Installing Software Releases

This section presents procedures for installing new software releases into the RIC-155 units.

RIC-155 stores two software versions, each in one of two partitions of its flash memory, which also contains a boot program. The software is stored in compressed format. The active version is decompressed and loaded into the RAM on power-up. The passive software is kept for backup purposes. If the active software gets corrupted, you can swap it with the backup. By default, RIC-155 is delivered with active software only.

New software releases are distributed on diskettes as an *.img file, which is downloaded to the local RIC-155 using the TFTP or XMODEM protocol. When starting a download, RIC-155 erases the current backup and places the new software in the backup partition. When downloading is complete, the unit checks the integrity of the new software file. If it is correct, the backup and active files are swapped. The new software release becomes active and the former active software becomes the backup. If a failure occurs during downloading, the new version is erased. In this case, only one version is left stored in the flash memory.

Configuration files can be uploaded for storage and backup.

Installing a New Software Release via TFTP

To install a new software release via TFTP:

1.Follow the path: Main menu> File Utilities > SW & File Transfer > Via TFTP. The Via TFTP menu appears.

2.From the Via TFTP menu, perform the following steps:

Select TFTP File Name and enter the name of the software file (for example, ric155.img).

Select TFTP IP Server and enter the IP address of the TFTP server. 3. From the Via TFTP menu, select TFTP Command.

4-20 Additional Tasks

Image 56
Contents RIC-155 Page RIC-155 Limited Warranty General Safety Instructions Please observe the following precautionsConnection of DC Mains General Safety PracticesConnection of AC Mains Ports Safety Status Connection of Data and Telecommunications CablesElectromagnetic Compatibility EMC Canadian Emission Requirements ConventionsSafety Manufacturers Name Manufacturers AddressProduct Name Supplementary InformationQuick Start Guide Installing RIC-155Configuring RIC-155 Configuring RIC-155 To configure RIC-155Contents Troubleshooting and Diagnostics Appendix A. Connector Wiring Appendix B. Traffic SeparationChapter Introduction OverviewVersions ApplicationFeatures 10/100BaseT InterfaceSTM-1/OC-3c Interface Fiber Optic Interface OptionsAlarm Relay ManagementInternal Bridge Status ReportingPhysical Description RIC-155 3D ViewRIC-155 Block Diagram Functional DescriptionTechnical Specifications Alarm Types Major and minor Connector DB-9, female Temperature 50C / 32-122F Humidity Up to 90%, non-condensingIntroduction Site Requirements and Prerequisites Chapter Installation and SetupIntroduction Package Contents Connecting the Interface CablesConnecting DC Power Connecting the Power CableConnecting AC Power Connecting the Power Cable Controls and Indicators Chapter OperationTurning On RIC-155 To turn on RIC-155RIC-155 Normal Indicator Status Indicator StatusRIC-155 LEDs Name Function LocationDefault Settings RIC-155 Default SettingsConfiguration Alternatives Parameter Default ValueManaging RIC-155 via Terminal Port UplinkManaging RIC-155 via Ethernet Ports Preparing the TerminalStarting Terminal Session for a First Time To prepare RIC-155 for network managementTo start a ConfiguRAD session Loging on To enter the user name and passwordNavigating the Management Menus Menu MapTo choose an option ConfiguRAD session Choosing OptionsCorrecting Entries To choose an option terminal sessionLogging Out Turning Off RIC-155Navigating Tables Operation Turning Off RIC-155 Chapter Configuration Configuring RIC-155 for ManagementTo access the Configuration menu To access the Management menuEntering Device Information To enter device informationConfiguring the Host Parameters To define the IP parametersConfiguring the Network Managers To configure the network managersControlling the Management Access To define the management access methodConfiguring the RIC-155 for Operation To enable or disable management portsConfiguring the Clock Source Configuring Control Port ParametersChanging the Control Port Data Rate Enabling and Disabling Pop-up AlarmsConfiguring the Security Timeout Configuring the STM-1/OC-3c Interface Configuring the Physical PortsConfiguring the Ethernet Interface J1 Path Trace 10E-3,10E-4,10E-510E-5,10E-6,10E-7,10E-8,10E-9 Uplink Port Signal Loss Line Excessive Error DefectLine Signal Degraded Error Uplink Port Loss of SignalConfiguring the Internal Bridge Configuring Fast Ethernet BridgeTo configure the Fast Ethernet bridge Mbps, 8 Mbps, No LimitConfiguring the Bridge Ports Configuring Ethernet Management and Data Bridge PortsTo access the Bridge Port menu To configure the Ethernet management and data bridge portsConfiguring the POS Bridge Port To configure the POS portTo display the system information Displaying the RIC-155 StatusDisplaying the System Status To display the Ethernet port status Displaying the Port StatusDisplaying the Ethernet Port Status Displaying the STM-1/OC-3c Port Status DATA/MNG Port Status ParametersTo display the STM-1/OC-3c port status Parameters ValuesChanging the Password To change the current passwordAdditional Tasks STM-1/OC-3c Port Status Parameters21. User Access Menu Displaying the RIC-155 InventoryTo install a new software release via Tftp Installing Software ReleasesInstalling a New Software Release via Tftp Installing a New Software Release via Xmodem To install a new software release via XmodemTransferring Configuration Files To upload a configuration fileTo download a configuration file Displaying the Software VersionTo switch software versions Switching Software VersionsResetting RIC-155 Resetting RIC-155 to Factory Defaults Resetting RIC-155To reset RIC-155 to the defaults To reset RIC-155Chapter Troubleshooting Diagnostics Monitoring PerformanceDisplaying the Ethernet Statistics To display the Ethernet statisticsDisplaying SDH/SONET Statistics To display the current SDH/SONET statisticsUplink Statistics Screen, Display Description RangeUasl RCV Abort To display SDH/SONET statistics for all intervals 1explains all SDH/SONET statistics parametersDetecting Errors Handling AlarmsPower-Up Self-Test Front Panel LEDsDisplaying System Alarms To display the system alarmsWorking with the Log File To display the event log fileTo clear the event log Configuring Alarm SeverityTo configure the alarm severity Masking Port Alarms To mask RIC-155 alarmsRIC-155 Alarms and Warnings Terminal Message Description SeverityRIC-155 Events Number Terminal Message DescriptionTroubleshooting and Diagnostics Handling Alarms Appendix a Connector Wiring Ethernet ConnectorsAlarm Relay Connector Table A-1. ETH and MNG-ETH Connector PinoutControl Connector Table A-2. Alarm Connector PinoutTable A-3. Control Connector Pinout Pin Alarm Relay FunctionAppendix B Traffic Separation Port-Based Traffic SeparationNone MNG onlyLocal Mng Only Port-Based/VLAN-Based Traffic SeparationAll Default Tagging Table B-1. Default Tagging ModesTagging Modes of the Bridge Ports Uplink and Host PortsForwarding Mode Port Filter Management Access Mode None MNG Only All Local MNG OnlyInternal Operation Modes of the Bridge Ports NoneMNG Only AllLocal MNG Only Configuring for a Typical ApplicationManaging RIC-155 via MNG Port Managing RIC-155 via Data Port Figure B-9. Managing RIC-155 via MNG PortFigure B-10. Managing RIC-155 via Data Port Index RADview-Lite,3-5 STM-1/OC-3c interface, 1-2,1-6Customer Response Form Excellent Good Fair Poor Very PoorPage Error Report Page Page International Headquarters