4. Operation

4.4 Task Monitor Screen

The Task Monitor screen allows you to monitor the states of each task. By confirming the current state of each task, you can gain hints as to which signal the robot is waiting for (i.e. why the robot has stopped when it has stopped due to an interlock or signal standby).

You can select between a screen that displays all 16 tasks and a screen that displays eight tasks at a time. In the 16-task display screen, you can confirm the state of each task and line number. In the 8-task display screen, the name of the currently executing function is also displayed.

Task Monitor screen (16-task display)

Task Monitor screen (8-task display)

In the 16-task list display, a popup window that shows the function names of the eight tasks appears by touching the left or right side of the display screen. The popup window disappears by touching.

In the 8-task display, you can switch the tasks to display by the page switch button at the bottom right of the display.

Switches to the 16-task list display.

Switches to the 8-task list display. To switch between tasks 1 to 8 and tasks 9 to 16, touch the page switch button at the bottom right of the display.

OP1 Rev.1a

19

Image 27
Contents OP1 RC170 Option Operator Panel OP1 Rev.1a RC170 Option Operator Panel OP1Foreword Trademarks Manufacturer & Supplier Before Reading This ManualTable of Contents Programming for Operator Panel Conventions SafetySafety Precautions SafetyPage How to Reset an Emergency Stop State Emergency StopPendant to the Controller Environmental Specifications SpecificationsSpecification Tables Electrical SpecificationsTouch Panel Function switchesEmergency Stop switch Part Names and FunctionsTool connector Specifications Power LampTeach Pendant connector Bypass Plug Hcom connectorAppearance and Dimensions Appearance without mounting metal haspsExternal appearance with mounting metal hasps Mounting Metal Hasps Dimensions Panel Cutout DimensionsGasket InstallationInstallation UnpackingMounting Holes Installing Operator Panel Connecting Cables Teach Pendant Connection Operation Basic OperationsOperation Startup Screen Operator Panel screen imageStartup screen Program Execution Screen Program number Operation Serious Error stateError state How to set the Operator Panel to a control devicePause program Cancel programReset Execute programTask Monitor Screen Monitor screen 32-bit display OP1 Rev.1a I/O Monitor ScreenOperation Monitor screen 8-bit display System History Screen Application Screen Application screen text string input Application screen numerical value inputStartup screen Setup screen Language Setup ScreenOperation Change display after program execution Programming for Operator Panel Programming for Operator PanelDisplay on Operator Panel Simple Display ProgramExecuting the display device selection command Data Input from Operator PanelDisplay Device Value Input String Input About Display Language Maintenance and Inspection Contrast AdjustmentMaintenance and Inspection Brightness Adjustment Case and Display Cleaning Firmware UpdateApproximately 3.0 mm from the groove OP1 Rev.1a Replacement ProcedureAbout Gasket Gasket evenly sticking outRegular Maintenance Inspection Backlight ReplacementMaintenance Parts List