Silex technology SX-560 manual Power Configuration, Serial Port Emulator, SET Default, Init

Page 38

defined code. For example, by changing the OEM code to XYZ, the default server name SDS000345 would become XYZ000345. To make these changes, enter the following commands using the internal command console:

SET OEM code

where code is the desired 3-character OEM code

SET DEFAULT

[note that this resets the entire SX-560 configuration back to the

 

factory defaults]

SET SERVER DESC description

where description is any string up to 32 characters in length

 

[note that spaces are OK in the description and no quotation

 

marks are necessary]

INIT

[restarts the SX-560 when the user exits the console]

EXIT

[exits the console]

IMPORTANT: This user interface customization must be done before making any other configuration changes, because the SET OEM command requires that the SX-560 be reset to the factory default configuration.

Power Configuration

The SX-560 can be set to go into power save mode by using the console command

SET POWER n

where n is 0 for high (power is always on; this is the default setting) and 2 for low (lowest power consumption). The SHOW POWER command shows the current power configuration.

When power save mode is on, the processor will go to sleep when no activity is detected after a period of time that is determined by a preset algorithm in the SX-560. The processor will wake up in less than a second if there is data waiting for it on the access point, and it will wake up immediately if the SX-560 has a data packet ready to transmit.

Serial Port Emulator

The Serial Port Emulator (SPE) software emulates a standard Windows COM port. That is, it creates a virtual COM port that functions exactly like the Windows COM1 and COM2 serial ports, except that the I/O actually goes out over the Ethernet or WLAN to the SX-560 and to the serial device that is connected to the SX-560. As a result, any application program that uses a standard Windows COM port can also use the Serial Port Emulator. The SPE is therefore especially useful if you have existing programs that use Windows COM ports.

The SPE software is a component on the CD-ROM that is included with the SX-560-6900 Evaluation Daughtercard, or it can be downloaded from the Silex website. To install it, follow the on-screen instructions and then restart your computer when the installation is complete. You can now run the SPE software by clicking Start -> Programs -> silex technology -> Serial Port Emulator -> Serial Port

Emulator.

