Epson RC170 Specification Tables, Electrical Specifications, Environmental Specifications

Page 12

2. Specifications

2. Specifications

2.1Specification Tables

2.1.1Electrical Specifications

Item

Specifications

Rated voltage

DC 24 V

Voltage range

DC 21.6 to 26.4 V

Power consumption

7 W or less

Dielectric strength

AC 500 V 20 mA per minute (across charger and FG terminals)

Insulation resistance

500 VDC 20 MΩ or more (across charger and FG terminals)

2.1.2 Environmental Specifications

Item

Specifications

Ambient temperature

5 to 40 deg C (with minimal variation)

(in panel and at sides of

 

display screen)

 

Storage ambient

−25 to 55 deg C

temperature

 

Operating ambient

20 to 80% (no condensation)

humidity

 

Storage ambient

20 to 80% (no condensation)

humidity

 

Dust

0.1 mg/m3 or less (no conductive dust)

Contamination level

2

Corrosive gasses

Free of corrosive gasses

Air pressure resistance

800 to 1114 hPa (Max. 2000 m)

(operation altitude)

 

Noise resistance

1 kV (EN61000-4-4)

Electrostatic discharge

4 kV (EN61000-4-2 level 2)

immunity

 

2.1.3 Appearance Specifications

Item

Specifications

Protective structure*

JEM1030 IP65 or equivalent NEMA#250 TYPE4X/12

External dimensions

W215 mm ⋅ H155 mm ⋅ D46 mm (excluding connector hood)

Weight

Approx. 800 g (Including Bypass Plug. Excluding the cable.

Cooling method

Air-cooling without blower

*The protective structure is for the front part when the Operator Panel is installed. Though conformity has been confirmed under applicable testing conditions, use under all environments is not guaranteed. Before you start to use the Operator Panel, confirm use in the operating environment. Also, gasket that is used for long periods of time or once has been installed on the panel is scratched or dirty, and may cause lose sufficient protection performance. To ensure consistent protection performance, replace the gasket periodically.

4

OP1 Rev.1a

Image 12
Contents OP1 RC170 Option Operator Panel OP1 Rev.1a OP1 RC170 Option Operator PanelForeword Trademarks Before Reading This Manual Manufacturer & SupplierTable of Contents Programming for Operator Panel Safety Safety PrecautionsSafety ConventionsPage How to Reset an Emergency Stop State Emergency StopPendant to the Controller Specifications Specification TablesElectrical Specifications Environmental SpecificationsFunction switches Emergency Stop switchPart Names and Functions Touch PanelSpecifications Power Lamp Teach Pendant connector Bypass PlugHcom connector Tool connectorAppearance and Dimensions Appearance without mounting metal haspsExternal appearance with mounting metal hasps Panel Cutout Dimensions Mounting Metal Hasps DimensionsInstallation InstallationUnpacking GasketMounting Holes Installing Operator Panel Connecting Cables Teach Pendant Connection Operation Basic OperationsOperation Startup Screen Operator Panel screen imageStartup screen Program Execution Screen Operation Serious Error state Error stateHow to set the Operator Panel to a control device Program numberCancel program ResetExecute program Pause programTask Monitor Screen I/O Monitor Screen Monitor screen 32-bit display OP1 Rev.1aOperation Monitor screen 8-bit display System History Screen Application Screen Application screen numerical value input Application screen text string inputSetup Screen Startup screen Setup screen LanguageOperation Change display after program execution Programming for Operator Panel Display on Operator PanelSimple Display Program Programming for Operator PanelExecuting the display device selection command Data Input from Operator PanelDisplay Device Value Input String Input About Display Language Maintenance and Inspection Contrast AdjustmentMaintenance and Inspection Brightness Adjustment Firmware Update Case and Display CleaningReplacement Procedure About GasketGasket evenly sticking out Approximately 3.0 mm from the groove OP1 Rev.1aRegular Maintenance Inspection Backlight ReplacementMaintenance Parts List