where ipaddress is the IP address of the SX-560 and portnumber is the SX-560 TCP port number. For example:

telnet 192.168.5.53 9100

In this example, if you have a serial printer or other device capable of displaying ASCII characters connected to the SX-560 Serial Port 1, then every character you type should be printed on that serial device (buffered serial devices may need you to type a control character such as a formfeed (CONTROL- L) before the characters are printed).

RFC 2217 Remote Modem Control Support

RFC 2217 allows you to access your device’s modem control signals over the network. It is especially useful for migrating applications that use modem controls from a direct serial connection to a serial device server network connection. You can utilize RFC 2217 from the Silex Serial Port Emulator software (see below), or by connecting to TCP port 9200 (for Serial Port 1) or port 9201 (for Serial Port 2) from your application program.

ECable Mode

Normally, it is up the computer to initiate a connection to the SX-560. For some applications, it is desirable for the SX-560 to initiate the connection to the computer. The SX-560 supports this capability through its ECable feature.

To set E-Cable mode, use a web browser to access the SX-560 internal web pages (see chapter 3 for instructions on using the internal web pages). After you have logged in, click I/O port on the left side of the screen.

You can now enable ECable mode and set the required parameters.

1.Select the desired port (S1 for Serial Port 1 or S2 for Serial Port 2)

2.Enable ECable mode by clicking the radio button.

3.Enter the address (Destination Address) of the computer or other device that will be communicating with the SX-500)

4.Enter the TCP port number (Destination Port) used by the destination device for communicating with the SX-560 (must be greater 1023).

5.If desired, change the ECable Connection Attempt Time. This specifies the time interval between connection attempts. For example, by default the SX-560 will try once every 30 seconds to make a connection to the destination device; if it fails to make this connection, it will wait 30 seconds before attempting again. Changing this interval will reduce or increase the amount of network traffic.

