Silex technology manual Installing the SX-560 Module, SX-560 Module Inserted in Daughtercard

Page 14

Installing the SX-560 Module

To install the SX-560 module in the SX-560-6900 Evaluation Daughtercard:

1.Using the 40-pin OEM interface header (JP2), plug the SX-560 Module in the SX-560-6900 Evaluation Daughtercard and secure with screws, nuts and spacers (you may optionally use the metal retaining bracket to secure the radio card and to reduce electromagnetic interference; refer to Chapter 5 for information on using this bracket). Important: The spacers MUST be installed to avoid potential damage to the boards.

Figure 3 SX-560 Module Inserted in Daughtercard

2.The Evaluation Daughtercard includes both on-board bead antennas and external antennas. Use the included U.FL to U.FL cables with the bead antennas or the U.FL to RP-SMA cables with the external antennas. Plug the main antenna cable into the Main Antenna Connector on the card (see Figure 3). Plug the auxiliary antenna cable into the Auxiliary Antenna Connector (the auxiliary antenna improves radio reception, but is not required for operation).

3.If you are using the on-board bead antennas, connect the other end of the antenna cable(s) into either of the built-in bead antenna connectors (J7 and J8) as shown in figure 3. If you are using the external antennas, connect the RP-SMA end of the antenna cable(s) to the external antenna(s).

4.Connect one serial null-modem cable from the Serial Port 3 DB-9 connector (J5) on the Evaluation Daughtercard to a serial port on a personal computer or laptop (the computer’s serial port must be set to 115.2Kbps, no parity, no flow control, and 8-bit character size). The PC or laptop acts as a console port for command line configuration and monitoring.

5.If you want to use an Ethernet LAN connection for the initial configuration of the SX-560 (recommended), plug a category 5 Ethernet cable into the RJ-45 jack. The Ethernet interface has Auto-MDIX that automatically detects and configures itself for either a straight-thru or crossover Ethernet cable.

