Toshiba RKP004Z Operation. Operationby copy functionin a copy function, VFAS1 VFPS1

Page 28

8. Operation. Operationby copy functionin a copy function

The copy function can be used when "Copy" is displayed on the upper part of the F3 key. The copy function works by the latest combination of LCD Remote Keypad (RKP004Z rev.2 or later) with the Inverter version of APP-CPU is V136 or more of VFAS1, V614 or more of VFPS1. When either is old, this function does not work.

 

 

 

 

 

Version of APP-CPU

 

 

Limitation in copy function use

VFAS1

VFPS1

 

V134

 

V136

V612

V614

 

 

 

 

 

 

 

or less

 

or more

or less

or more

 

LCD type form

RKP004Z-1or0

Disabled

 

Disabled

Disabled

Disabled

 

 

After RKP004Z-2

Disabled

 

Enabled

Disabled

Enabled

Moreover, it is not possible to copy

normally in

the following

cases even

if the copy

function can be used.

 

 

 

 

 

1)It is not possible to copy, when the inverter form differs,.

2)It is not possible to copy to the inverter while driving.

3)It is not possible to copy, when a minimum unit of the frequency is different.

4)It is necessary to reset up the parameters after the copy when copying between the inverters from which capacity differs.

5)It is necessary to reset power supply after the copy when the unit of time differs.

„ Explanation of the top window

 

 

Display of

 

 

Display of

• Display of commands executed:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

commands

 

 

operating status

“FWD” or “REV” is displayed to indicate the direction of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

rotation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Top View Mode

 

 

 

 

The operation frequency is displayed in the form of

 

 

FWD 60.0 Hz

 

 

 

 

RUN

 

††. †Hz.”

 

 

 

 

60.0 Hz

 

• Display of operating status:

 

 

 

 

 

“RUN” is displayed during operation.

 

 

 

 

 

“STOP” is displayed during a stop.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Overheat alarm

 

 

 

 

 

“Trip” is displayed in the event of tripping.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Quick

 

Lng

 

Copy

---

 

 

• Display of output frequency:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The operation frequency is displayed in the form of

 

 

F1

 

F2

 

F3

 

 

††. †Hz.”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Display of output frequency

• Display of alarm/tripping:

 

 

 

 

 

 

 

 

 

 

 

 

Display of alarm/tripping

If an error or tripping occurs, an error or trip code is displayed.

 

 

 

 

 

 

 

 

 

 

• Display of error/tripping message:

 

 

 

Display of error/tripping message

If an error or tripping occurs, an error or trip message is displayed

Functions of function keys

F1Switches between Quick mode and Standard Setting mode

F2 Brings you to the Language selection window.

F3Brings you to Copy mode window.

8-1

Image 28
Contents LCD Remote Keypad „ Explanation of model code Introduction„ Check product purchase Introduction „ Optional products Model numberSafetyprecautionsprecautions Explanation of markings „ Limitation of useSafety precautions „ Handling in general „ Transportation and installation„ Disposal Safety precautions „ Operations„ Notes on operations Contents Names. Namesand functionsand functions Names and functions „ LCD panelNames and functions „ About the change of parameter settings Installing the remote keypad to the inverter Installing the remote keypad to the board optional Installing the LCD remote keypadInverter unit Remote control optionalRemote keypad Language Selection window appears on the screen インバータ⇒パネルTop View Mode Parameter Setup ModeStatus Monitor Mode 54. .標About準モニタモードavailable modesOperation. in Top View Modein Top View Mode Setting a panel operation frequency„ Explanation of the top window Functions of function keysUsing an Easy key function „ To change the frequency during operationOperation in Top View Mode Always Quick mode parameter PSEL=2Operation Panel and Remote When used with a VF-AS1 inverter Operation Panel and Remote When used with a VF-PS1 inverterOperation in Top View Mode Peak/Minimum Hold setting Selecting a language to be displayedPress the F2 Lng key Select/confirm the desired language with the control dialPerforming jog run Press the F4 key to carry out jog runEmergency stop/reset operation 60.0 HzOperation. in Parameter inSetupParameterModeSetup Mode „ When Quick mode is selectedSelect/confirm History function using the control dial „ In this window, settings can be changedOperation in Parameter Setup Mode Setting a basic parameterSelect/confirm Basic parameters using the control dial Select/confirm Extended parameters using the control dial Setting an extended parameterChange the parameter setting Select/confirm Changed Parameters using the control dial [CMOd]Operation. in Status Monintor modeStatus Monitor Mode Items displayed Description DisplayDisplaying details of an item monitored Operation. Operationby copy functionin a copy function VFAS1 VFPS1Copy to LCD Operation by a copy functionDisplay of copy loading(fixed screen) Display of copy finishCopy to inverter [Copy to the inverter]Confirm a memory information Function Key Display Position WarrantyList of function key functionsFunction Reference Specifications 710. 状態. モSpecificationsニタモードでの操作„ Outside dimensions unit mm Before. Beforemaking a servicemakingcall a service call Problems Possible causes RemediesBefore making a service call Warranty. Warranty