| Error Messages |
|
| Table 4. Message List |
|
|
|
|
|
|
Message | Explanation | Solution |
|
|
|
|
|
|
|
|
|
Bar code quiet | Data validation error: the | 1. Fix the application. |
|
zone too small | blank zone(s) left or right of | 2. Disable Quiet Zone in |
|
| the bar code is not big |
| |
| the VALIDATOR menu. |
| |
| enough to meet the minimum |
| |
|
|
| |
| requirement. |
|
|
| Typically, this occurs in forms |
|
|
| where bar codes are placed |
|
|
| too close to other elements, |
|
|
| the bar code is too close to an |
|
|
| edge of the media, or the |
|
|
| media’s position is shifting. |
|
|
| The minimum quiet zone on |
|
|
| each end of the bar code |
|
|
| should be ten times the |
|
|
| minimum element width or 1/ |
|
|
| 4 inch, whichever is greater. |
|
|
| In addition, between bar |
|
|
| codes, the validator requires |
|
|
| a minimum distance of 20 |
|
|
| times the minimum element |
|
|
| width or 1/2 inch, whichever is |
|
|
| greater. |
|
|
|
|
|
|
Calibration | The validator has detected | Press PAUSE to clear the |
|
warning | that it needs calibration. This | message. Calibrate the |
|
| message is a reminder and | validator. See “Calibration” |
|
| does not halt printing. | on page 34. |
|
|
|
|
|
Checksum Failure | The bar code data fails the | Verify that the checksum |
|
| checksum check or is missing | digit exists in the bar code |
|
| the checksum digit. | and that it is the correct |
|
|
| value. |
|
|
|
|
|
65