American Power Conversion 240-320kW manual SmartSlot Accessories, Priority of SmartSlot devices

Page 35

External Connection

Some computer operating systems have built-in UPS monitoring. These systems require various hardware interfaces. Interface kits for all major operating systems that support UPS monitoring are available from your dealer.

APC SmartSlot for APC Silcon Series UPS's has been designed for reliable and maintenance- free service in combination with your American Power Conversion (APC) Silcon UPS Series uninterruptible power supply (UPS).

4.6.1 SmartSlot Accessories

SmartSlot at the front of the frame accomodate up to 3 accessory cards. Before installing any SmartSlot accessory, ensure it is a compatible "APC Silcon DUPSK" model.

1.Share-UPS TM, provides automatic shutdown of up to two additional servers.

2.Measure-UPS TM II, provides environmental information such as ambient temperature and humidity.

3.Call-UPS TM, works with an external modem to provide out-of-band UPS manegement

4.WEB/SNMP Management card, provides web based UPS management.

4.6.2 Multiple SmartSlot Installation - introduction

If your UPS configuration uses more than one SmartSlot device, you must install them in the correct order for them to work together properly.

Priority of SmartSlot devices:

A SmartSlot device with higher priority is to be placed in the SmartSlort accessory slot with the higher number. Refer to the following table.

Priority of APC accessories:

Install SmartSlot accessories as dictated by the following table. An accessory with higher priority is to be placed in the accessory slot with the higher number.

Acessory

P/N

Priority

Position

 

 

 

 

 

Web/SNMP Management Card

AP9606S

Highesst

High-numbered slot

 

 

 

 

 

Call-UPS® //

AP9608

Second-highest

 

 

 

 

 

 

 

 

 

 

 

 

Interface expander

AP9607

Second-lowest

 

 

 

 

 

 

 

 

 

 

 

 

Measure-UPS® //

AP9612T

Lowest

 

 

 

AP9612TH

 

Low-numbered

 

 

 

 

 

Installing accessories – procedure

To install accessories, perform the following steps:

1)Make sure that the APC Silcon UPS is powered off.

2)Install the SmartSlot accessories into the housings on the front of the chassis.

See the instructions supplied with the accessories and “Priority of APC accessories.”

If your UPS has one SmartSlot accessory slot

If your UPS has exactly one SmartSlot accessory slot, use this accessory slot for the SmartSlot device with the lowest priority.

990-4049

Installation Guide APC Silcon 240-320kW 480V UPS

35

Image 35
Contents Copyright 2001 APC Denmark ApS APC Silcon 240-320kW 480V UPS Installation GuideThank You Installation Guide APC Silcon 240-320kW 480V UPSSafety Symbols used in this manual Contents Installation Guide APC Silcon 240-320kW 480V UPS Tools IntroductionIntroduction Tools and EquipmentUnpacking/Identification of Equipment Unpacking/Identification of EquipmentMain UPS system Service Bypass PanelBattery Breaker Box Battery CabinetRemote Display Isolation TransformerSeismic Anchoring Nema 12 CoverRequirements on Site InstallationInstallation Dimensions and WeightUPS Cabinet Footprints FootprintsCOM COM Front Conduit Entrance Plate in bottom of the systemTop Cable Entry External Connection Connecting the UPSExternal Connection Connecting AC and DC Power Cables Dual Utility Connection Dual Utility Connection Seperation of AC from DC1 and DC2 Top or Bottom Cable Entry Dual and Single Utility Supply Working Principle of Single Utility 1 utility supply Working Principle of Dual Utility 2 utility suppliesSwitching from Dual to Single Utility Input Wiring Stud size M10 M12 Terminals Input Battery Output System earth TypeStud size Terminal Ground terminals Single Utility Dual Utility System Integration InterfaceSII Board Connecting the System Integration Interface Board SII-boardExternal Connection External Connection External Connection Parallel Board Parallel BoardExternal Control Cables Power CablesRelay Board Functions Relay Number Message Alarm Trigging EventsRelay Board Relays External Connection Cable Sizes Connections Communication Interface / Smart SlotSmartSlot for APC Silcon 240-320kW UPS Installing accessories procedure SmartSlot AccessoriesMultiple SmartSlot Installation introduction Priority of APC accessoriesInstallation in APC Silcon 240kW and 320kW Important Safety Instructions APC Silcon Battery CabinetsAPC Silcon Installation of BatteriesBattery Breaker Box See measurements Mounting and Connection of Battery Breaker BoxInterconnection Rear of enclosureUPS with External Battery via Battery Breaker Box UPS Installations in Computer RoomsS002 Choose either Emergency shutdown connection between EPO PrincipleUPS Principle diagramSupply Emergency Power Off EPO for UPSUtility Possible UPS operation Tripping Utility Possible UPS operation modes Tripping Supply Single configuration for Single UtilityParameters Parameter Setting CommentsProgramming ProgrammingProgramming Keys Programming Example Switch to Bypass OperationProgramming 326V System Configuration438V 346VProgramming Example Change Boost Charge Voltage to SeparateProgramming Programming Example Description of SettingsProgramming Parameters for Advanced Parallel Operation Battery Monitor Principle diagram Service Bypass Panel for single operation Options/AccessoriesOptions/Accessories Battery Breaker Box APC Silcon UPS System Integration Interface Mounting and Connecting Service Bypass Panel Options/Accessories Options/Accessories Mounting and Connecting Seismic Anchoring Mounting Seismic Anchoring Mounting Nema 12 Cover Nema 12 Cover IP31Standard Short-haul RS232 Modem Async Remote DisplayExtension of Remote Display Communication Distance Pin Connections for cable from host to ME800A-R2 Host Connections Without ConverterHost DTE Remote Display DTE Connections With ConverterScrews DP9-F Remote Display Power SupplyRemote Display Use Communication FaultRemote Display Setting Remote Display CablesIsolation Transformer Module Footprints Cabinets and DimensionsConnecting Isolation Transformer External Temperature Alarm CableIsolation Transformer Grounding 6.5.7.1 System Grounding Isolation Transformer Diagram Delta WYE configuration Dyn11Single Utility and Redundant System Dual Utility and Redundant System Dual Utility and Single SystemIntersystem Synchronization Unit ISU Intersystem Synchronization UnitIntersystem Synchronization Unit System ISU System Voltage 3x480V System SpecificationsSystem Specifications Technical DataAppendix Installation Planning DataAppendix Fepw TBS,SA RH,RHW Correction Factors APC Silcon Series Limited Factory Warranty WarrantyWarranty APC Denmark How to Contact APCHow to Contact APC APC Corporate