Silex technology SX-560 manual Initial Wireless Setup, Configuration Methods

Page 26

Serial Port Settings (must match the settings of the attached serial device):

Baud Rate (Speed)

Parity

Character Size

Flow Control

In addition to the above parameters, the SX-560 allows you to configure numerous other capabilities. These other capabilities provide you with the unparalleled flexibility to use the SX-560 on virtually any 802.11a/b/g network with virtually any RS-232 serial device.

Initial Wireless Setup

NOTE: Skip this section if you are using the Ethernet port on the SX-560-6900 Daughtercard for the configuration process, or if you are using a terminal connected to one of the serial ports on the SX-560.

If you are using a wireless network connection for the first-time configuration of the SX-560, you must set up a temporary ad hoc wireless connection as described in the following steps.

1.Disconnect your PC and the SX-560 from your network, and temporarily change the PC settings as follows:

IP address: 192.0.0.191

Wireless Mode: Ad Hoc (sometimes referred to as Peer-to-Peer)

Channel: 11

SSID (or wireless network name): serserv

Make sure that all network security is disabled.

2.Power on the PC and the SX-560. You can connect to the SX-560 by specifying its default IP address of 192.0.0.192 using the ExtendView utility or a web browser as described in the next sections. After you have connected, you can use ExtendView, the internal web pages, or the internal console to change the SX-560 configuration as follows:

a.Enable AUTO as the boot method or IP address resolution method on the SX-560, or manually change the IP address to the one you will actually be using on your network.

b.Enter the required wireless networking parameters on the SX-560 for operation on your wireless network (for example, SSID, mode, and wireless security).

c.Change the serial port settings to match those of your device.

3.After you complete the entire SX-560 configuration process:

a.Set your PC back to its original network settings, and restart it.

b.Restart the SX-560. The new settings will take effect after the SX-560 has restarted.

Configuration Methods

There are three ways to configure the SX-560:

ExtendView. ExtendView is a simple Graphical User Interface configuration program for Windows. It has the advantage of allowing you to perform bulk configuration of multiple SX-560s simultaneously. If you are using a wired Ethernet connection with the SX-560-6900 evaluation daughtercard, ExtendView also lets you set the IP address and wireless network settings into an unconfigured SX-560 device server (if you are using a wireless network connection for connection, then you must first configure the IP address and wireless network settings using the

