Parameter

Specifications

 

 

Data Rate

54 Mbps with fallback rates of 48, 36, 24, 18, 12, 11, 9, 6, 5.5, 2, and 1

 

Mbps

 

 

Security

WEP Encryption: 64/128 bits

 

TKIP, AES

 

 

Media Access Protocol

Carrier Sense Multiple Access with Collision Avoidance (CSMA/CA)

 

with ACK architecture, 32 bits MAC-layer.

 

 

Antenna Connector Type

2 SMT ultra-miniature coaxial connectors

 

 

Operating Voltage

3.3 VDC ± 5%

 

 

Bus Interface

Proprietary 70-Pin

 

 

Antenna Port Impedance

50 ohm

 

 

Channel Switching Speed

260 sec

 

 

LO Settling Time

61 sec

 

 

Receiver Noise Figure

6.0/6.7 dB (typ/max) 2.4Ghz

 

9.2/9.6 dB (typ/max) 5Ghz

Transmit Output Power (Production Specification)

Test Conditions: Supply Voltage (Vcc) = 3.3V, Ambient Temperature = 25ºC

 

Frequency Range

Modulation

Minimum

Typical

Maximum

 

 

(Bands)

Rate

Output

Output

Output

 

 

 

 

Power

Power

Power

 

 

 

 

(dBm)

(dBm)

(dBm)

 

 

 

 

 

 

 

 

 

Transmitter Power

1 Mbps

14

15.5

20.5

 

 

 

 

 

 

 

 

 

Output low band

2 Mbps

14

15.5

20.5

 

 

(802.11b)

 

 

 

 

 

 

5.5 Mbps

14

15.5

20.5

 

 

 

 

 

 

 

 

 

 

11 Mbps

14

15.5

20.5

 

 

 

 

 

 

 

 

 

Transmitter Power

6 Mbps

15.5

17

21.5

 

 

 

 

 

 

 

 

 

Output low band

9 Mbps

15.5

17

21.5

 

 

(802.11g)

 

 

 

 

 

 

12 Mbps

14

15.6

20

 

 

 

 

 

 

 

 

 

 

18 Mbps

14

15.6

20

 

 

 

 

 

 

 

 

 

 

24Mbps

13

14.3

19

 

 

 

 

 

 

 

 

 

 

36 Mbps

13

14.3

19

 

 

 

 

 

 

 

 

 

 

48 Mbps

10

11.6

16

 

 

 

 

 

 

 

 

 

 

54 Mbps

10

11.6

16

 

 

 

 

 

 

 

 

 

Transmitter

6 Mbps

15

16.1

21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Designing with the SX-550

 

silex

 

Page 53

 

 

Part Number 40183-101

 

 

 

