4. Operation

I/O Monitor screen (8-bit display)

“*” (asterisk) is displayed before the signal for remote setting to separate remote setting and I/O label.

In the 32-bit display, you can touch the currently displayed I/O column and temporarily confirm the I/O label in the popup window. The popup window disappears by touching.

Touching the “INPUT”, “OUTPUT” or “MEMORY” area displayed at the top left of the screen successively switches the display in the following order: I/O input → I/O output → memory I/O.

An ON (1) state is indicated as “”, and an OFF (0) state is indicated as “”.

The I/O to be displayed can be moved by eight bits by touching the <←> or <→> button.

You can touch the I/O number to directly specify the number.

Switches to the 32-bit display.

Switches to the 8-bit display.

When inputs and outputs that are not installed are displayed, the display will show all OFF.

OP1 Rev.1a

21

Image 29
Contents OP1 RC170 Option Operator Panel OP1 Rev.1a RC170 Option Operator Panel OP1Foreword Trademarks Manufacturer & Supplier Before Reading This ManualTable of Contents Programming for Operator Panel Safety Precautions SafetySafety ConventionsPage Pendant to the Controller How to Reset an Emergency Stop StateEmergency Stop Specification Tables SpecificationsElectrical Specifications Environmental SpecificationsEmergency Stop switch Function switchesPart Names and Functions Touch PanelTeach Pendant connector Bypass Plug Specifications Power LampHcom connector Tool connectorExternal appearance with mounting metal hasps Appearance and DimensionsAppearance without mounting metal hasps Mounting Metal Hasps Dimensions Panel Cutout DimensionsInstallation InstallationUnpacking GasketMounting Holes Installing Operator Panel Connecting Cables Teach Pendant Connection Operation OperationBasic Operations Startup screen Startup ScreenOperator Panel screen image Program Execution Screen Error state Operation Serious Error stateHow to set the Operator Panel to a control device Program numberReset Cancel programExecute program Pause programTask Monitor Screen Monitor screen 32-bit display OP1 Rev.1a I/O Monitor ScreenOperation Monitor screen 8-bit display System History Screen Application Screen Application screen text string input Application screen numerical value inputStartup screen Setup screen Language Setup ScreenOperation Change display after program execution Display on Operator Panel Programming for Operator PanelSimple Display Program Programming for Operator PanelDisplay Device Executing the display device selection commandData Input from Operator Panel Value Input String Input About Display Language Maintenance and Inspection Maintenance and InspectionContrast Adjustment Brightness Adjustment Case and Display Cleaning Firmware UpdateAbout Gasket Replacement ProcedureGasket evenly sticking out Approximately 3.0 mm from the groove OP1 Rev.1aMaintenance Parts List Regular Maintenance InspectionBacklight Replacement