Toshiba B-SA4T installation manual Upper Sensor Ass’y Upper Sensor Lever

Page 45

INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT

EO15-33001A

(Revision Date: Feb. 25, 2008)

8. RFID Module: B-SA704-RFID-U2-EU-R

3.Slightly push the Upper Sensor Lever inside (1), and open the Upper Sensor Ass’y (2).

Upper Sensor Ass’y

(2)

Upper Sensor Lever

(1)

4.Pushing the tabs on the rear of the Media Sensor Block toward the front of the printer, slightly lift the back of the Media Sensor Block, and remove it toward the printer back.

Tab

Media Sensor Block

Tab

5.Turn over the Media Sensor Block, and secure the Antenna Ass’y with the supplied three Tapping

Screws.

Sensor Block

Tapping Screw M-3x8

 

Antenna Ass’y

Tapping Screw M-3x8

 

8- 5

Image 45
Contents SA4T Series Table of Contents SA204-QM / B-SA204-QM-R Cutter Module100 Front Cover Hinge Screw Close the Cutter Module Cover System Mode ManualSA204P-QM-R Open the Front Cover, and remove the Connector CoverSet Screw Cutter Unit Connector 3x6 Screw Ground Wire Cutter Harness Guide Roller 1 pc Installation Manual 1 copy Strip ModuleSA904-H-QM-R 100 Front Cover HingeScrew Close the Strip Unit Attaching the Cutter System Mode Settings for Stripping PET Labels 3ADJUST SET Feed ADJ 2PARAMETER SET Back Speed STD SMW-3x6 Screw 4 pcs SA904P-H-QM-R100 Front Cover HingeStopper Close the Strip Unit Opening Strip Unit Cutter FCC/IC Sticker 1 pc Wireless LAN Module B-SA704-WLAN-QMSA4TM SA4TP Remove the two SMW-3x6 screws from the back of the printerRemove the SMW-3x8 screw to detach the Cable Clamp Remove the two SMW-3x6 screws to detach the Blind PlateCopper foil Re-attach the Side Panel to the printer Country Code Serial Interface Board B-SA704-RS-QM-R SMW-3x6 Screw 3 pcsRemove the two screws from the back of the printer Remove the two screws to detach the Blind Plate Fit the Locking Support into the Main PC Board SMW-3x6 Locking Support Dpi Print Head Kit B-SA704-TPH3-QM-R Packing ListNever loosen or remove these screws Disconnect the Print Head Cable from the Print Head Installation ProcedureReal Time Clock B-SA704-RTC-QM-R Battery Socket Lithium Battery Battery Sticker Care must be taken not to catch Connect the Interface Cable to CN501 on the Main PC BoardSet the date and time using the following procedure System Setting Date and Time SettingWith the Feed or Restart key Expansion I/O Board B-SA704-IO-QM-R SMW-3x6 Screw Blind Plate Attach the Side Panel, removed in , back to the printer Connect the Interface Cable to CN4 on the Main PC BoardApplicable Model Rfid Module B-SA704-RFID-U2-EU-RPacking List Outline of the introduction of an Rfid Kit Side Panel Hook Upper Sensor Ass’y Upper Sensor Lever Connect the Interface Cable to CN6 on the Main PC Board. CN6 Attach the Cable Clamp to the position shown below Connect the Interface Cable to the Rfid Module Re-place the Media Sensor Block When Short-Pitch Rfid Tags 20mm are usedMedia Guide Module None Rfid Module SettingsEPC C1 Gen2 Cycle TIM ADJ Retry +00 Value AGC Threshold Setting From the previous 3132333435363738 39304142 0A Identification of The Rfid Module B-SA704-RFID-U2-EU-R Service No. LabelSerial No. Label 0500-02 08 5 D