Trane CCUN 205-211, CGAN 209-214, CH530, CGWN 205-211 manual Main Screens, Main Reports Settings

Page 8

DynaView Interface

Main Screens

The Main screen shall be the default screen. After an idle time of

30 minutes the CH530 shall display the Main screen with the first data fields. The remaining items (listed in the following table) will be viewed by selecting the up/down arrow icons.

Figure 3 - Main screen

Main Reports Settings

Chiller Mode:

 

Running

Circuit 1 Mode:

 

Running - Limit

Circuit 2 Mode:

 

Auto

Evap Ent / Lvg Water Temp:

12 / 7

C

Cond Ent / Lvg Water Temp:

30 / 35

C

Active Chilled Water Setpoint:

7

C

Auto

Stop

 

 

8

CG-SVU02B-E4

Image 8
Contents User Guide Safety recommendations General informationForeword ReceptionTraining WarrantyMaintenance contract Contents Overview Controls InterfaceDynaView Interface Display ScreensKeypad/Display Lockout Feature KeypadMain Reports Settings Main ScreensAuto Stop Chiller Level Mode Top Level Mode Description MP Resetting MP Resetting Sub Modes DescriptionChiller Level Mode Top Level Mode Description Stopped Stopped Sub Modes DescriptionChiller Level Mode Top Level Mode Description Run Inhibit Chiller Level Mode Top Level Mode Description AutoRun Inhibit Sub Modes Description Auto Sub Modes DescriptionChiller Level Mode Top Level Mode Description Running Chiller Level Mode Top Level Mode Description Running LimitWaiting to Start Sub Modes Description Running Sub Modes DescriptionChiller Level Mode Top Level Mode Description Shutting Down Chiller Level Mode Top Level Mode Description MiscShutting Down Sub Modes Description Misc. Sub Modes DescriptionCircuit Level Operating Modes Circuit Level Mode Top Level Mode Description Running Limit Circuit Level Mode Top Level Mode Description Shutting DownCircuit Level Mode Top Level Mode Description Misc Preparing Shutdown Sub Modes DescriptionReports Screen Circuit Ashrae Log Historic DiagnosticsAshrae Chiller Log Settings Screen Description Units Resolution, Default ChillerFeature Settings System Manual Control SettingsCircuit Manual Control Settings Display SettingsDiagnostics Screen Chiller Mode StoppedTechView Interface CD-ROMSoftware Download TechView Interface Diagnostics Active Diagnostic Name Effects Severity Modes Criteria Reset Inactive Level MP Reset Has OccurredCompressor Fault Low Pressure CutoutSuction Temperature Sensor TemperatureEvaporator Entering Water Temp Sensor Evaporator Leaving WaterError High Evaporator WaterHigh Pressure Cutout Emergency StopFault Detected Pump Fault DetectedPump 1 or Fan Fault Evaporator WaterDiagnostic Name Effects Severity Active Criteria Reset Modes Level InactiveDiagnostics Special Main Processor Boot Messages and Diagnostics DynaView Display Message Description TroubleshootingDiagnostics Event/state Description Programmable Relays Alarms and StatusDefault setting Event/Status CG-SVU02B-E4 CG-SVU02B-E4