4-10 CHAPTER 4: LOADING NETWORK DRIVERS

2Select Configuration/Diagnostic/Troubleshooting, and press [Enter].

3Select Configuration and Diagnostic Program and press [Enter].

4The next screen lists the installed adapters. Write down their slot numbers.

5Exit the program.

If you are using an ODI driver with multiple adapters already installed and you have not updated the NET.CFG file, specify which adapter you want the driver to recognize by adding the slot number to the NET.CFG file using the SLOT XXXX parameter, where XXXX is the slot number.

One Adapter in a Server

If you are running NetWare and have installed a single adapter in an EISA computer that is functioning as a server, follow the instructions in this section to load the NetWare 4.x server driver.

The 3C59X EtherDisk diskette contains a NetWare 4.x server driver (3C59X.LAN) and the NetWare Loadable Modules (NLMs) that enable the NetWare 4.x driver to be used with NetWare 3.11, 3.12, or 4.0x software. These files are found in the subdirectories in the \NETWARE subdirectory.

Driver Installation with NetWare

To load the 4.x server driver, follow these steps:

1Copy the contents of the appropriate \NETWARE\SERVER subdirectory to the boot partition of the server’s hard disk.

The 3C59X EtherDisk diskette contains the NetWare 4.x server driver and the NetWare Loadable Modules (NLMs) that enable the NetWare 4.x driver to be used with NetWare 3.11, 3.12, 4.0x, or 4.1 software.

Image 41
Contents Adapters 3Com Corporation 5400 Bayfront Plaza Santa Clara, California Lifetime Warranty France, Israel Contents Performing Troubleshooting and Diagnostic Tests Cispr B Compliance Figures Tables Introduction How to Use This GuideAbout this Guide Print autolink.log ConventionsIntroduction Features Optional Adapter Installing the EisaInserting the Adapter Installing the Boot PromInspecting the Adapter PCI and Eisa Bus Slots in an Eisa Computer List of devices appears, arranged by type Confirming Adapter InstallationName of the installed 3Com adapter appears, as shown below Connecting to Thin Ethernet Cable Connecting to the NetworkConnecting to the On-board Transceiver Connecting to an External Transceiver Slide Latch Auto Select Media Type Adapter Configuration Overview ConfiguringConfiguring the Adapter Using a NOS Other Than WindowsUsing Windows Software Option Settings Full Duplex Media TypeNetwork Driver Optimization Type at the prompt Changing the SettingsI N N U Press Tab to highlight OK. Press Enter Continue this procedure with any of the other optionsSelect Adapter Installed Adapters Drivers Loading NetworkLocating the Network Drivers Accessing DOSOne Adapter in a Client Loading NetWare ODI DriversAutoLink Requirements Alternatively, at the prompt, type At the prompt, typeAutoLink Information Screen To print the file, type Multiple Adapters in a ClientWhen the program has finished a Save the configuration Main menu appears Reboot the computer Finding the Adapter’s Slot NumberRepeat a for the second adapter One Adapter in a Server For NetWare 3.12, 4.0x, or Multiple Adapters in a ServerFinding the Adapter’s Port Address for Multiple Adapters Bind IPX to X NET=XXXX Bind IPX to Y NET=XXXX Click OK This imports the driver from the EtherDisk diskette Loading Windows 95 DriversNdis Drivers Loading Drivers in Non-NetWare EnvironmentsAdditional Drivers Using Transcend PC Link SmartAgent SoftwareDesktop Management Interface Troubleshooting Overview Performing Troubleshooting Diagnostic TestsTroubleshooting with the Diagnostic Tests Starting the Diagnostic Program Starting the Diagnostic ProgramRunning the Group 1 Tests Assembling a Loopback Plug Running the Group 2 TestRunning the Group 3 Test Setting Up an Echo ServerStart the diagnostic program on the echo server Getting Help If a Test Fails If this test fails, try another loopback plug To change the test parameters, follow these steps Changing the Test SetupLink Beat LED Miscellaneous ChecksAdapter Specifications SpecificationsAUI Connector Pin Assignments RJ-45 Connector Pin AssignmentsRG59 B/U 50 ohm Cable RequirementsFor unshielded twisted-pair UTP connections 100 ohm 3Com Bulletin Board Service On-line Technical ServicesAccess by Modem Technical SupportWorld Wide Web Site 3ComFacts Automated Fax ServiceThreeComForum on CompuServe To use ThreeComForum Log on to CompuServeLocal numbers are available within the following countries Support from Your Network SupplierTo obtain an RMA number, call or fax Returning Products for RepairAUI cable GlossaryBackplane BackboneBus Echo serverEthernet EMM386Twisted-pair Numerics SymbolsIndex Eisa fiber-optic Windows 3.X 4-3 Windows 95 1-2, 3-3 Limited Warranty Santa Clara, CA 95052-8145 408 Interference Handbook CE Notice