American Power Conversion DC Series user manual 5 4 Cartridge Fuses Rear Access

Page 36

4.2.54 Cartridge Fuses Rear Access

No. of Outputs :

4

Output Rating :

4 O/P’s up to 20A max

 

2 O/P’s up to 25A max

Fuses :

1 O/P up to 25A max

Bussmann NITD range

Trip Alarm :

YES

To connect the cables to the system follow the same procedure as for the “4 Circuit Breaker Rear Access” distribution module (section 4.2.3).

4.2.64 Cartridge Fuses Front Access

The ratings are the same as for the rear access version above.

To connect the cables to the system follow the same procedure as for the 4 Circuit Breaker Front Access distribution module. (see section 4.2.3)

DISTRIBUTION

INPUT

CONTROLLER

1

2

3

4

1

2

3

4

1 2

FUSES

3 4

Note/ to gain access to the fuses remove the distribution front panel (front and rear access versions)

User Manual 990-9178A

Page 36 of 44

18th FEB 02

DC MX06 40A Shelf

Image 36
Contents DC Series MX06 40A Shelf DC MX06 40A Shelf Contents Issue Record Safety Precautions General InformationIntroduction Types of Hazards CEC Code C22.1-98 CanadaInspection upon Receipt of Goods GeneralVisible External Damage Concealed DamageAPC Worldwide Customer Support Warranty Information Limited WarrantyWarranty Limitations Specification Product Overview and Technical DescriptionRectifier Parameter per rectifier 1TWF0500H54 Display + LED’s Alarm Card Layout ControllerSK10 SK11Alarms Available AlarmsAccess Rear Access Alarms Front Access Alarms Knockout PanelsMajor and Minor Alarms Alarm Description Major alarm Minor alarm SelectionCustomer Inputs Current Limit ProgrammingOutput Voltage Programming Battery Test Function Input Description Location Enable Function Input Description LocationTemperature Compensation Input Description Socket Pin System ControllerDimensions WeightMechanical Mounting Options Schematic Positive Earth ConfiguredNegative Earth Configured System Configuration DCM00K02W481DCM00K02W482 DCM00K02W483Installation Procedure Single PhaseRear Access Connection AC Primary SupplyFront Access Connection Terminal Block Cable GlandSingle Phase, AB Feed Front Access Connection 3 3 Phase Star Supply Front access connection 4 3 Phase Delta Supply Front access connection 1 10 GMT Fuses Rear Access DC DistributionAmbient Temperature 2 10 GMT Fuses Front Access3 4 Circuit Breakers Rear Access 4 4 Circuit Breakers Front Access 5 4 Cartridge Fuses Rear Access 6 4 Cartridge Fuses Front AccessRouting Of Cables Input cablesOutput Cables External Battery Installation Battery Back-up functionLVD Function Battery Connection Diagram System Output EarthingPowering up the MX06 40A Shelf Commissioning the SystemGeneral Manual Handling Procedure PreparationMethod Fault Finding / Symptoms Fault SymptomsService, Accessories & Spares Rectifier replacementController replacement