Chapter 6:
Setting Configuration Parameters
The
ExtendView is the recommended method for setting configuration parameters. However, regardless of the method to access the configuration parameters, the method for modifying the parameters is virtually identical.
Factory Default Settings
Table 19 displays the configuration parameter descriptions and settings with the default settings indicated in a separate column.
Table 19 Factory Default Settings
Parameter | Description | Settings | Default Setting |
|
|
|
|
Character | Bits per character | 7, 8 | 8 |
|
|
|
|
Flow | Flow control | None, Xon, Xoff, | None |
|
| CTS/RTS |
|
|
|
|
|
Parity | Parity | None, Even, Odd, Mark, | None |
|
| Space |
|
|
|
|
|
Speed | Baud rate of bits per second | 300, 600,1200, 2400, | 9600 |
|
| 3600, 4800, 7200, | 115200 – console |
|
| 9600, 14400,19200, | |
|
| port default | |
|
| 38400, 57600, 76800, | |
|
|
| |
|
| 115200, 230400, |
|
|
| 460800, 921600 |
|
|
|
|
|
Stop | Stop bits per character | 1, 2 | 1 |
|
|
|
|
Mode | Line mode or serial port protocol | 232, 422, 485, 485HD, | 232 |
|
| Disabled |
|
|
|
|
|
Ecable | Enable, Disable | Disable | |
|
|
|
|
Ecaddr | Set by user | N/A | |
|
|
|
|
Econn | 30 seconds | ||
|
|
|
|
|
|
|
|
| silex |