Page 8

silex

Part Number 140-00192-100

Installing the Evaluation Daughtercard

Image 14
Contents SX-560 Embedded Intelligent Module Trademarks Contents 101 Figures Silex Part Number Contents Emissions Disclaimer Safety PrecautionsAbout This Reference Guide Silex Introduction SX-560 top and bottom viewSilex Part Number Introduction Chapter Installing the Evaluation Daughtercard Installing SX-560 Module in Evaluation DaughtercardSilex Part Number Installing the Evaluation Daughtercard Verify Development Kit Contents Installing the SX-560 Module SX-560 Module Inserted in DaughtercardStatus Monitors Monitoring Module StatusOEM Interface Function State StatusElectrical Characteristics OEM Interface Signal Descriptions Pin TypeTXD DCDRXD DTRRTS DB-9 RS-232 Signal TypeLogical Serial Port 1 Signal Descriptions Pin Input/Output CTSGPIO5 DSR0 GPIO3 TspicsGPIO4 DTR0 GPIO6 DCD026-Pin I/O Header Signal Selectable LED and Gpio Descriptions USB Host Port and Ethernet Port LCD Interface UART0TXD, UART0RTS UART1TXD, UART1RTS UART2TXDSilex Part Number Installing the Evaluation Daughtercard TCP/IP Settings Chapter Configuring the SX-560Basic Configuration Requirements Wireless Configuration SettingsInitial Wireless Setup Configuration MethodsConfiguring the SX-560 Silex Part Number Silex Configuring the SX-560 Silex Part Number Silex Using the SX-560 Configuring the SX-560 Silex Part Number Using a Web Browser to Configure the SX-560 Configuring the SX-560 Silex Part Number Using the Internal Command Console to Configure the SX-560 AD-HOC Space Init ExitCustomizing the SX-560 User Interface Chapter Using the SX-560 with Your ApplicationLinux Programmability Serial Port Emulator Power ConfigurationSET Default InitRaw TCP connection Telnet ipaddress portnumberECable Mode RFC 2217 Remote Modem Control SupportSET Port S1 Constr ++++ Print Server ModeConsole Mode Switching SET Port S1 Filter AT AT CommandsSnmp Traps, Email Alerts, and Gpio Status Interfacing the SX-560 to the OEM Device SX-560 Evaluation Daughtercard Schematics SX-560 Evaluation Daughtercard Schematics Iicsdc TXD2 Iicsda RXD2 ResetiSpics TXD1 Spiclk CTS1 Ground CPIO2, GPIO3USB+ SX-560 Power RequirementsSignal Pin Type Description USBInstalling the SX-560 Antenna ConnectorsAntenna Connector Types Parameter Description Retaining Bracket OptionalGpio Interface Pin Regulatory Approval RequirementsGeneral Purpose I/O Interface Drive High/Low DescriptionFactory Default Settings Parameter Description Chapter Advanced ConfigurationFactory Default Settings CTS/RTSModifying TCP/IP Settings Parameter Description Settings Default SettingParameter Setting Change Password WindowTCP/IP Configuration Settings Parameter DNSCommand Description Configuring SnmpSnmp Commands Configuring the General Purpose I/O Gpio Lines Snmp ConfigurationGpio General Commands Description Show Gpio DIRSET Gpio Special EN DIS Show Gpio SpecialShow Gpio Specm Gpio Trigger Commands Description DISShow Gpio Trigm Trig # Email String Gpio #1 is Gpio #2 is Gpio Transmit Commands DescriptionGpio Data Commands Trig # Email String Your email text msg here Gpio #2 isShow Gpio Data Show Gpio MON Gpio TCP Monitor CommandsSET Gpio MON EN DIS SET Gpio PortGPIO=00abLF 5 4 3 2 1 Index # Xmit String Xmit string Port Monitor Alert Commands DescriptionIndex # Monitor String Index # Xmit String Trigger string was seenSetting up Email Alerts and Snmp Traps Using AT Modem CommandsStandard AT Commands Supported AT Commands Parameter DescriptionAT#Cset nw ssid silex#Csave Parameter Command DescriptionExtended AT Commands Parameter Description Response Codes Numeric Code Description Using ExtendView for Bulk ConfigurationResponse Codes Silex Product Specifications ChapterTCP Port Connections TCP Port ConnectionsSdio Port Destination DeviceEAP Appendix a Advanced Security ConfigurationPSK Ttls Leap Peap TLS FastKey Selection Encryption ModeWireless Authentication Type WEP Key ValueAuthentication Certificate PasswordAuthentication Protocol Private Key TLS Wireless Security OnlySilex Part Number Advanced Security Configuration Network Commands Appendix B Console CommandsWireless and Network Security Commands TLS Fast WPA-PSK SET NW RTS SET NW ID SET NW PWSET NW Realm SET NW Wpagroup Enable DisableSET NW Inap PAPMSCHAPV2 Port Commands Description Port CommandsSET NW Reset CL Port S1 JOB Server Information CommandsServer Information Commands Description SET Port S1 Size 7Serial number is Serial server Firmware Ver .19 Boot Ver 16Mbit FlashSH Serial Service Commands Service Commands DescriptionSET Servi service name IP ENable DIsable SET Servi service name FRMSET Servi service name FRS SET Servi service name NAme NewnameSET Snmp Getcomm Snmp CommandsSnmp Commands Description Enter LANGUAGE= String CommandsString Commands POSTSCRIPT\0ATCP/IP Commands TCP/IP CommandsSET IP LPD SET IP FTPSET IP Http Auto Dhcp StaticSET IP TCP SET IP TELnet ENable DIsableSET IP Timeout SET IP TftpXxxxxxS1A 9100 XxxxxxS1B 3001 SH IPAuto Bit# Hex Value Trigger ConditionSET Power power-level Power Configuration CommandsPower Configuration SH PowerMiscellaneous Commands Miscellaneous CommandsHelp Commands SaveAntenna Cable Drawings and Specifications Appendix C Engineering DrawingsAntenna Drawings and Specifications Electrical Performance Parameter ValueElectrical Specifications Parameter Value VswrSilex Part Number Engineering Drawings Appendix D Firmware Update Procedures Tftp -iipaddress put filename accessSilex Part Number Firmware Update Procedures Appendix E Using the Silex Virtual Link USB Software Silex Part Number SVL USB Firmware Appendix F GNU/Linux Open Source and Programming Silex Part Number GNU/Linux Programming Silex Technology Europe GmbH Appendix G Silex Contact InformationSilex Technology America, Inc Silex Technology Beijing, IncSilex Part Number Silex Contact Information Part Number 140-00192-100 Revision C-2 Silex Technology America, Inc