Page 32

Silex

Part Number 140-00192-100

Using the SX-560

Image 38
Contents SX-560 Embedded Intelligent Module Trademarks Contents 101 Figures Silex Part Number Contents Emissions Disclaimer Safety PrecautionsAbout This Reference Guide Silex Introduction SX-560 top and bottom viewSilex Part Number Introduction Chapter Installing the Evaluation Daughtercard Installing SX-560 Module in Evaluation DaughtercardSilex Part Number Installing the Evaluation Daughtercard Verify Development Kit Contents Installing the SX-560 Module SX-560 Module Inserted in DaughtercardStatus Monitors Monitoring Module StatusOEM Interface Function State StatusElectrical Characteristics OEM Interface Signal Descriptions Pin TypeTXD DCDRXD DTRRTS DB-9 RS-232 Signal TypeLogical Serial Port 1 Signal Descriptions Pin Input/Output CTSGPIO5 DSR0 GPIO3 TspicsGPIO4 DTR0 GPIO6 DCD026-Pin I/O Header Signal Selectable LED and Gpio Descriptions USB Host Port and Ethernet Port LCD Interface UART0TXD, UART0RTS UART1TXD, UART1RTS UART2TXDSilex Part Number Installing the Evaluation Daughtercard TCP/IP Settings Chapter Configuring the SX-560Basic Configuration Requirements Wireless Configuration SettingsInitial Wireless Setup Configuration MethodsConfiguring the SX-560 Silex Part Number Silex Configuring the SX-560 Silex Part Number Silex Using the SX-560 Configuring the SX-560 Silex Part Number Using a Web Browser to Configure the SX-560 Configuring the SX-560 Silex Part Number Using the Internal Command Console to Configure the SX-560 AD-HOC Space Init ExitCustomizing the SX-560 User Interface Chapter Using the SX-560 with Your ApplicationLinux Programmability Serial Port Emulator Power ConfigurationSET Default InitRaw TCP connection Telnet ipaddress portnumberECable Mode RFC 2217 Remote Modem Control SupportSET Port S1 Constr ++++ Print Server ModeConsole Mode Switching SET Port S1 Filter AT AT CommandsSnmp Traps, Email Alerts, and Gpio Status Interfacing the SX-560 to the OEM Device SX-560 Evaluation Daughtercard Schematics SX-560 Evaluation Daughtercard Schematics Iicsdc TXD2 Iicsda RXD2 ResetiSpics TXD1 Spiclk CTS1 Ground CPIO2, GPIO3USB+ SX-560 Power RequirementsSignal Pin Type Description USBInstalling the SX-560 Antenna ConnectorsAntenna Connector Types Parameter Description Retaining Bracket OptionalGpio Interface Pin Regulatory Approval RequirementsGeneral Purpose I/O Interface Drive High/Low DescriptionFactory Default Settings Parameter Description Chapter Advanced ConfigurationFactory Default Settings CTS/RTSModifying TCP/IP Settings Parameter Description Settings Default SettingParameter Setting Change Password WindowTCP/IP Configuration Settings Parameter DNSCommand Description Configuring SnmpSnmp Commands Configuring the General Purpose I/O Gpio Lines Snmp ConfigurationGpio General Commands Description Show Gpio DIRSET Gpio Special EN DIS Show Gpio SpecialShow Gpio Specm Gpio Trigger Commands Description DISShow Gpio Trigm Trig # Email String Gpio #1 is Gpio #2 is Gpio Transmit Commands DescriptionGpio Data Commands Trig # Email String Your email text msg here Gpio #2 isShow Gpio Data Show Gpio MON Gpio TCP Monitor CommandsSET Gpio MON EN DIS SET Gpio PortGPIO=00abLF 5 4 3 2 1 Index # Xmit String Xmit string Port Monitor Alert Commands DescriptionIndex # Monitor String Index # Xmit String Trigger string was seenSetting up Email Alerts and Snmp Traps Using AT Modem CommandsStandard AT Commands Supported AT Commands Parameter DescriptionAT#Cset nw ssid silex#Csave Parameter Command DescriptionExtended AT Commands Parameter Description Response Codes Numeric Code Description Using ExtendView for Bulk ConfigurationResponse Codes Silex Product Specifications ChapterTCP Port Connections TCP Port ConnectionsSdio Port Destination DeviceEAP Appendix a Advanced Security ConfigurationPSK Ttls Leap Peap TLS FastKey Selection Encryption ModeWireless Authentication Type WEP Key ValueAuthentication Certificate PasswordAuthentication Protocol Private Key TLS Wireless Security OnlySilex Part Number Advanced Security Configuration Network Commands Appendix B Console CommandsWireless and Network Security Commands TLS Fast WPA-PSK SET NW RTS SET NW ID SET NW PWSET NW Realm SET NW Wpagroup Enable DisableSET NW Inap PAPMSCHAPV2 Port Commands Description Port CommandsSET NW Reset CL Port S1 JOB Server Information CommandsServer Information Commands Description SET Port S1 Size 7Serial number is Serial server Firmware Ver .19 Boot Ver 16Mbit FlashSH Serial Service Commands Service Commands DescriptionSET Servi service name IP ENable DIsable SET Servi service name FRMSET Servi service name FRS SET Servi service name NAme NewnameSET Snmp Getcomm Snmp CommandsSnmp Commands Description Enter LANGUAGE= String CommandsString Commands POSTSCRIPT\0ATCP/IP Commands TCP/IP CommandsSET IP LPD SET IP FTPSET IP Http Auto Dhcp StaticSET IP TCP SET IP TELnet ENable DIsableSET IP Timeout SET IP TftpXxxxxxS1A 9100 XxxxxxS1B 3001 SH IPAuto Bit# Hex Value Trigger ConditionSET Power power-level Power Configuration CommandsPower Configuration SH PowerMiscellaneous Commands Miscellaneous CommandsHelp Commands SaveAntenna Cable Drawings and Specifications Appendix C Engineering DrawingsAntenna Drawings and Specifications Electrical Performance Parameter ValueElectrical Specifications Parameter Value VswrSilex Part Number Engineering Drawings Appendix D Firmware Update Procedures Tftp -iipaddress put filename accessSilex Part Number Firmware Update Procedures Appendix E Using the Silex Virtual Link USB Software Silex Part Number SVL USB Firmware Appendix F GNU/Linux Open Source and Programming Silex Part Number GNU/Linux Programming Silex Technology Europe GmbH Appendix G Silex Contact InformationSilex Technology America, Inc Silex Technology Beijing, IncSilex Part Number Silex Contact Information Part Number 140-00192-100 Revision C-2 Silex Technology America, Inc