Silex technology SX-560 manual Miscellaneous Commands, Help Commands, Save, Unprotect

Page 96

Miscellaneous Commands

 

 

Table 42 Miscellaneous Commands

 

 

 

 

Command

Description

 

 

SET DEFAULT

Set parameters to factory defaults

 

 

EXIT

This command exits the current configuration console session.

 

 

 

SH

FATal

Shows fatal error log, if fatal errors exist.

 

 

 

CL

FATal

Clears the fatal error log

 

 

INIT

Instructs the server to execute a soft reset when the next exit command is

 

 

executed.

 

 

SET PAssword

Sets the server access (read) password

 

 

SET PROTect

Sets update password to the string given.

 

 

CL PROTect

Sets update password to <null>.

 

 

SAVE

Saves the current configuration to non-volatile memory.

 

 

Without this command, the configuration is not saved unless an EXIT

 

 

command is performed.

 

 

SH TEst

Sends the configuration data via ASCII to the serial port

 

 

UNPROTECT

If an update password has been defined (SET PROTECT), this command

 

 

enters the password to allow configuration items to be modified.

 

 

After entering this command, the server will prompt for the update

 

 

password. If entered properly, the user will then be able to execute SET

 

 

commands to modify the server configuration. This lasts only until the

 

 

console session is terminated with an EXIT command.

 

 

 

Help Commands

For help, simply enter HELP preceding the command. The correct syntax and a brief description of the commands will display. For example, when inquiring for various commands to display specific IP parameters, type HELP SHOW IP, or for commands to change specific wireless/network security parameters, type HELP SET NWRK.

