Silex technology manual SX-560 Power Requirements, Signal Pin Type Description, Usb+

Page 47

Signal

Pin

Type

Description

 

 

 

 

CTS1-

28

Input

Serial Port 2 Clear to Send

 

 

 

 

RXD1

34

Input

Serial Port 2 Receive Data

 

 

 

 

TXD2

38

Output

Console Port Transmit Data

 

 

 

 

RXD2

40

Input

Console Port Receive Data

 

 

 

 

USB+

19

Input/Output

USB Data + (SEE NOTE)

 

 

 

 

USB -

21

Input/Output

USB Data – (SEE NOTE)

 

 

 

 

SPI_CS-

25

Output

Serial Peripheral Interface Chip

 

 

 

Select (high-true)

 

 

 

 

SPI_MOSI

31

Output

Serial Peripheral Interface Data

 

 

 

Out

 

 

 

 

SPI_MISO

33

Input

Serial Peripheral Interface Data In

 

 

 

 

SPI_CLK

27

Output

Serial Peripheral Interface Clock

 

 

 

 

RESETI-

1

Output

Power-on Reset (low true)

 

 

 

 

IIC_SDC

37

Input/Output

IIC (I2C) clock

 

 

 

 

IIC_SDA

39

Input/Output

IIC (I2C) data

 

 

 

 

+3.3VDC

6, 18, 23, 30,

Power

Power VCC Input

 

35

 

 

 

 

 

 

GND

5, 17, 24, 29,

Power

Power Ground

 

36

 

 

 

 

 

 

IMPORTANT: If your device does not use the USB port, the USB+ and USB- signals on the OEM interfaced should be terminated with a 15K pull-down resistor to prevent errors on startup.

The SX-560 module uses the 40-pin receptacle with metal fitting and boss made by Hirose (part number DF12-40DS-0.5V81). This receptacle will work with the following mating female headers:

Hirose part number: DF12(x.x)-40DP-0.5V81

Where “x.x” is 3.5, 4.0, or 5.0 (the stacking height of the header); for example, DF12(3.5)-40DP-0.5V81. For additional information, go to the Hirose website at www.hirose-connectors.com.

SX-560 Power Requirements

The SX-560 power consumption is typically 280mA for wireless-to-serial usage, with a peak consumption is 400mA @ 3.3V. In powersave mode (refer to Chapter 4 for more information) with the SX-560 connected wirelessly to an access point, the consumption is 60mA while idling and an average of about 73mA including wakenings to answer the beacon poll.

The above numbers assume that the only active connections are the 802.11 wireless interface and the serial interface (for example, there are no connections to the GPIOs). The power supply that you select must have adequate capacity to handle the peak power plus any loads with an adequate safety margin. Power consumption specifications are subject to change; contact Silex for more information.