Image 59
Contents Developer’s Reference Guide Trademarks Contents Configuring Serial Port Monitor Alert and Trap Configuration Figures Silex Contents Part Number Emissions Disclaimer Safety PrecautionsAbout This Reference Guide Silex About This Reference Guide Part Number Introduction Processor and Wireless LAN Radio PCBSilex Introduction Part Number Chapter Getting Started Installing Wlan Module in DaughtercardVerify Development Kit Contents Wlan Module Inserted in Daughtercard Installing the SX-550 Wlan ModuleSX-550 Evaluation Daughtercard Status Monitors Function State Monitoring Module StatusFunction State Status OEM Interface Pinout SignalOEM Interface OEM Interface Signal Description Pin Type Serial Peripheral Interface Electrical CharacteristicsPower Input Power ManagementSerial Ports Logical Serial Port Signal Descriptions Pin Input/OutputGround General Purpose IO General Purpose IO Signal Descriptions Pin SelectableGPIO1 GPIO2 GPIO3 GPIO4 GPIO5 GPIO6 GPIO7 LEDs and General Purpose IO SignalsEvaluation CN210 Drive High/Low Description Daughtercard LED and Gpio DescriptionsRS-232 Cable Additional OEM Interface SignalsUART0TXD, UART0RTS UART1TXD, UART1RTS OEM Interface Electrical CharacteristicsEvaluation Module Connections Chapter Using the SX-550 Wlan ModuleUsing the Wireless Method Port Settings Parameter Access silex Console InterfaceUsing the Wired Ethernet Method Action Result Generating Configuration DataPushbutton Functions Silex Using the SX-550 Wlan Module Part Number Access ExtendView Utility Chapter Accessing Configuration ParametersInstalling ExtendView Utility ExtendView Main Using ExtendView UtilityCreate View with Default Settings ExtendView Configuration Window Access Http PagesSX-550 Home Access Internal Command ConsoleTelnet Where x.x.x.x is the IP address of the SX-550 module Using Telnet SessionUsing Terminal Emulator through the Serial Port Standard AT Commands Supported Using AT Modem CommandsAT Commands Parameter Description AT#Cset nw ssid silex#Csave Parameter Command DescriptionExtended AT Commands Parameter Description Response CodesCTS/RTS Chapter Setting Configuration ParametersFactory Default Settings Factory Default Settings Parameter DescriptionParameter Description Settings Default Setting Modify Basic SettingsRestoring Factory Default Settings Changing Serial SettingsParameter Setting Serial Setting ParametersTCP/IP Window Modifying TCP/IP SettingsChange Password Window TCP/IP SettingsDNS TCP/IP Configuration Settings ParameterCommand Description Configure Simple Network Management ProtocolSnmp Commands Snmp Trap Settings Parameter Configuring Gpio Alerts and TrapsSET Gpio DIR in OUT Gpio # Gpio Commands DescriptionShow Gpio DIR SET Gpio Special ENA/DIS Gpio Trigger Commands DescriptionShow Gpio Special Trig # Email String Your email text msg here Gpio #2 is Gpio Transmit Commands DescriptionTrig # Email String Gpio #1 is Gpio #2 is Index # Monitor String Port Monitor Alert Commands DescriptionShow Port S1 Trigmon Index # Xmit String Trigger string was seen Trigmon Commands DescriptionShow Port S1 Trigxmt Index # Xmit StringOEM Header Interface OEM Header Interface Pinout SignalDesigning with the SX-550 Differential Output Ethernet Transmit Data primary Antenna Connectors Ethernet PHY Transformer SpecificationGTS General Purpose I/O Interface10/100M Magnetics Manufacturers Part Number YCL40-Pin Drive High/Low Description PowerRadio Performance Specifications Parameter Chapter Product SpecificationsProduct Specifications Component SpecificationsTKIP, AES Parameter SpecificationsReceiver Sensitivity Production Specification Port Destination Device TCP Port ConnectionsTCP Port Connections SET NW AUTHtype Open Shared Ttls Leap WPA-PSK Appendix a Console CommandsWireless and Network Security Commands Network Commands DescriptionSET NW KEY# SET NW ENCSET NW RTS SET NW CERTCN2 SET NW CertcnName User defined Common nameSET NW PW SET NW CertexpSET NW Certkey SET NW IDSET NW Wpagroup Enable Disable CL Port S1 JOB Port CommandsPort Commands Description XON/XOFF RS232SET Snmp Getcomm Server Information CommandsServer Information Commands Description Sample Output SET Port S1 Stop 1SET Snmp LOCation string Command Description Sample OutputSnmp is Enabled Serial server Firmware Ver .19 Boot Ver 16Mbit FlashService Commands Description Service CommandsSET Servi service name NAme Newname SET Servi service name FRMSET Servi service name FRS SET Servi service name IP ENable DIsablePOSTSCRIPT\0A String CommandsString Commands Description Enter LANGUAGE=TCP/IP Commands Description TCP/IP CommandsSET IP LPD Auto Bootp Rarp Dhcp StaticSET IP FTP SET IP HttpSET IP Tftp SET IP TCPFirmware Update Command Description Power Configuration CommandsFirmware Update Power Configuration Command DescriptionSET LOAd IP Aa.bb.cc.dd SET LOAd ENable DIsableFirmware load is disabled SET LOAd HOst NameMiscellaneous Commands Miscellaneous CommandsHelp Commands Appendix B Engineering Drawings Antenna Cable AssemblyElectrical Specifications for Antenna Vswr Electrical Specifications Parameter ValueSilex technology america, Inc