QF!Pqujpot
(cont.)
Backfeed Cntrl
*20 ms after print
40 ms after print
60 ms after print
80 ms after print
99 ms after print no backfeed before print
Ribbon Low
*Active Low
Active High
Sjccpo!Mpx!Ejb
/
*20
Value range:
Qsjoufs!Npefm
*Left Hand
*Right Hand
Dpvoufst
Absolute Values
Ebuf0Ujnf
Mbcfm!Pqujpot
Heat Setting
*10
Value range:
Controls the timing associated with the backfeeding of a presented label.
20 millisecond delay before printing the next label.
40 millisecond delay before printing the next label.
60 millisecond delay before printing the next label.
80 millisecond delay before printing the next label.
99 millisecond delay before printing the next label. Disables all backfeed motion.
Backfeeds without delay, upon next print cycle.
Sets the output polarity of the applicator port pin #2 ribbon low signal.
Signal goes low for ribbon low condition. Signal goes high for ribbon low condition.
Allows user to select how much ribbon will remain when a Low Ribbon message is displayed.
The value selected is the remaining diameter in tenths of an inch.
Instructs the printer of the mechanism’s configuration for printhead zero dot orientation.
Right side label output. Left side label output.
Read only check of the printer’s absolute values. Given in inches; not resettable.
Allows the current date and time fields to be changed.
Allows access to six label parameters.
Allows the selection of different heat settings. Changes the "on time" of the printhead dots.
The higher value, the darker the print.
PE Series Operator’s Manual | 33 |