Epson RC170 manual Pendant to the Controller, How to Reset an Emergency Stop State

Page 11

1. Safety

1.3Emergency Stop

„Immediately press the EMERGENCY STOP switch whenever you suspect any danger.

The Operator Panel is equipped with an EMERGENCY STOP switch. Before operating the Operator Panel, make sure that the EMERGENCY STOP switch

 

on the Operator Panel functions properly. Operating the Operator Panel when

 

the switch does not function properly is extremely hazardous and may result in

WARNING

serious bodily injury and/or serious damage to the equipment, as the switch

cannot fulfill its intended function in an emergency.

 

 

Furthermore, the EMERGENCY STOP switch does not function when nothing is

 

displayed on the Operator Pendant screen for the disconnection of the Operator

 

Pendant to the Controller.

Press the EMERGENCY STOP switch to stop the program execution, and turn OFF the robot axis motors. The program, pause data and other data will not be destroyed.

When the EMERGENCY STOP switch is pressed, the Emergency Stop state is held both mechanically and electrically.

To resume operation, follow the procedure below to reset the emergency stop state.

How to Reset an Emergency Stop State

(1)Remove the cause of the Emergency Stop, and make sure that the robot can be operated safely when robot operation is resumed.

(2)Release the EMERGENCY STOP switch. To release a mechanical hold, turn the EMERGENCY STOP switch to the right.

(3)Display the program execution screen and touch the Reset button.

When the Emergency Stop is released, the “EMERGENCY STOP” on the Operator Panel Program Execution Screen turns OFF (displays).

OP1 Rev.1a

3

Image 11
Contents OP1 RC170 Option Operator Panel OP1 Rev.1a RC170 Option Operator Panel OP1Foreword Trademarks Manufacturer & Supplier Before Reading This ManualTable of Contents Programming for Operator Panel Conventions SafetySafety Precautions SafetyPage Pendant to the Controller How to Reset an Emergency Stop StateEmergency Stop Environmental Specifications SpecificationsSpecification Tables Electrical SpecificationsTouch Panel Function switchesEmergency Stop switch Part Names and FunctionsTool connector Specifications Power LampTeach Pendant connector Bypass Plug Hcom connectorExternal appearance with mounting metal hasps Appearance and DimensionsAppearance without mounting metal hasps Mounting Metal Hasps Dimensions Panel Cutout DimensionsGasket InstallationInstallation UnpackingMounting Holes Installing Operator Panel Connecting Cables Teach Pendant Connection Operation OperationBasic Operations Startup screen Startup ScreenOperator Panel screen image Program Execution Screen Program number Operation Serious Error stateError state How to set the Operator Panel to a control devicePause program Cancel programReset Execute programTask Monitor Screen Monitor screen 32-bit display OP1 Rev.1a I/O Monitor ScreenOperation Monitor screen 8-bit display System History Screen Application Screen Application screen text string input Application screen numerical value inputStartup screen Setup screen Language Setup ScreenOperation Change display after program execution Programming for Operator Panel Programming for Operator PanelDisplay on Operator Panel Simple Display ProgramDisplay Device Executing the display device selection commandData Input from Operator Panel Value Input String Input About Display Language Maintenance and Inspection Maintenance and InspectionContrast Adjustment Brightness Adjustment Case and Display Cleaning Firmware UpdateApproximately 3.0 mm from the groove OP1 Rev.1a Replacement ProcedureAbout Gasket Gasket evenly sticking outMaintenance Parts List Regular Maintenance InspectionBacklight Replacement