Figure 17 Serial Settings Window

3. Configure the serial settings, as defined in Table 20.

 

Table 20 Serial Setting Parameters

 

 

Parameter

Setting

 

 

Mode

Sets the line mode or serial port protocol.

 

RS-232 provides an interface between data terminal equipment and

 

data communications equipment employing serial binary data

 

interchange over a wired connection with a maximum range of 50

 

feet (16.5 meters).

 

RS-422 provides a data transmission system using balanced

 

differential signals or voltages to send serial binary data over a

 

wired connection with a maximum range of 4,000 feet (1.2 km).

 

Sets the line mode or serial port protocol.

 

Values are:

 

232 (default), 422, Disabled

Character Bits

Sets the bits per character

 

Values are:

 

8 (default), 7

Parity

Sets parity checking to detect any errors in transmission.

 

Values are:

 

None (default), Even, Odd, Mark, Space

Speed

Sets the baud rate for measuring for data transmission speed

 

Values are:

 

9600 (default), 115200 (console port default) 300, 600,1200, 2400,

 

3600, 4800, 7200, 14400,19200, 38400, 57600, 76800, 230400,

 

460800, 921600

Setting Configuration Parameters

silex

Page 35

 

Part Number 40183-101

 

Image 41
Contents Developer’s Reference Guide Trademarks Contents Configuring Serial Port Monitor Alert and Trap Configuration Figures Silex Contents Part Number Emissions Disclaimer Safety PrecautionsAbout This Reference Guide Silex About This Reference Guide Part Number Introduction Processor and Wireless LAN Radio PCBSilex Introduction Part Number Chapter Getting Started Installing Wlan Module in DaughtercardVerify Development Kit Contents Wlan Module Inserted in Daughtercard Installing the SX-550 Wlan ModuleSX-550 Evaluation Daughtercard Status Monitors Function State Monitoring Module StatusFunction State Status OEM Interface Pinout SignalOEM Interface OEM Interface Signal Description Pin Type Power Input Electrical CharacteristicsPower Management Serial Peripheral InterfaceSerial Ports Logical Serial Port Signal Descriptions Pin Input/OutputGround General Purpose IO General Purpose IO Signal Descriptions Pin SelectableEvaluation CN210 Drive High/Low Description Daughtercard LEDs and General Purpose IO SignalsLED and Gpio Descriptions GPIO1 GPIO2 GPIO3 GPIO4 GPIO5 GPIO6 GPIO7RS-232 Cable Additional OEM Interface SignalsUART0TXD, UART0RTS UART1TXD, UART1RTS OEM Interface Electrical CharacteristicsEvaluation Module Connections Chapter Using the SX-550 Wlan ModuleUsing the Wireless Method Port Settings Parameter Access silex Console InterfaceUsing the Wired Ethernet Method Action Result Generating Configuration DataPushbutton Functions Silex Using the SX-550 Wlan Module Part Number Access ExtendView Utility Chapter Accessing Configuration ParametersInstalling ExtendView Utility ExtendView Main Using ExtendView UtilityCreate View with Default Settings ExtendView Configuration Window Access Http PagesSX-550 Home Access Internal Command ConsoleTelnet Where x.x.x.x is the IP address of the SX-550 module Using Telnet SessionUsing Terminal Emulator through the Serial Port Standard AT Commands Supported Using AT Modem CommandsAT Commands Parameter Description Extended AT Commands Parameter Description Parameter Command DescriptionResponse Codes AT#Cset nw ssid silex#CsaveFactory Default Settings Chapter Setting Configuration ParametersFactory Default Settings Parameter Description CTS/RTSRestoring Factory Default Settings Modify Basic SettingsChanging Serial Settings Parameter Description Settings Default SettingParameter Setting Serial Setting ParametersTCP/IP Window Modifying TCP/IP SettingsChange Password Window TCP/IP SettingsDNS TCP/IP Configuration Settings ParameterCommand Description Configure Simple Network Management ProtocolSnmp Commands Snmp Trap Settings Parameter Configuring Gpio Alerts and TrapsSET Gpio DIR in OUT Gpio # Gpio Commands DescriptionShow Gpio DIR SET Gpio Special ENA/DIS Gpio Trigger Commands DescriptionShow Gpio Special Trig # Email String Your email text msg here Gpio #2 is Gpio Transmit Commands DescriptionTrig # Email String Gpio #1 is Gpio #2 is Index # Monitor String Port Monitor Alert Commands DescriptionShow Port S1 Trigmon Show Port S1 Trigxmt Trigmon Commands DescriptionIndex # Xmit String Index # Xmit String Trigger string was seenOEM Header Interface OEM Header Interface Pinout SignalDesigning with the SX-550 Differential Output Ethernet Transmit Data primary Antenna Connectors Ethernet PHY Transformer Specification10/100M Magnetics Manufacturers Part Number General Purpose I/O InterfaceYCL GTS40-Pin Drive High/Low Description PowerProduct Specifications Chapter Product SpecificationsComponent Specifications Radio Performance Specifications ParameterTKIP, AES Parameter SpecificationsReceiver Sensitivity Production Specification Port Destination Device TCP Port ConnectionsTCP Port Connections Wireless and Network Security Commands Appendix a Console CommandsNetwork Commands Description SET NW AUTHtype Open Shared Ttls Leap WPA-PSKSET NW KEY# SET NW ENCSET NW RTS Name User defined SET NW CertcnCommon name SET NW CERTCN2SET NW Certkey SET NW CertexpSET NW ID SET NW PWSET NW Wpagroup Enable Disable Port Commands Description Port CommandsXON/XOFF RS232 CL Port S1 JOBServer Information Commands Description Sample Output Server Information CommandsSET Port S1 Stop 1 SET Snmp GetcommSnmp is Enabled Command Description Sample OutputSerial server Firmware Ver .19 Boot Ver 16Mbit Flash SET Snmp LOCation stringService Commands Description Service CommandsSET Servi service name FRS SET Servi service name FRMSET Servi service name IP ENable DIsable SET Servi service name NAme NewnameString Commands Description String CommandsEnter LANGUAGE= POSTSCRIPT\0ATCP/IP Commands Description TCP/IP CommandsSET IP FTP Auto Bootp Rarp Dhcp StaticSET IP Http SET IP LPDSET IP Tftp SET IP TCPFirmware Update Power Configuration CommandsPower Configuration Command Description Firmware Update Command DescriptionFirmware load is disabled SET LOAd ENable DIsableSET LOAd HOst Name SET LOAd IP Aa.bb.cc.ddMiscellaneous Commands Miscellaneous CommandsHelp Commands Appendix B Engineering Drawings Antenna Cable AssemblyElectrical Specifications for Antenna Vswr Electrical Specifications Parameter ValueSilex technology america, Inc