Toshiba RKP004Z instruction manual Names. Namesand functionsand functions

Page 8

1. Names. Namesand functionsand functions

(2) (3) (4) (5)

(1)

(9)

(6)

(8)

(7)

(10)

(1)LCD panel

For an explanation of windows displayed, see the next page.

(2)to (5) [F1] to [F4] function keys

The function of each function key varies depending on the window currently displayed.

Refer to the next page and “8. List of function key functions”

(6)[ESC] key

Each time this key is pressed, modes change from one to another. Also, pressing this key brings you back to the window one level higher in the window hierarchy.

(7)[FWD/REV] key

Each time this key is pressed, the direction of operation changes between forward run and reverse run.

(To use this key, parameter settings need to be changed. Refer to page 1-3.)

(8)[RUN] key Starts operation.

(To use this key, parameter settings need to be changed. Refer to page 1-3.)

(9)[STOP/RESET] key Stops operation.

(To use this key, parameter settings need to be changed. Refer to page 1-3.)

In case the inverter has tripped, pressing this key twice in a row resets the inverter.

* If multiple commands are entered by pressing the three keys [F2], [F3] and [F4] or [ESC], [FWD] and [RUN] in rapid succession, a stop command will be issued instead to stop operation.

(10)Control dial *1

In a menu window, turn the dial clockwise or counterclockwise to select a menu item (the item selected is highlighted) and press the dial to confirm the menu item selected.

Turn the dial clockwise (+) to select an item that follows the item currently selected. Turn the dial counterclockwise (-) to select an item that precedes the item currently selected.

Selecting a menu item by turning the dial clockwise or counterclockwise and confirm the item selected by pressing the dial are referred to as “select/confirm an item.”

1-1

Image 8
Contents LCD Remote Keypad „ Check product purchase Introduction„ Explanation of model code Introduction „ Optional products Model numberSafetyprecautionsprecautions Explanation of markings „ Limitation of useSafety precautions „ Handling in general „ Transportation and installation„ Notes on operations Safety precautions „ Operations„ Disposal Contents Names. Namesand functionsand functions Names and functions „ LCD panelNames and functions „ About the change of parameter settings Installing the remote keypad to the inverter Installing the remote keypad to the board optional Installing the LCD remote keypadRemote keypad Remote control optionalInverter unit Language Selection window appears on the screen インバータ⇒パネルTop View Mode Parameter Setup ModeStatus Monitor Mode 54. .標About準モニタモードavailable modesOperation. in Top View Modein Top View Mode Setting a panel operation frequency„ Explanation of the top window Functions of function keysUsing an Easy key function „ To change the frequency during operationOperation in Top View Mode Always Quick mode parameter PSEL=2Operation Panel and Remote When used with a VF-AS1 inverter Operation Panel and Remote When used with a VF-PS1 inverterOperation in Top View Mode Peak/Minimum Hold setting Selecting a language to be displayedPress the F2 Lng key Select/confirm the desired language with the control dialPerforming jog run Press the F4 key to carry out jog runEmergency stop/reset operation 60.0 HzOperation. in Parameter inSetupParameterModeSetup Mode „ When Quick mode is selectedSelect/confirm History function using the control dial „ In this window, settings can be changedSelect/confirm Basic parameters using the control dial Setting a basic parameterOperation in Parameter Setup Mode Change the parameter setting Setting an extended parameterSelect/confirm Extended parameters using the control dial Select/confirm Changed Parameters using the control dial [CMOd]Operation. in Status Monintor modeStatus Monitor Mode Items displayed Description DisplayDisplaying details of an item monitored Operation. Operationby copy functionin a copy function VFAS1 VFPS1Copy to LCD Operation by a copy functionDisplay of copy loading(fixed screen) Display of copy finishCopy to inverter [Copy to the inverter]Confirm a memory information Function Reference WarrantyList of function key functionsFunction Key Display Position „ Outside dimensions unit mm 710. 状態. モSpecificationsニタモードでの操作Specifications Before. Beforemaking a servicemakingcall a service call Problems Possible causes RemediesBefore making a service call Warranty. Warranty