Page 90

Silex

Part Number 140-00192-100

Console Commands

Image 96
Contents SX-560 Embedded Intelligent Module Trademarks Contents 101 Figures Silex Part Number Contents Safety Precautions About This Reference GuideEmissions Disclaimer Silex Introduction SX-560 top and bottom viewSilex Part Number Introduction Chapter Installing the Evaluation Daughtercard Installing SX-560 Module in Evaluation DaughtercardSilex Part Number Installing the Evaluation Daughtercard Verify Development Kit Contents Installing the SX-560 Module SX-560 Module Inserted in DaughtercardMonitoring Module Status OEM InterfaceStatus Monitors Function State StatusElectrical Characteristics OEM Interface Signal Descriptions Pin TypeDCD RXDTXD DTRDB-9 RS-232 Signal Type Logical Serial Port 1 Signal Descriptions Pin Input/OutputRTS CTSGPIO3 Tspics GPIO4 DTR0GPIO5 DSR0 GPIO6 DCD026-Pin I/O Header Signal Selectable LED and Gpio Descriptions USB Host Port and Ethernet Port LCD Interface UART0TXD, UART0RTS UART1TXD, UART1RTS UART2TXDSilex Part Number Installing the Evaluation Daughtercard Chapter Configuring the SX-560 Basic Configuration RequirementsTCP/IP Settings Wireless Configuration SettingsInitial Wireless Setup Configuration MethodsConfiguring the SX-560 Silex Part Number Silex Configuring the SX-560 Silex Part Number Silex Using the SX-560 Configuring the SX-560 Silex Part Number Using a Web Browser to Configure the SX-560 Configuring the SX-560 Silex Part Number Using the Internal Command Console to Configure the SX-560 AD-HOC Space Init ExitChapter Using the SX-560 with Your Application Linux ProgrammabilityCustomizing the SX-560 User Interface Power Configuration SET DefaultSerial Port Emulator InitRaw TCP connection Telnet ipaddress portnumberECable Mode RFC 2217 Remote Modem Control SupportPrint Server Mode Console Mode SwitchingSET Port S1 Constr ++++ AT Commands Snmp Traps, Email Alerts, and Gpio StatusSET Port S1 Filter AT Interfacing the SX-560 to the OEM Device SX-560 Evaluation Daughtercard Schematics SX-560 Evaluation Daughtercard Schematics Reseti Spics TXD1 Spiclk CTS1 GroundIicsdc TXD2 Iicsda RXD2 CPIO2, GPIO3SX-560 Power Requirements Signal Pin Type DescriptionUSB+ USBInstalling the SX-560 Antenna ConnectorsAntenna Connector Types Parameter Description Retaining Bracket OptionalRegulatory Approval Requirements General Purpose I/O InterfaceGpio Interface Pin Drive High/Low DescriptionChapter Advanced Configuration Factory Default SettingsFactory Default Settings Parameter Description CTS/RTSModifying TCP/IP Settings Parameter Description Settings Default SettingParameter Setting Change Password WindowTCP/IP Configuration Settings Parameter DNSConfiguring Snmp Snmp CommandsCommand Description Configuring the General Purpose I/O Gpio Lines Snmp ConfigurationGpio General Commands Description Show Gpio DIRSET Gpio Special EN DIS Show Gpio SpecialShow Gpio Specm Gpio Trigger Commands Description DISShow Gpio Trigm Gpio Transmit Commands Description Gpio Data CommandsTrig # Email String Gpio #1 is Gpio #2 is Trig # Email String Your email text msg here Gpio #2 isShow Gpio Data Gpio TCP Monitor Commands SET Gpio MON EN DISShow Gpio MON SET Gpio PortGPIO=00abLF 5 4 3 2 1 Port Monitor Alert Commands Description Index # Monitor StringIndex # Xmit String Xmit string Index # Xmit String Trigger string was seenSetting up Email Alerts and Snmp Traps Using AT Modem CommandsStandard AT Commands Supported AT Commands Parameter DescriptionParameter Command Description Extended AT Commands Parameter DescriptionAT#Cset nw ssid silex#Csave Using ExtendView for Bulk Configuration Response CodesResponse Codes Numeric Code Description Silex Product Specifications ChapterTCP Port Connections SdioTCP Port Connections Port Destination DeviceAppendix a Advanced Security Configuration PSKEAP Ttls Leap Peap TLS FastEncryption Mode Wireless Authentication TypeKey Selection WEP Key ValuePassword Authentication ProtocolAuthentication Certificate Private Key TLS Wireless Security OnlySilex Part Number Advanced Security Configuration Appendix B Console Commands Wireless and Network Security CommandsNetwork Commands TLS Fast WPA-PSK SET NW RTS SET NW ID SET NW PWSET NW Wpagroup Enable Disable SET NW Inap PAPMSCHAPV2SET NW Realm Port Commands SET NW ResetPort Commands Description Server Information Commands Server Information Commands DescriptionCL Port S1 JOB SET Port S1 Size 7Serial server Firmware Ver .19 Boot Ver 16Mbit Flash SH SerialSerial number is Service Commands Service Commands DescriptionSET Servi service name FRM SET Servi service name FRSSET Servi service name IP ENable DIsable SET Servi service name NAme NewnameSnmp Commands Snmp Commands DescriptionSET Snmp Getcomm String Commands String CommandsEnter LANGUAGE= POSTSCRIPT\0ATCP/IP Commands TCP/IP CommandsSET IP FTP SET IP HttpSET IP LPD Auto Dhcp StaticSET IP TELnet ENable DIsable SET IP TimeoutSET IP TCP SET IP TftpSH IP AutoXxxxxxS1A 9100 XxxxxxS1B 3001 Bit# Hex Value Trigger ConditionPower Configuration Commands Power ConfigurationSET Power power-level SH PowerMiscellaneous Commands Help CommandsMiscellaneous Commands SaveAntenna Cable Drawings and Specifications Appendix C Engineering DrawingsAntenna Drawings and Specifications Electrical Performance Parameter ValueElectrical Specifications Parameter Value VswrSilex Part Number Engineering Drawings Appendix D Firmware Update Procedures Tftp -iipaddress put filename accessSilex Part Number Firmware Update Procedures Appendix E Using the Silex Virtual Link USB Software Silex Part Number SVL USB Firmware Appendix F GNU/Linux Open Source and Programming Silex Part Number GNU/Linux Programming Appendix G Silex Contact Information Silex Technology America, IncSilex Technology Europe GmbH Silex Technology Beijing, IncSilex Part Number Silex Contact Information Part Number 140-00192-100 Revision C-2 Silex Technology America, Inc