Page 34

Silex

Part Number 140-00192-100

Using the SX-560

Image 40
Contents SX-560 Embedded Intelligent Module Trademarks Contents 101 Figures Silex Part Number Contents About This Reference Guide Safety PrecautionsEmissions Disclaimer Silex Introduction SX-560 top and bottom viewSilex Part Number Introduction Chapter Installing the Evaluation Daughtercard Installing SX-560 Module in Evaluation DaughtercardSilex Part Number Installing the Evaluation Daughtercard Verify Development Kit Contents Installing the SX-560 Module SX-560 Module Inserted in DaughtercardMonitoring Module Status OEM InterfaceStatus Monitors Function State StatusElectrical Characteristics OEM Interface Signal Descriptions Pin TypeDCD RXDTXD DTRDB-9 RS-232 Signal Type Logical Serial Port 1 Signal Descriptions Pin Input/OutputRTS CTSGPIO3 Tspics GPIO4 DTR0GPIO5 DSR0 GPIO6 DCD026-Pin I/O Header Signal Selectable LED and Gpio Descriptions USB Host Port and Ethernet Port LCD Interface UART0TXD, UART0RTS UART1TXD, UART1RTS UART2TXDSilex Part Number Installing the Evaluation Daughtercard Chapter Configuring the SX-560 Basic Configuration RequirementsTCP/IP Settings Wireless Configuration SettingsInitial Wireless Setup Configuration MethodsConfiguring the SX-560 Silex Part Number Silex Configuring the SX-560 Silex Part Number Silex Using the SX-560 Configuring the SX-560 Silex Part Number Using a Web Browser to Configure the SX-560 Configuring the SX-560 Silex Part Number Using the Internal Command Console to Configure the SX-560 AD-HOC Space Init ExitLinux Programmability Chapter Using the SX-560 with Your ApplicationCustomizing the SX-560 User Interface Power Configuration SET DefaultSerial Port Emulator InitRaw TCP connection Telnet ipaddress portnumberECable Mode RFC 2217 Remote Modem Control SupportConsole Mode Switching Print Server ModeSET Port S1 Constr ++++ Snmp Traps, Email Alerts, and Gpio Status AT CommandsSET Port S1 Filter AT Interfacing the SX-560 to the OEM Device SX-560 Evaluation Daughtercard Schematics SX-560 Evaluation Daughtercard Schematics Reseti Spics TXD1 Spiclk CTS1 GroundIicsdc TXD2 Iicsda RXD2 CPIO2, GPIO3SX-560 Power Requirements Signal Pin Type DescriptionUSB+ USBInstalling the SX-560 Antenna ConnectorsAntenna Connector Types Parameter Description Retaining Bracket OptionalRegulatory Approval Requirements General Purpose I/O InterfaceGpio Interface Pin Drive High/Low DescriptionChapter Advanced Configuration Factory Default SettingsFactory Default Settings Parameter Description CTS/RTSModifying TCP/IP Settings Parameter Description Settings Default SettingParameter Setting Change Password WindowTCP/IP Configuration Settings Parameter DNSSnmp Commands Configuring SnmpCommand Description Configuring the General Purpose I/O Gpio Lines Snmp ConfigurationGpio General Commands Description Show Gpio DIRSET Gpio Special EN DIS Show Gpio SpecialShow Gpio Specm Gpio Trigger Commands Description DISShow Gpio Trigm Gpio Transmit Commands Description Gpio Data CommandsTrig # Email String Gpio #1 is Gpio #2 is Trig # Email String Your email text msg here Gpio #2 isShow Gpio Data Gpio TCP Monitor Commands SET Gpio MON EN DISShow Gpio MON SET Gpio PortGPIO=00abLF 5 4 3 2 1 Port Monitor Alert Commands Description Index # Monitor StringIndex # Xmit String Xmit string Index # Xmit String Trigger string was seenSetting up Email Alerts and Snmp Traps Using AT Modem CommandsStandard AT Commands Supported AT Commands Parameter DescriptionExtended AT Commands Parameter Description Parameter Command DescriptionAT#Cset nw ssid silex#Csave Response Codes Using ExtendView for Bulk ConfigurationResponse Codes Numeric Code Description Silex Product Specifications ChapterTCP Port Connections SdioTCP Port Connections Port Destination DeviceAppendix a Advanced Security Configuration PSKEAP Ttls Leap Peap TLS FastEncryption Mode Wireless Authentication TypeKey Selection WEP Key ValuePassword Authentication ProtocolAuthentication Certificate Private Key TLS Wireless Security OnlySilex Part Number Advanced Security Configuration Wireless and Network Security Commands Appendix B Console CommandsNetwork Commands TLS Fast WPA-PSK SET NW RTS SET NW ID SET NW PWSET NW Inap PAPMSCHAPV2 SET NW Wpagroup Enable DisableSET NW Realm SET NW Reset Port CommandsPort Commands Description Server Information Commands Server Information Commands DescriptionCL Port S1 JOB SET Port S1 Size 7SH Serial Serial server Firmware Ver .19 Boot Ver 16Mbit FlashSerial number is Service Commands Service Commands DescriptionSET Servi service name FRM SET Servi service name FRSSET Servi service name IP ENable DIsable SET Servi service name NAme NewnameSnmp Commands Description Snmp CommandsSET Snmp Getcomm String Commands String CommandsEnter LANGUAGE= POSTSCRIPT\0ATCP/IP Commands TCP/IP CommandsSET IP FTP SET IP HttpSET IP LPD Auto Dhcp StaticSET IP TELnet ENable DIsable SET IP TimeoutSET IP TCP SET IP TftpSH IP AutoXxxxxxS1A 9100 XxxxxxS1B 3001 Bit# Hex Value Trigger ConditionPower Configuration Commands Power ConfigurationSET Power power-level SH PowerMiscellaneous Commands Help CommandsMiscellaneous Commands SaveAntenna Cable Drawings and Specifications Appendix C Engineering DrawingsAntenna Drawings and Specifications Electrical Performance Parameter ValueElectrical Specifications Parameter Value VswrSilex Part Number Engineering Drawings Appendix D Firmware Update Procedures Tftp -iipaddress put filename accessSilex Part Number Firmware Update Procedures Appendix E Using the Silex Virtual Link USB Software Silex Part Number SVL USB Firmware Appendix F GNU/Linux Open Source and Programming Silex Part Number GNU/Linux Programming Appendix G Silex Contact Information Silex Technology America, IncSilex Technology Europe GmbH Silex Technology Beijing, IncSilex Part Number Silex Contact Information Part Number 140-00192-100 Revision C-2 Silex Technology America, Inc