Silex technology SX-560 manual Appendix D Firmware Update Procedures

Page 101

Appendix D

Firmware Update Procedures

Occasionally it may be necessary to update the SX-560 to take advantage of new features or to fix specific problems. The simplest way to perform this update is with the Silex UpdateIP utility for Windows XP and 2000 computers. This utility can be found on the CD-ROM that is included with the SX-560, or it can be downloaded from the Support & Downloads section of the Silex website (www.silexamerica.com).

To use UpdateIP:

1.Download the appropriate firmware update file from the Support & Download section of the Silex website (www.silexamerica.com) into a directory on your computer.

2.Download or copy the UpdateIP software files into a directory on your computer.

3.Double click the updateip.exe icon to start the UpdateIP application.

Important: Make sure that the UpdateIP application is included as an exception if you have a firewall enabled on your PC.

4.Click OK when you get the About Update for TCP/IP splash screen

5.When you get the Select Update File screen, locate the firmware update file that you downloaded in step 1, and double click on the file name.

6.You will get the Update Files screen. The firmware update file that you selected should appear on this screen. Click OK.

7.The program will search the local network for SX-560s. Click OK when the search process is complete.

8.A list of available SX-560s will appear. Highlight the SX-560(s) that you wish to update.

9.From the menu bar, select Update and then Start to update the SX-560(s).

If you do not have a Windows XP or 2000 system, you can use the following method to update the SX-

560firmware:

1.Download the appropriate firmware update file from the Support & Downloads Section of the Silex website (www.silexamerica.com) into a directory on your computer.

2.Enter the following command from the command line of your operating system:

tftp -iipaddress put filename access

Firmware Update Procedures

Silex

Part Number 140-00192-100

Page 95

Image 101 Silex technology SX-560 manual Appendix D Firmware Update Procedures, Tftp -iipaddress put filename access
Contents SX-560 Embedded Intelligent Module Trademarks Contents 101 Figures Silex Part Number Contents Emissions Disclaimer Safety PrecautionsAbout This Reference Guide Silex SX-560 top and bottom view IntroductionSilex Part Number Introduction Installing SX-560 Module in Evaluation Daughtercard Chapter Installing the Evaluation DaughtercardSilex Part Number Installing the Evaluation Daughtercard Verify Development Kit Contents SX-560 Module Inserted in Daughtercard Installing the SX-560 ModuleOEM Interface Monitoring Module StatusStatus Monitors Function State StatusOEM Interface Signal Descriptions Pin Type Electrical CharacteristicsRXD DCDTXD DTRLogical Serial Port 1 Signal Descriptions Pin Input/Output DB-9 RS-232 Signal TypeRTS CTSGPIO4 DTR0 GPIO3 TspicsGPIO5 DSR0 GPIO6 DCD026-Pin I/O Header Signal Selectable LED and Gpio Descriptions USB Host Port and Ethernet Port UART0TXD, UART0RTS UART1TXD, UART1RTS UART2TXD LCD InterfaceSilex Part Number Installing the Evaluation Daughtercard Basic Configuration Requirements Chapter Configuring the SX-560TCP/IP Settings Wireless Configuration SettingsConfiguration Methods Initial Wireless SetupConfiguring the SX-560 Silex Part Number Silex Configuring the SX-560 Silex Part Number Silex Using the SX-560 Configuring the SX-560 Silex Part Number Using a Web Browser to Configure the SX-560 Configuring the SX-560 Silex Part Number Using the Internal Command Console to Configure the SX-560 AD-HOC Init Exit SpaceCustomizing the SX-560 User Interface Chapter Using the SX-560 with Your ApplicationLinux Programmability SET Default Power ConfigurationSerial Port Emulator InitTelnet ipaddress portnumber Raw TCP connectionRFC 2217 Remote Modem Control Support ECable ModeSET Port S1 Constr ++++ Print Server ModeConsole Mode Switching SET Port S1 Filter AT AT CommandsSnmp Traps, Email Alerts, and Gpio Status Interfacing the SX-560 to the OEM Device SX-560 Evaluation Daughtercard Schematics SX-560 Evaluation Daughtercard Schematics Spics TXD1 Spiclk CTS1 Ground ResetiIicsdc TXD2 Iicsda RXD2 CPIO2, GPIO3Signal Pin Type Description SX-560 Power RequirementsUSB+ USBAntenna Connectors Installing the SX-560Retaining Bracket Optional Antenna Connector Types Parameter DescriptionGeneral Purpose I/O Interface Regulatory Approval RequirementsGpio Interface Pin Drive High/Low DescriptionFactory Default Settings Chapter Advanced ConfigurationFactory Default Settings Parameter Description CTS/RTSParameter Description Settings Default Setting Modifying TCP/IP SettingsChange Password Window Parameter SettingDNS TCP/IP Configuration Settings ParameterCommand Description Configuring SnmpSnmp Commands Snmp Configuration Configuring the General Purpose I/O Gpio LinesShow Gpio DIR Gpio General Commands DescriptionShow Gpio Special SET Gpio Special EN DISShow Gpio Specm DIS Gpio Trigger Commands DescriptionShow Gpio Trigm Gpio Data Commands Gpio Transmit Commands DescriptionTrig # Email String Gpio #1 is Gpio #2 is Trig # Email String Your email text msg here Gpio #2 isShow Gpio Data SET Gpio MON EN DIS Gpio TCP Monitor CommandsShow Gpio MON SET Gpio PortGPIO=00abLF 5 4 3 2 1 Index # Monitor String Port Monitor Alert Commands DescriptionIndex # Xmit String Xmit string Index # Xmit String Trigger string was seenUsing AT Modem Commands Setting up Email Alerts and Snmp TrapsAT Commands Parameter Description Standard AT Commands SupportedAT#Cset nw ssid silex#Csave Parameter Command DescriptionExtended AT Commands Parameter Description Response Codes Numeric Code Description Using ExtendView for Bulk ConfigurationResponse Codes Silex Chapter Product SpecificationsSdio TCP Port ConnectionsTCP Port Connections Port Destination DevicePSK Appendix a Advanced Security ConfigurationEAP Ttls Leap Peap TLS FastWireless Authentication Type Encryption ModeKey Selection WEP Key ValueAuthentication Protocol PasswordAuthentication Certificate Private Key TLS Wireless Security OnlySilex Part Number Advanced Security Configuration Network Commands Appendix B Console CommandsWireless and Network Security Commands TLS Fast WPA-PSK SET NW RTS SET NW PW SET NW IDSET NW Realm SET NW Wpagroup Enable DisableSET NW Inap PAPMSCHAPV2 Port Commands Description Port CommandsSET NW Reset Server Information Commands Description Server Information CommandsCL Port S1 JOB SET Port S1 Size 7Serial number is Serial server Firmware Ver .19 Boot Ver 16Mbit FlashSH Serial Service Commands Description Service CommandsSET Servi service name FRS SET Servi service name FRMSET Servi service name IP ENable DIsable SET Servi service name NAme NewnameSET Snmp Getcomm Snmp CommandsSnmp Commands Description String Commands String CommandsEnter LANGUAGE= POSTSCRIPT\0ATCP/IP Commands TCP/IP CommandsSET IP Http SET IP FTPSET IP LPD Auto Dhcp StaticSET IP Timeout SET IP TELnet ENable DIsableSET IP TCP SET IP TftpAuto SH IPXxxxxxS1A 9100 XxxxxxS1B 3001 Bit# Hex Value Trigger ConditionPower Configuration Power Configuration CommandsSET Power power-level SH PowerHelp Commands Miscellaneous CommandsMiscellaneous Commands SaveAppendix C Engineering Drawings Antenna Cable Drawings and SpecificationsElectrical Performance Parameter Value Antenna Drawings and SpecificationsVswr Electrical Specifications Parameter ValueSilex Part Number Engineering Drawings Tftp -iipaddress put filename access Appendix D Firmware Update ProceduresSilex Part Number Firmware Update Procedures Appendix E Using the Silex Virtual Link USB Software Silex Part Number SVL USB Firmware Appendix F GNU/Linux Open Source and Programming Silex Part Number GNU/Linux Programming Silex Technology America, Inc Appendix G Silex Contact InformationSilex Technology Europe GmbH Silex Technology Beijing, IncSilex Part Number Silex Contact Information Part Number 140-00192-100 Revision C-2 Silex Technology America, Inc