6.Select the product family. A table with the download link will appear for that product family.

7.Download the main processor software onto your PC in the CH530 folder (please note that this does not install the main processor, it only downloads the installation utility).

To do this, click on the latest version of the main processor.

Select "Save this program to disk" while downloading the files (do not select "Run this program from its current location").

8.Remember where you downloaded the files (the "CH530" folder). You will need to locate them to finish the installation process.

9.To complete the installation process, locate the installation utilities you downloaded into the CH530 folder. If necessary, use your PC's file manager to locate the downloaded files.

10.Install the applications in the following order by double- clicking on the install program and following the installation prompts:

Java Runtime Environment (JRE_VXXX.exe)

Note: During the Java Runtime Environment installation, you may be prompted to "select the default Java Runtime for the system browsers...". Do not select any system browsers at this step. There should be no default browsers selected for proper operation.

TechView (6200-0347-VXXX.exe)

The main processor

(6200-XXXX-XX-XX.exe).

-The main processor program will self extract to the proper folder within the TechView program directory, provided the TechView program is properly installed on the C:\ drive.

11.Connect your PC to the CH530 main processor using a standard 9-pin male/9-pin female RS-232 cable.

12.Run the TechView software by selecting the TechView icon placed on your desktop during the installation process. The "Help...About" menu can be viewed to confirm proper installation of latest versions.

CG-SVU02B-E4

23

Image 23
Contents User Guide Reception Safety recommendationsGeneral information ForewordTraining WarrantyMaintenance contract Contents Controls Interface OverviewDisplay Screens DynaView InterfaceKeypad Keypad/Display Lockout FeatureMain Screens Main Reports SettingsAuto Stop Stopped Sub Modes Description Chiller Level Mode Top Level Mode Description MP ResettingMP Resetting Sub Modes Description Chiller Level Mode Top Level Mode Description StoppedAuto Sub Modes Description Chiller Level Mode Top Level Mode Description Run InhibitChiller Level Mode Top Level Mode Description Auto Run Inhibit Sub Modes DescriptionRunning Sub Modes Description Chiller Level Mode Top Level Mode Description RunningChiller Level Mode Top Level Mode Description Running Limit Waiting to Start Sub Modes DescriptionMisc. Sub Modes Description Chiller Level Mode Top Level Mode Description Shutting DownChiller Level Mode Top Level Mode Description Misc Shutting Down Sub Modes DescriptionCircuit Level Operating Modes Preparing Shutdown Sub Modes Description Circuit Level Mode Top Level Mode Description Running LimitCircuit Level Mode Top Level Mode Description Shutting Down Circuit Level Mode Top Level Mode Description MiscReports Screen Circuit Ashrae Log Historic DiagnosticsAshrae Chiller Log Description Units Resolution, Default Chiller Settings ScreenDisplay Settings Feature SettingsSystem Manual Control Settings Circuit Manual Control SettingsChiller Mode Stopped Diagnostics ScreenCD-ROM TechView InterfaceSoftware Download TechView Interface Diagnostics Low Pressure Cutout Active Diagnostic Name Effects SeverityModes Criteria Reset Inactive Level MP Reset Has Occurred Compressor FaultTemp Sensor Evaporator Leaving Water Suction Temperature SensorTemperature Evaporator Entering WaterEmergency Stop ErrorHigh Evaporator Water High Pressure CutoutEvaporator Water Fault DetectedPump Fault Detected Pump 1 or Fan FaultActive Criteria Reset Modes Level Inactive Diagnostic Name Effects SeverityDiagnostics Special DynaView Display Message Description Troubleshooting Main Processor Boot Messages and DiagnosticsDiagnostics Event/state Description Programmable Relays Alarms and StatusDefault setting Event/Status CG-SVU02B-E4 CG-SVU02B-E4