffic Separation MNG onlyAll Port-Based/VLAN-Based Traffic SeparationLocal Mng Only Tagging Modes of the Bridge Ports Default TaggingTable B-1. Default Tagging Modes Uplink and Host PortsInternal Operation Modes of the Bridge Ports Forwarding Mode Port FilterManagement Access Mode None MNG Only All Local MNG Only NoneMNG Only AllManaging RIC-155 via MNG Port Configuring for a Typical ApplicationLocal MNG Only Managing RIC-155 via Data Port Figure B-9. Managing RIC-155 via MNG PortFigure B-10. Managing RIC-155 via Data Port Index RADview-Lite,3-5 STM-1/OC-3c interface, 1-2,1-6Customer Response Form Excellent Good Fair Poor Very PoorPage Error Report Page Page International Headquarters