Silex technology SX-550 manual Access silex Console Interface, Using the Wired Ethernet Method

Page 26

￿

Using the Wired Ethernet Method

To use wired Ethernet method:

1.Connect the Ethernet cable to the RJ-45 jack. This disables the wireless card.

2.Connect the power supply plug to the SX-550 Evaluation Daughtercard.

3.Power on the power supply.

When a link is established, the yellow and green LEDs on the module should begin blinking.

4.Continue to the Access silex Console Interface section.

Access silex Console Interface

You can access the silex Console Interface using a terminal program, such as Windows HyperTerminal.

To access HyperTerminal:

1.On a Windows computer, click START and select Programs>Accessories>Communications>HyperTerminal. The Connection Description window displays.

2.Type any name for the connection, then click OK. The Connect To window displays.

3.In the Connect Using list box, select a connection, then click OK. The default is COM1. The COM Properties window displays.

4.On the Port Settings tab, select the settings shown in Table 12, then click OK.

Table 12 Port Settings

Parameter

Setting

Bits per Second

115200

 

 

Data Bits

8

 

 

Parity

None

 

 

Stop Bits

1

 

 

Flow Control

None

 

 

5.Press Return until the Local> prompt displays. No user name is necessary.

Now you are ready to enter console commands. For a list of the console commands, refer to Appendix A:

Console Commands

Page 20

silex

Using the SX-550 WLAN Module

 

Part Number 40183-101

 

Image 26
Contents Developer’s Reference Guide Trademarks Contents Configuring Serial Port Monitor Alert and Trap Configuration Figures Silex Contents Part Number Emissions Disclaimer Safety PrecautionsAbout This Reference Guide Silex About This Reference Guide Part Number Processor and Wireless LAN Radio PCB IntroductionSilex Introduction Part Number Installing Wlan Module in Daughtercard Chapter Getting StartedVerify Development Kit Contents Installing the SX-550 Wlan Module Wlan Module Inserted in DaughtercardSX-550 Evaluation Daughtercard Monitoring Module Status Status Monitors Function StateFunction State Status OEM Interface Pinout SignalOEM Interface OEM Interface Signal Description Pin Type Power Management Electrical CharacteristicsPower Input Serial Peripheral InterfaceLogical Serial Port Signal Descriptions Pin Input/Output Serial PortsGround General Purpose IO Signal Descriptions Pin Selectable General Purpose IOLED and Gpio Descriptions LEDs and General Purpose IO SignalsEvaluation CN210 Drive High/Low Description Daughtercard GPIO1 GPIO2 GPIO3 GPIO4 GPIO5 GPIO6 GPIO7Additional OEM Interface Signals RS-232 CableOEM Interface Electrical Characteristics UART0TXD, UART0RTS UART1TXD, UART1RTSEvaluation Module Connections Chapter Using the SX-550 Wlan ModuleUsing the Wireless Method Port Settings Parameter Access silex Console InterfaceUsing the Wired Ethernet Method Action Result Generating Configuration DataPushbutton Functions Silex Using the SX-550 Wlan Module Part Number Chapter Accessing Configuration Parameters Access ExtendView UtilityInstalling ExtendView Utility Using ExtendView Utility ExtendView MainCreate View with Default Settings Access Http Pages ExtendView Configuration WindowAccess Internal Command Console SX-550 HomeTelnet Where x.x.x.x is the IP address of the SX-550 module Using Telnet SessionUsing Terminal Emulator through the Serial Port Using AT Modem Commands Standard AT Commands SupportedAT Commands Parameter Description Response Codes Parameter Command DescriptionExtended AT Commands Parameter Description AT#Cset nw ssid silex#CsaveFactory Default Settings Parameter Description Chapter Setting Configuration ParametersFactory Default Settings CTS/RTSChanging Serial Settings Modify Basic SettingsRestoring Factory Default Settings Parameter Description Settings Default SettingSerial Setting Parameters Parameter SettingModifying TCP/IP Settings TCP/IP WindowTCP/IP Settings Change Password WindowTCP/IP Configuration Settings Parameter DNSCommand Description Configure Simple Network Management ProtocolSnmp Commands Configuring Gpio Alerts and Traps Snmp Trap Settings ParameterSET Gpio DIR in OUT Gpio # Gpio Commands DescriptionShow Gpio DIR SET Gpio Special ENA/DIS Gpio Trigger Commands DescriptionShow Gpio Special Trig # Email String Your email text msg here Gpio #2 is Gpio Transmit Commands DescriptionTrig # Email String Gpio #1 is Gpio #2 is Index # Monitor String Port Monitor Alert Commands DescriptionShow Port S1 Trigmon Index # Xmit String Trigmon Commands DescriptionShow Port S1 Trigxmt Index # Xmit String Trigger string was seenOEM Header Interface OEM Header Interface Pinout SignalDesigning with the SX-550 Differential Output Ethernet Transmit Data primary Antenna Connectors Transformer Specification Ethernet PHYYCL General Purpose I/O Interface10/100M Magnetics Manufacturers Part Number GTSPower 40-Pin Drive High/Low DescriptionComponent Specifications Chapter Product SpecificationsProduct Specifications Radio Performance Specifications ParameterParameter Specifications TKIP, AESReceiver Sensitivity Production Specification Port Destination Device TCP Port ConnectionsTCP Port Connections Network Commands Description Appendix a Console CommandsWireless and Network Security Commands SET NW AUTHtype Open Shared Ttls Leap WPA-PSKSET NW ENC SET NW KEY#SET NW RTS Common name SET NW CertcnName User defined SET NW CERTCN2SET NW ID SET NW CertexpSET NW Certkey SET NW PWSET NW Wpagroup Enable Disable XON/XOFF RS232 Port CommandsPort Commands Description CL Port S1 JOBSET Port S1 Stop 1 Server Information CommandsServer Information Commands Description Sample Output SET Snmp GetcommSerial server Firmware Ver .19 Boot Ver 16Mbit Flash Command Description Sample OutputSnmp is Enabled SET Snmp LOCation stringService Commands Service Commands DescriptionSET Servi service name IP ENable DIsable SET Servi service name FRMSET Servi service name FRS SET Servi service name NAme NewnameEnter LANGUAGE= String CommandsString Commands Description POSTSCRIPT\0ATCP/IP Commands TCP/IP Commands DescriptionSET IP Http Auto Bootp Rarp Dhcp StaticSET IP FTP SET IP LPDSET IP TCP SET IP TftpPower Configuration Command Description Power Configuration CommandsFirmware Update Firmware Update Command DescriptionSET LOAd HOst Name SET LOAd ENable DIsableFirmware load is disabled SET LOAd IP Aa.bb.cc.ddMiscellaneous Commands Miscellaneous CommandsHelp Commands Antenna Cable Assembly Appendix B Engineering DrawingsElectrical Specifications for Antenna Electrical Specifications Parameter Value VswrSilex technology america, Inc