American Power Conversion DC Series user manual System Configuration, DCM00K02W481, DCM00K02W482

Page 23

3 System Configuration

The MX06 40A shelf is designed to meet a wide range of customer requirements/applications. A number of versions and options are available including various distribution types, alternative input supply configurations, 19 and 23 inch mounting versions, temperature probes etc.

Contact APC for details.

Alternatively the following pre configured systems are available:

DCM00K02W481

Rear access 40A system with 4 x 10A circuit breaker output distribution, includes alarm card with LED display option, 19” mounting brackets, single phase – single feed input, 3 rectifier blanking panels and a non temperature compensated output voltage of 54.5Vdc. Probe for temperature compensation supplied.

DCM00K02W482

Front access 40A system with 4 x 10A circuit breaker output distribution, includes front access alarm card with LED display option, 19” mounting brackets, single phase – single feed input, 3 rectifier blanking panels and a non temperature compensated output voltage of 54.5Vdc. Probe for temperature compensation supplied.

DCM00K02W483

Rear access 40A system with 10 way GMT fuse output distribution, includes a selection of GMT output fuses, alarm card with LED display option, 19” mounting brackets, single phase – single feed input, 3 rectifier blanking panels and a non temperature compensated output voltage of 54.5Vdc. Probe for temperature compensation supplied.

DCM00K02W484

Front access 40A system with 10 way GMT fuse output distribution, includes a selection of GMT output fuses, front access alarm card with LED display option, 19” mounting brackets, single phase – single feed input, 3 rectifier blanking panels and a non temperature compensated output voltage of 54.5Vdc. Probe for temperature compensation supplied.

User Manual 990-9178A

Page 23 of 44

18th FEB 02

DC MX06 40A Shelf

Image 23
Contents DC Series MX06 40A Shelf DC MX06 40A Shelf Contents Issue Record Introduction Safety PrecautionsGeneral Information CEC Code C22.1-98 Canada Types of HazardsConcealed Damage Inspection upon Receipt of GoodsGeneral Visible External DamageAPC Worldwide Customer Support Warranty Limitations Warranty InformationLimited Warranty Rectifier Parameter per rectifier 1TWF0500H54 SpecificationProduct Overview and Technical Description Display + LED’s SK11 Alarm Card LayoutController SK10Access AlarmsAvailable Alarms Front Access Alarms Knockout Panels Rear Access AlarmsAlarm Description Major alarm Minor alarm Selection Major and Minor AlarmsOutput Voltage Programming Customer InputsCurrent Limit Programming Enable Function Input Description Location Battery Test Function Input Description LocationSystem Controller Temperature Compensation Input Description Socket PinMechanical DimensionsWeight Mounting Options Positive Earth Configured SchematicNegative Earth Configured DCM00K02W483 System ConfigurationDCM00K02W481 DCM00K02W482AC Primary Supply Installation ProcedureSingle Phase Rear Access ConnectionTerminal Block Cable Gland Front Access ConnectionSingle Phase, AB Feed Front Access Connection 3 3 Phase Star Supply Front access connection 4 3 Phase Delta Supply Front access connection DC Distribution 1 10 GMT Fuses Rear Access2 10 GMT Fuses Front Access Ambient Temperature3 4 Circuit Breakers Rear Access 4 4 Circuit Breakers Front Access 6 4 Cartridge Fuses Front Access 5 4 Cartridge Fuses Rear AccessInput cables Routing Of CablesOutput Cables LVD Function External Battery InstallationBattery Back-up function System Output Earthing Battery Connection DiagramGeneral Powering up the MX06 40A ShelfCommissioning the System Method Manual Handling ProcedurePreparation Fault Symptoms Fault Finding / SymptomsController replacement Service, Accessories & SparesRectifier replacement