Trane CCUN 205-211, CGAN 209-214, CH530, CGWN 205-211 manual Contents

Page 4

Contents

General Information

2

Overview

5

DynaView Interface

6

 

 

Display Screens

 

6

TechView Interface

19

 

 

Software Download

 

20

Diagnostics

22

4

CG-SVU02B-E4

Image 4
Contents User Guide Safety recommendations General informationForeword ReceptionMaintenance contract WarrantyTraining Contents Overview Controls InterfaceDynaView Interface Display ScreensKeypad/Display Lockout Feature KeypadMain Reports Settings Main ScreensAuto Stop Chiller Level Mode Top Level Mode Description MP Resetting MP Resetting Sub Modes DescriptionChiller Level Mode Top Level Mode Description Stopped Stopped Sub Modes DescriptionChiller Level Mode Top Level Mode Description Run Inhibit Chiller Level Mode Top Level Mode Description AutoRun Inhibit Sub Modes Description Auto Sub Modes DescriptionChiller Level Mode Top Level Mode Description Running Chiller Level Mode Top Level Mode Description Running LimitWaiting to Start Sub Modes Description Running Sub Modes DescriptionChiller Level Mode Top Level Mode Description Shutting Down Chiller Level Mode Top Level Mode Description MiscShutting Down Sub Modes Description Misc. Sub Modes DescriptionCircuit Level Operating Modes Circuit Level Mode Top Level Mode Description Running Limit Circuit Level Mode Top Level Mode Description Shutting DownCircuit Level Mode Top Level Mode Description Misc Preparing Shutdown Sub Modes DescriptionReports Screen Ashrae Chiller Log Historic DiagnosticsCircuit Ashrae Log Settings Screen Description Units Resolution, Default ChillerFeature Settings System Manual Control SettingsCircuit Manual Control Settings Display SettingsDiagnostics Screen Chiller Mode StoppedTechView Interface CD-ROMSoftware Download TechView Interface Diagnostics Active Diagnostic Name Effects Severity Modes Criteria Reset Inactive Level MP Reset Has OccurredCompressor Fault Low Pressure CutoutSuction Temperature Sensor TemperatureEvaporator Entering Water Temp Sensor Evaporator Leaving WaterError High Evaporator WaterHigh Pressure Cutout Emergency StopFault Detected Pump Fault DetectedPump 1 or Fan Fault Evaporator WaterDiagnostic Name Effects Severity Active Criteria Reset Modes Level InactiveDiagnostics Special Main Processor Boot Messages and Diagnostics DynaView Display Message Description TroubleshootingDiagnostics Default setting Event/Status Programmable Relays Alarms and StatusEvent/state Description CG-SVU02B-E4 CG-SVU02B-E4