RAD Data comm RIC-155 Detecting Errors, Handling Alarms, Power-Up Self-Test, Front Panel LEDs

Page 67

RIC-155Installation and Operation ManualChapter 5 Troubleshooting and Diagnostics

Uplink Interval Statistics

 

RIC-155

 

 

 

 

 

1

RCV

XMT

RCV_ABORT

XMT ABORT

RCV_FCS

 

100

50

0

1

6

2

100

50

0

1

6

3

100

50

0

1

6

V

4

100

50

0

1

6

 

5

100

50

0

1

6

 

6

100

50

0

1

6

 

7

100

50

0

10

6

 

8

100

50

0

10

6

 

9

100

50

0

10

6

->>

ESC-prev.menu; !-main menu; &-exit;

Figure 5-8. Uplink Interval Statistics, Page 3

To clear SDH/SONET statistics:

From the Uplink Statistics, select Clear Statistics to clear all collected SDH/SONET statistic data.

Note You can also clear all Ethernet and SDH/SONET statistic data by selecting Clear All Statistics from the Physical Port Statistics menu.

5.2Detecting Errors

Power-Up Self-Test

RIC-155 performs a hardware self-test upon turn-on. The self-test sequence checks the critical circuit functions of RIC-155. If RIC-155 fails the self-test, the Self test failure alarm is stored in the alarm buffer (see Table 5-2).

Front Panel LEDs

The status of RIC-155 is indicated by the ALM LED indicator located on the front panel. For the description of the ALM LED and its functions, refer to Chapter 3.

5.3Handling Alarms

RIC-155 detects fault conditions and initiates alarms to alert the user. RIC-155 supports three alarm types:

System alarms

Information messages (warnings)

Events.

RIC-155 maintains a separate display for all active system alarms. In addition,

RIC-155 supports log file, holding up to 200 alarm entries.

