American Power Conversion 2200 manual Presentation, Front panel

Page 9

3.Presentation

3.1Front panel

With the unit plugged in, press the on/test button to turn on the unit and power the loads. See Sec. 5.1. On/test also activates the unit’s self-test and utility line voltage displays. See sections 5.3 and 5.6. The overload LED lights when the loads connected to the unit exceed the unit’s capacity. See section 6.2.

The battery charge/line voltage display shows the present battery charge as a percentage of battery capacity. See section 5.5. It also displays the voltage of the utility line. See section 5.6.

The on-batteryLED comes on when the unit is supplying battery power to the loads.

The replace battery LED comes on when the unit’s battery is no longer useful and must be replaced. See section 10.

Press the off button to turn off the unit and the load. See section 5.2.

The SmartBoost LED comes on when the unit is correcting a low utility voltage condition. The loads receive normal power.

The on-lineLED comes on when the unit is supplying utility power to the loads. The load display shows the power being drawn by the load. See section 5.4.

The SmartTrim LED comes on when the unit is correcting a high utility voltage condition. The loads receive normal power.

English

5

Image 9
Contents Smartups Part Number 990-7042A Revision Revised 7/97 Contents/Índice Page Introduction IntroductionThank you Please save the packaging materials Radio Frequency Interference VA 1400 VA VA and 3000 VA Intelligent Battery Management FeaturesComputer Interface and Accessory Slot Theory of OperationSafety Front panel Presentation3000 VA 1400 VA Rear Panel700 VA Placement InstallationInspection Protection StrategiesInstall Accessory Optional Charge the BatteryConnect to Utility Check the Site Wiring Fault Indicator Connect Ground Leads to Tvss Connector OptionalConnect the Loads Switch Off Switch OnOperation Self-testBattery Charge Bar Graph Load Bar GraphUtility Voltage Bar Graph Cold Start SmartBoost and SmartTrimVoltage Sensitivity Low Battery Warning IntervalAlarms Options Troubleshooting Service Replacement Batteries Replacing the BatteryBattery Replacement Procedure 450 through 1400 VA models Battery Replacement Procedure 2200 and 3000 VA models Storage Storage conditionsExtended storage English SpecificationsHow to Determine On-battery Run Time Typical On-Battery Run Time Versus Load, in Minutes Model User Configuration Items Obrigado IntroduçãoImportante Guarde a embalagemVA e 3000 VA Interferência de RadiofreqüênciaMétodo de Operação RecursosGerenciamento Inteligente de Baterias Interface do Computador e Slot de Acessórios SegurançaPainel frontal ApresentaçãoPainel Traseiro 2200 e 3000 VA1000 e 1400 VA 450 e 700 VA Inspeção InstalaçãoLocalização Estratégias de ProteçãoInstalação de Acessórios Opcional Conexão à Energia ExternaCarregue a Bateria Conecte as Cargas Verifique o Indicador de Falha da Fiação LocalConecte a Fiação de Aterramento ao Conector Tvss Opcional Ligar OperaçãoDesligar AutotesteIndicadores de Carga Indicadores de Carga da Bateria Indicadores de Voltagem ExternaSmartBoost e SmartTrim Sensibilidade da Voltagem Inicialização FriaModo de Desligamento Intervalo do Aviso de Bateria FracaCom Bateria AlarmesSobrecarga Bateria FracaVisão Geral OpçõesKits de Interface Slot de AcessóriosResolução de Problemas Assistência Técnica Aviso Substituição da BateriaSubstituição das Baterias Page Armazenamento Condições de Armazenamento11.2 Períodos Longos de Armazenamento Ajustável via software opcional EspecificaçõesComo Determinar o Tempo de Autonomia da Bateria Page Itens Configuráveis pelo Usuário Limited Warranty Page Technical Support Numbers