American Power Conversion DC Series Warranty Information, Limited Warranty, Warranty Limitations

Page 9

1.6 Warranty Information

1.6.1Limited Warranty

American Power Conversion (APC) warrants the DC MX06 40A Shelf to be free from defects in materials and workmanship for a period of two years from the date of purchase. It’s obligation under this warranty is limited to repairing or replacing, at it’s own sole option, any such defective products. This warranty does not apply to equipment that has been damaged by accident, negligence, or misapplication or has been altered or modified in any way. This warranty applies only to the original purchaser.

1.6.2Warranty Limitations

Except as provided herein, American Power Conversion makes no warranties, express or implied, including warranties of merchantability and fitness for a particular purpose.

Some jurisdictions do not permit limitation or exclusion of implied warranties; therefore, the aforesaid limitation(s) or exclusion(s) may not apply to the purchaser.

Except as provided above, in no event will APC be liable for direct, indirect, special, incidental, or consequential damages arising out of the use of this product, even if advised of the possibility of such damage.

Specifically, APC is not liable for any costs, such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, costs of substitutes, claims by third parties, or otherwise. This warranty gives you specific legal rights and you may also have other rights, which vary from state to state.

User Manual 990-9178A

Page 9 of 44

18th FEB 02

DC MX06 40A Shelf

Image 9
Contents DC Series MX06 40A Shelf DC MX06 40A Shelf Contents Issue Record Safety Precautions General InformationIntroduction CEC Code C22.1-98 Canada Types of HazardsGeneral Inspection upon Receipt of GoodsVisible External Damage Concealed DamageAPC Worldwide Customer Support Warranty Information Limited WarrantyWarranty Limitations Specification Product Overview and Technical DescriptionRectifier Parameter per rectifier 1TWF0500H54 Display + LED’s Controller Alarm Card LayoutSK10 SK11Alarms Available AlarmsAccess Front Access Alarms Knockout Panels Rear Access AlarmsAlarm Description Major alarm Minor alarm Selection Major and Minor AlarmsCustomer Inputs Current Limit ProgrammingOutput Voltage Programming Enable Function Input Description Location Battery Test Function Input Description LocationSystem Controller Temperature Compensation Input Description Socket PinDimensions WeightMechanical Mounting Options Positive Earth Configured SchematicNegative Earth Configured DCM00K02W481 System ConfigurationDCM00K02W482 DCM00K02W483Single Phase Installation ProcedureRear Access Connection AC Primary SupplyTerminal Block Cable Gland Front Access ConnectionSingle Phase, AB Feed Front Access Connection 3 3 Phase Star Supply Front access connection 4 3 Phase Delta Supply Front access connection DC Distribution 1 10 GMT Fuses Rear Access2 10 GMT Fuses Front Access Ambient Temperature3 4 Circuit Breakers Rear Access 4 4 Circuit Breakers Front Access 6 4 Cartridge Fuses Front Access 5 4 Cartridge Fuses Rear AccessInput cables Routing Of CablesOutput Cables External Battery Installation Battery Back-up functionLVD Function System Output Earthing Battery Connection DiagramPowering up the MX06 40A Shelf Commissioning the SystemGeneral Manual Handling Procedure PreparationMethod Fault Symptoms Fault Finding / SymptomsService, Accessories & Spares Rectifier replacementController replacement