RAD Data comm RIC-155 operation manual Navigating the Management Menus, Menu Map, Loging on

Page 33

RIC-155Installation and Operation Manual

Chapter 3 Operation

 

 

Menu Map

Note

3.5Navigating the Management Menus

This section provides a general description of the software menu operation and conventions for navigating the menus.

Figure 3-2lists all RIC-155 menus.

Figure 3-2. Menu Map

ConfiguRAD menus differ in appearance from the terminal screens, but have the same functionality.

Loging on

Note

Enter a user name and password in order to start the RIC-155 management software.

To enter the user name and password:

1.Type in USER or SU and press <Enter>.

2.Type the password (Default 1234).

RIC-155 responds to your entry with asterisks.

It is recommended to change the default password to prevent unauthorized access to RIC-155.

3.Press <Enter>.

The Main menu is displayed (see Figure 3-3).

Navigating the Management Menus

3-7

Image 33
Contents RIC-155 Page RIC-155 Limited Warranty Please observe the following precautions General Safety InstructionsGeneral Safety Practices Connection of AC MainsConnection of DC Mains Connection of Data and Telecommunications Cables Ports Safety StatusElectromagnetic Compatibility EMC Conventions Canadian Emission RequirementsManufacturers Name Manufacturers Address SafetyProduct Name Supplementary InformationInstalling RIC-155 Configuring RIC-155Quick Start Guide To configure RIC-155 Configuring RIC-155Contents Appendix A. Connector Wiring Appendix B. Traffic Separation Troubleshooting and DiagnosticsOverview Chapter IntroductionVersions Application10/100BaseT Interface FeaturesSTM-1/OC-3c Interface Fiber Optic Interface OptionsManagement Alarm RelayInternal Bridge Status ReportingRIC-155 3D View Physical DescriptionFunctional Description RIC-155 Block DiagramTechnical Specifications Temperature 50C / 32-122F Humidity Up to 90%, non-condensing Alarm Types Major and minor Connector DB-9, femaleIntroduction Chapter Installation and Setup IntroductionSite Requirements and Prerequisites Connecting the Interface Cables Package ContentsConnecting the Power Cable Connecting AC PowerConnecting DC Power Connecting the Power Cable Chapter Operation Controls and IndicatorsTurning On RIC-155 To turn on RIC-155Indicator Status RIC-155 Normal Indicator StatusRIC-155 LEDs Name Function LocationRIC-155 Default Settings Default SettingsParameter Default Value Configuration AlternativesManaging RIC-155 via Terminal Port UplinkPreparing the Terminal Managing RIC-155 via Ethernet PortsStarting Terminal Session for a First Time To prepare RIC-155 for network managementTo start a ConfiguRAD session To enter the user name and password Loging onNavigating the Management Menus Menu MapChoosing Options To choose an option ConfiguRAD sessionCorrecting Entries To choose an option terminal sessionTurning Off RIC-155 Navigating TablesLogging Out Operation Turning Off RIC-155 Configuring RIC-155 for Management Chapter ConfigurationTo access the Configuration menu To access the Management menuTo enter device information Entering Device InformationTo define the IP parameters Configuring the Host ParametersTo configure the network managers Configuring the Network ManagersTo define the management access method Controlling the Management AccessTo enable or disable management ports Configuring the RIC-155 for OperationConfiguring Control Port Parameters Configuring the Clock SourceEnabling and Disabling Pop-up Alarms Configuring the Security TimeoutChanging the Control Port Data Rate Configuring the Physical Ports Configuring the Ethernet InterfaceConfiguring the STM-1/OC-3c Interface 10E-3,10E-4,10E-5 10E-5,10E-6,10E-7,10E-8,10E-9J1 Path Trace Line Excessive Error Defect Uplink Port Signal LossLine Signal Degraded Error Uplink Port Loss of SignalConfiguring Fast Ethernet Bridge Configuring the Internal BridgeTo configure the Fast Ethernet bridge Mbps, 8 Mbps, No LimitConfiguring Ethernet Management and Data Bridge Ports Configuring the Bridge PortsTo access the Bridge Port menu To configure the Ethernet management and data bridge portsTo configure the POS port Configuring the POS Bridge PortDisplaying the RIC-155 Status Displaying the System StatusTo display the system information Displaying the Port Status Displaying the Ethernet Port StatusTo display the Ethernet port status DATA/MNG Port Status Parameters Displaying the STM-1/OC-3c Port StatusTo display the STM-1/OC-3c port status Parameters ValuesTo change the current password Changing the PasswordAdditional Tasks STM-1/OC-3c Port Status ParametersDisplaying the RIC-155 Inventory 21. User Access MenuInstalling Software Releases Installing a New Software Release via TftpTo install a new software release via Tftp To install a new software release via Xmodem Installing a New Software Release via XmodemTo upload a configuration file Transferring Configuration FilesTo download a configuration file Displaying the Software VersionSwitching Software Versions Resetting RIC-155To switch software versions Resetting RIC-155 Resetting RIC-155 to Factory DefaultsTo reset RIC-155 to the defaults To reset RIC-155Monitoring Performance Chapter Troubleshooting DiagnosticsDisplaying the Ethernet Statistics To display the Ethernet statisticsTo display the current SDH/SONET statistics Displaying SDH/SONET StatisticsDisplay Description Range Uplink Statistics Screen,Uasl RCV Abort 1explains all SDH/SONET statistics parameters To display SDH/SONET statistics for all intervalsHandling Alarms Detecting ErrorsPower-Up Self-Test Front Panel LEDsTo display the system alarms Displaying System AlarmsWorking with the Log File To display the event log fileConfiguring Alarm Severity To configure the alarm severityTo clear the event log To mask RIC-155 alarms Masking Port AlarmsRIC-155 Alarms and Warnings Terminal Message Description SeverityNumber Terminal Message Description RIC-155 EventsTroubleshooting and Diagnostics Handling Alarms Ethernet Connectors Appendix a Connector WiringAlarm Relay Connector Table A-1. ETH and MNG-ETH Connector PinoutTable A-2. Alarm Connector Pinout Control ConnectorTable A-3. Control Connector Pinout Pin Alarm Relay FunctionPort-Based Traffic Separation Appendix B Traffic SeparationNone MNG onlyPort-Based/VLAN-Based Traffic Separation AllLocal Mng Only Table B-1. Default Tagging Modes Default TaggingTagging Modes of the Bridge Ports Uplink and Host PortsManagement Access Mode None MNG Only All Local MNG Only Forwarding Mode Port FilterInternal Operation Modes of the Bridge Ports NoneAll MNG OnlyConfiguring for a Typical Application Managing RIC-155 via MNG PortLocal MNG Only Figure B-9. Managing RIC-155 via MNG Port Managing RIC-155 via Data PortFigure B-10. Managing RIC-155 via Data Port Index STM-1/OC-3c interface, 1-2,1-6 RADview-Lite,3-5Excellent Good Fair Poor Very Poor Customer Response FormPage Error Report Page Page International Headquarters