3.4.3Loading Media in
1.Refer to section 3.4.1 to load the media.
2.Feed the paper, printing side facing up, through the paper guide and pass over the platen.
3.Move the media guides to fit the label width by turning the guide adjuster knob.
4.Use “Diagnostic Tool” to set the media sensor type and calibrate the selected sensor. (Start the “Diagnostic tool” Select the “Printer Configuration” tab Click the
“Calibrate Sensor” button) Please refer to the diagnostic utility quick start guide for more information.
5.Open the
6. Lead the media through the backing paper opening, beneath the
Backing paper opening
7. Push the peel-off panel back to the printer
15