Page 20

Silex

Part Number 140-00192-100

Using the SX-560

Image 26
Contents SX-560 Embedded Intelligent Module Trademarks Contents 101 Figures Silex Part Number Contents Emissions Disclaimer Safety PrecautionsAbout This Reference Guide Silex Introduction SX-560 top and bottom viewSilex Part Number Introduction Chapter Installing the Evaluation Daughtercard Installing SX-560 Module in Evaluation DaughtercardSilex Part Number Installing the Evaluation Daughtercard Verify Development Kit Contents Installing the SX-560 Module SX-560 Module Inserted in DaughtercardStatus Monitors Monitoring Module StatusOEM Interface Function State StatusElectrical Characteristics OEM Interface Signal Descriptions Pin TypeTXD DCDRXD DTRRTS DB-9 RS-232 Signal TypeLogical Serial Port 1 Signal Descriptions Pin Input/Output CTSGPIO5 DSR0 GPIO3 TspicsGPIO4 DTR0 GPIO6 DCD026-Pin I/O Header Signal Selectable LED and Gpio Descriptions USB Host Port and Ethernet Port LCD Interface UART0TXD, UART0RTS UART1TXD, UART1RTS UART2TXDSilex Part Number Installing the Evaluation Daughtercard TCP/IP Settings Chapter Configuring the SX-560Basic Configuration Requirements Wireless Configuration SettingsInitial Wireless Setup Configuration MethodsConfiguring the SX-560 Silex Part Number Silex Configuring the SX-560 Silex Part Number Silex Using the SX-560 Configuring the SX-560 Silex Part Number Using a Web Browser to Configure the SX-560 Configuring the SX-560 Silex Part Number Using the Internal Command Console to Configure the SX-560 AD-HOC Space Init ExitCustomizing the SX-560 User Interface Chapter Using the SX-560 with Your ApplicationLinux Programmability Serial Port Emulator Power ConfigurationSET Default InitRaw TCP connection Telnet ipaddress portnumberECable Mode RFC 2217 Remote Modem Control SupportSET Port S1 Constr ++++ Print Server ModeConsole Mode Switching SET Port S1 Filter AT AT CommandsSnmp Traps, Email Alerts, and Gpio Status Interfacing the SX-560 to the OEM Device SX-560 Evaluation Daughtercard Schematics SX-560 Evaluation Daughtercard Schematics Iicsdc TXD2 Iicsda RXD2 ResetiSpics TXD1 Spiclk CTS1 Ground CPIO2, GPIO3USB+ SX-560 Power RequirementsSignal Pin Type Description USBInstalling the SX-560 Antenna ConnectorsAntenna Connector Types Parameter Description Retaining Bracket OptionalGpio Interface Pin Regulatory Approval RequirementsGeneral Purpose I/O Interface Drive High/Low DescriptionFactory Default Settings Parameter Description Chapter Advanced ConfigurationFactory Default Settings CTS/RTSModifying TCP/IP Settings Parameter Description Settings Default SettingParameter Setting Change Password WindowTCP/IP Configuration Settings Parameter DNSCommand Description Configuring SnmpSnmp Commands Configuring the General Purpose I/O Gpio Lines Snmp ConfigurationGpio General Commands Description Show Gpio DIRSET Gpio Special EN DIS Show Gpio SpecialShow Gpio Specm Gpio Trigger Commands Description DISShow Gpio Trigm Trig # Email String Gpio #1 is Gpio #2 is Gpio Transmit Commands DescriptionGpio Data Commands Trig # Email String Your email text msg here Gpio #2 isShow Gpio Data Show Gpio MON Gpio TCP Monitor CommandsSET Gpio MON EN DIS SET Gpio PortGPIO=00abLF 5 4 3 2 1 Index # Xmit String Xmit string Port Monitor Alert Commands DescriptionIndex # Monitor String Index # Xmit String Trigger string was seenSetting up Email Alerts and Snmp Traps Using AT Modem CommandsStandard AT Commands Supported AT Commands Parameter DescriptionAT#Cset nw ssid silex#Csave Parameter Command DescriptionExtended AT Commands Parameter Description Response Codes Numeric Code Description Using ExtendView for Bulk ConfigurationResponse Codes Silex Product Specifications ChapterTCP Port Connections TCP Port ConnectionsSdio Port Destination DeviceEAP Appendix a Advanced Security ConfigurationPSK Ttls Leap Peap TLS FastKey Selection Encryption ModeWireless Authentication Type WEP Key ValueAuthentication Certificate PasswordAuthentication Protocol Private Key TLS Wireless Security OnlySilex Part Number Advanced Security Configuration Network Commands Appendix B Console CommandsWireless and Network Security Commands TLS Fast WPA-PSK SET NW RTS SET NW ID SET NW PWSET NW Realm SET NW Wpagroup Enable DisableSET NW Inap PAPMSCHAPV2 Port Commands Description Port CommandsSET NW Reset CL Port S1 JOB Server Information CommandsServer Information Commands Description SET Port S1 Size 7Serial number is Serial server Firmware Ver .19 Boot Ver 16Mbit FlashSH Serial Service Commands Service Commands DescriptionSET Servi service name IP ENable DIsable SET Servi service name FRMSET Servi service name FRS SET Servi service name NAme NewnameSET Snmp Getcomm Snmp CommandsSnmp Commands Description Enter LANGUAGE= String CommandsString Commands POSTSCRIPT\0ATCP/IP Commands TCP/IP CommandsSET IP LPD SET IP FTPSET IP Http Auto Dhcp StaticSET IP TCP SET IP TELnet ENable DIsableSET IP Timeout SET IP TftpXxxxxxS1A 9100 XxxxxxS1B 3001 SH IPAuto Bit# Hex Value Trigger ConditionSET Power power-level Power Configuration CommandsPower Configuration SH PowerMiscellaneous Commands Miscellaneous CommandsHelp Commands SaveAntenna Cable Drawings and Specifications Appendix C Engineering DrawingsAntenna Drawings and Specifications Electrical Performance Parameter ValueElectrical Specifications Parameter Value VswrSilex Part Number Engineering Drawings Appendix D Firmware Update Procedures Tftp -iipaddress put filename accessSilex Part Number Firmware Update Procedures Appendix E Using the Silex Virtual Link USB Software Silex Part Number SVL USB Firmware Appendix F GNU/Linux Open Source and Programming Silex Part Number GNU/Linux Programming Silex Technology Europe GmbH Appendix G Silex Contact InformationSilex Technology America, Inc Silex Technology Beijing, IncSilex Part Number Silex Contact Information Part Number 140-00192-100 Revision C-2 Silex Technology America, Inc