Handling Alarms

5-7

Image 67
Contents RIC-155 Page RIC-155 Limited Warranty Please observe the following precautions General Safety InstructionsConnection of AC Mains General Safety PracticesConnection of DC Mains Connection of Data and Telecommunications Cables Ports Safety StatusElectromagnetic Compatibility EMC Conventions Canadian Emission RequirementsSupplementary Information SafetyManufacturers Name Manufacturers Address Product NameConfiguring RIC-155 Installing RIC-155Quick Start Guide To configure RIC-155 Configuring RIC-155Contents Appendix A. Connector Wiring Appendix B. Traffic Separation Troubleshooting and DiagnosticsApplication Chapter IntroductionOverview VersionsFiber Optic Interface Options Features10/100BaseT Interface STM-1/OC-3c InterfaceStatus Reporting Alarm RelayManagement Internal BridgeRIC-155 3D View Physical DescriptionFunctional Description RIC-155 Block DiagramTechnical Specifications Temperature 50C / 32-122F Humidity Up to 90%, non-condensing Alarm Types Major and minor Connector DB-9, femaleIntroduction Introduction Chapter Installation and SetupSite Requirements and Prerequisites Connecting the Interface Cables Package ContentsConnecting AC Power Connecting the Power CableConnecting DC Power Connecting the Power Cable To turn on RIC-155 Controls and IndicatorsChapter Operation Turning On RIC-155Name Function Location RIC-155 Normal Indicator StatusIndicator Status RIC-155 LEDsRIC-155 Default Settings Default SettingsUplink Configuration AlternativesParameter Default Value Managing RIC-155 via Terminal PortTo prepare RIC-155 for network management Managing RIC-155 via Ethernet PortsPreparing the Terminal Starting Terminal Session for a First TimeTo start a ConfiguRAD session Menu Map Loging onTo enter the user name and password Navigating the Management MenusTo choose an option terminal session To choose an option ConfiguRAD sessionChoosing Options Correcting EntriesNavigating Tables Turning Off RIC-155Logging Out Operation Turning Off RIC-155 To access the Management menu Chapter ConfigurationConfiguring RIC-155 for Management To access the Configuration menuTo enter device information Entering Device InformationTo define the IP parameters Configuring the Host ParametersTo configure the network managers Configuring the Network ManagersTo define the management access method Controlling the Management AccessTo enable or disable management ports Configuring the RIC-155 for OperationConfiguring Control Port Parameters Configuring the Clock SourceConfiguring the Security Timeout Enabling and Disabling Pop-up AlarmsChanging the Control Port Data Rate Configuring the Ethernet Interface Configuring the Physical PortsConfiguring the STM-1/OC-3c Interface 10E-5,10E-6,10E-7,10E-8,10E-9 10E-3,10E-4,10E-5J1 Path Trace Uplink Port Loss of Signal Uplink Port Signal LossLine Excessive Error Defect Line Signal Degraded ErrorMbps, 8 Mbps, No Limit Configuring the Internal BridgeConfiguring Fast Ethernet Bridge To configure the Fast Ethernet bridgeTo configure the Ethernet management and data bridge ports Configuring the Bridge PortsConfiguring Ethernet Management and Data Bridge Ports To access the Bridge Port menuTo configure the POS port Configuring the POS Bridge PortDisplaying the System Status Displaying the RIC-155 StatusTo display the system information Displaying the Ethernet Port Status Displaying the Port StatusTo display the Ethernet port status Parameters Values Displaying the STM-1/OC-3c Port StatusDATA/MNG Port Status Parameters To display the STM-1/OC-3c port statusSTM-1/OC-3c Port Status Parameters Changing the PasswordTo change the current password Additional TasksDisplaying the RIC-155 Inventory 21. User Access MenuInstalling a New Software Release via Tftp Installing Software ReleasesTo install a new software release via Tftp To install a new software release via Xmodem Installing a New Software Release via XmodemDisplaying the Software Version Transferring Configuration FilesTo upload a configuration file To download a configuration fileResetting RIC-155 Switching Software VersionsTo switch software versions To reset RIC-155 Resetting RIC-155 to Factory DefaultsResetting RIC-155 To reset RIC-155 to the defaultsTo display the Ethernet statistics Chapter Troubleshooting DiagnosticsMonitoring Performance Displaying the Ethernet StatisticsTo display the current SDH/SONET statistics Displaying SDH/SONET StatisticsDisplay Description Range Uplink Statistics Screen,Uasl RCV Abort 1explains all SDH/SONET statistics parameters To display SDH/SONET statistics for all intervalsFront Panel LEDs Detecting ErrorsHandling Alarms Power-Up Self-TestTo display the event log file Displaying System AlarmsTo display the system alarms Working with the Log FileTo configure the alarm severity Configuring Alarm SeverityTo clear the event log Terminal Message Description Severity Masking Port AlarmsTo mask RIC-155 alarms RIC-155 Alarms and WarningsNumber Terminal Message Description RIC-155 EventsTroubleshooting and Diagnostics Handling Alarms Table A-1. ETH and MNG-ETH Connector Pinout Appendix a Connector WiringEthernet Connectors Alarm Relay ConnectorPin Alarm Relay Function Control ConnectorTable A-2. Alarm Connector Pinout Table A-3. Control Connector PinoutMNG only Appendix B Traffic SeparationPort-Based Traffic Separation NoneAll Port-Based/VLAN-Based Traffic SeparationLocal Mng Only Uplink and Host Ports Default TaggingTable B-1. Default Tagging Modes Tagging Modes of the Bridge PortsNone Forwarding Mode Port FilterManagement Access Mode None MNG Only All Local MNG Only Internal Operation Modes of the Bridge PortsAll MNG OnlyManaging RIC-155 via MNG Port Configuring for a Typical ApplicationLocal MNG Only Figure B-9. Managing RIC-155 via MNG Port Managing RIC-155 via Data PortFigure B-10. Managing RIC-155 via Data Port Index STM-1/OC-3c interface, 1-2,1-6 RADview-Lite,3-5Excellent Good Fair Poor Very Poor Customer Response FormPage Error Report Page Page International Headquarters