Interfacing the SX-560

Silex

Part Number 140-00192-100

Page 41

Image 47
Contents SX-560 Embedded Intelligent Module Trademarks Contents 101 Figures Silex Part Number Contents Emissions Disclaimer Safety PrecautionsAbout This Reference Guide Silex SX-560 top and bottom view IntroductionSilex Part Number Introduction Installing SX-560 Module in Evaluation Daughtercard Chapter Installing the Evaluation DaughtercardSilex Part Number Installing the Evaluation Daughtercard Verify Development Kit Contents SX-560 Module Inserted in Daughtercard Installing the SX-560 ModuleFunction State Status Monitoring Module StatusOEM Interface Status MonitorsOEM Interface Signal Descriptions Pin Type Electrical CharacteristicsDTR DCDRXD TXDCTS DB-9 RS-232 Signal TypeLogical Serial Port 1 Signal Descriptions Pin Input/Output RTSGPIO6 DCD0 GPIO3 TspicsGPIO4 DTR0 GPIO5 DSR026-Pin I/O Header Signal Selectable LED and Gpio Descriptions USB Host Port and Ethernet Port UART0TXD, UART0RTS UART1TXD, UART1RTS UART2TXD LCD InterfaceSilex Part Number Installing the Evaluation Daughtercard Wireless Configuration Settings Chapter Configuring the SX-560Basic Configuration Requirements TCP/IP SettingsConfiguration Methods Initial Wireless SetupConfiguring the SX-560 Silex Part Number Silex Configuring the SX-560 Silex Part Number Silex Using the SX-560 Configuring the SX-560 Silex Part Number Using a Web Browser to Configure the SX-560 Configuring the SX-560 Silex Part Number Using the Internal Command Console to Configure the SX-560 AD-HOC Init Exit SpaceCustomizing the SX-560 User Interface Chapter Using the SX-560 with Your ApplicationLinux Programmability Init Power ConfigurationSET Default Serial Port EmulatorTelnet ipaddress portnumber Raw TCP connectionRFC 2217 Remote Modem Control Support ECable ModeSET Port S1 Constr ++++ Print Server ModeConsole Mode Switching SET Port S1 Filter AT AT CommandsSnmp Traps, Email Alerts, and Gpio Status Interfacing the SX-560 to the OEM Device SX-560 Evaluation Daughtercard Schematics SX-560 Evaluation Daughtercard Schematics CPIO2, GPIO3 ResetiSpics TXD1 Spiclk CTS1 Ground Iicsdc TXD2 Iicsda RXD2USB SX-560 Power RequirementsSignal Pin Type Description USB+Antenna Connectors Installing the SX-560Retaining Bracket Optional Antenna Connector Types Parameter DescriptionDrive High/Low Description Regulatory Approval RequirementsGeneral Purpose I/O Interface Gpio Interface PinCTS/RTS Chapter Advanced ConfigurationFactory Default Settings Factory Default Settings Parameter DescriptionParameter Description Settings Default Setting Modifying TCP/IP SettingsChange Password Window Parameter SettingDNS TCP/IP Configuration Settings ParameterCommand Description Configuring SnmpSnmp Commands Snmp Configuration Configuring the General Purpose I/O Gpio LinesShow Gpio DIR Gpio General Commands DescriptionShow Gpio Special SET Gpio Special EN DISShow Gpio Specm DIS Gpio Trigger Commands DescriptionShow Gpio Trigm Trig # Email String Your email text msg here Gpio #2 is Gpio Transmit Commands DescriptionGpio Data Commands Trig # Email String Gpio #1 is Gpio #2 isShow Gpio Data SET Gpio Port Gpio TCP Monitor CommandsSET Gpio MON EN DIS Show Gpio MONGPIO=00abLF 5 4 3 2 1 Index # Xmit String Trigger string was seen Port Monitor Alert Commands DescriptionIndex # Monitor String Index # Xmit String Xmit stringUsing AT Modem Commands Setting up Email Alerts and Snmp TrapsAT Commands Parameter Description Standard AT Commands SupportedAT#Cset nw ssid silex#Csave Parameter Command DescriptionExtended AT Commands Parameter Description Response Codes Numeric Code Description Using ExtendView for Bulk ConfigurationResponse Codes Silex Chapter Product SpecificationsPort Destination Device TCP Port ConnectionsSdio TCP Port ConnectionsTtls Leap Peap TLS Fast Appendix a Advanced Security ConfigurationPSK EAPWEP Key Value Encryption ModeWireless Authentication Type Key SelectionPrivate Key TLS Wireless Security Only PasswordAuthentication Protocol Authentication CertificateSilex Part Number Advanced Security Configuration Network Commands Appendix B Console CommandsWireless and Network Security Commands TLS Fast WPA-PSK SET NW RTS SET NW PW SET NW IDSET NW Realm SET NW Wpagroup Enable DisableSET NW Inap PAPMSCHAPV2 Port Commands Description Port CommandsSET NW Reset SET Port S1 Size 7 Server Information CommandsServer Information Commands Description CL Port S1 JOBSerial number is Serial server Firmware Ver .19 Boot Ver 16Mbit FlashSH Serial Service Commands Description Service CommandsSET Servi service name NAme Newname SET Servi service name FRMSET Servi service name FRS SET Servi service name IP ENable DIsableSET Snmp Getcomm Snmp CommandsSnmp Commands Description POSTSCRIPT\0A String CommandsString Commands Enter LANGUAGE=TCP/IP Commands TCP/IP CommandsAuto Dhcp Static SET IP FTPSET IP Http SET IP LPDSET IP Tftp SET IP TELnet ENable DIsableSET IP Timeout SET IP TCPBit# Hex Value Trigger Condition SH IPAuto XxxxxxS1A 9100 XxxxxxS1B 3001SH Power Power Configuration CommandsPower Configuration SET Power power-levelSave Miscellaneous CommandsHelp Commands Miscellaneous CommandsAppendix C Engineering Drawings Antenna Cable Drawings and SpecificationsElectrical Performance Parameter Value Antenna Drawings and SpecificationsVswr Electrical Specifications Parameter ValueSilex Part Number Engineering Drawings Tftp -iipaddress put filename access Appendix D Firmware Update ProceduresSilex Part Number Firmware Update Procedures Appendix E Using the Silex Virtual Link USB Software Silex Part Number SVL USB Firmware Appendix F GNU/Linux Open Source and Programming Silex Part Number GNU/Linux Programming Silex Technology Beijing, Inc Appendix G Silex Contact InformationSilex Technology America, Inc Silex Technology Europe GmbHSilex Part Number Silex Contact Information Part Number 140-00192-100 Revision C-2 Silex Technology America, Inc