8. RFID Module: B-SA704-RFID-U2-EU-R

Continued from the previous page

3132333435363738

39304142 (0A)

[FEED], [RESTART]

<10>RFID

Read data is displayed.

Data in parentheses ( ) is the AGC value expressed in hex. code. Write down this value.

Press the [FEED] and [RESTART] keys to return to the RFID Setting Menu (”<10>RFID”).

3)Set an AGC threshold of data write.

Set a value which is lower than the AGC value obtained by a read test by 1 or 2, taking variation of RFID tags in performance into consideration.

Example

<10>RFID

[PAUSE]

<10>RFID

 

Q VALUE

2

[FEED] or [RESTART]

<10>RFID

 

Q VALUE

2

When ”<10>RFID” is displayed, press the [PAUSE] key until the Q value setting menu is displayed.

Choose “2” with the [FEED] or [RESTART] key.

When “2” is already chosen, go to the AGC threshold for data write setting menu.

 

 

 

15

 

 

 

 

[RESTART]

 

 

 

 

 

 

 

2 (Default)

 

[FEED]

 

 

 

 

 

 

0

[PAUSE]

<10>RFID

 

WT AGC

11

[FEED] or [RESTAT]

<10>RFID

 

 

WT AGC

9

 

 

 

 

 

 

[PAUSE]

 

 

 

 

 

 

 

 

 

<10>RFID

 

 

WT MIN AGC

11

[FEED] or [RESTAT]

<10>RFID

WT MIN AGC 9

[PAUSE]

<10>RFID

Press the [PAUSE] key.

AGC threshold for data write setting menu is displayed.

Choose a threshold value (decimal number) with the [FEED] or [RESTART] key.

When the measured AGC is 10 (0A), for example, choose “9” (a value lower than the measured AGC by 1 or 2).

 

 

 

 

 

15

 

 

 

 

 

 

[RESTART]

 

 

 

 

 

 

11 (Default)

 

 

[FEED]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

Press the [PAUSE] key.

AGC threshold lower limit for retry setting menu is displayed. Choose a lower limit (decimal number) with the [FEED] or [RESTART] key.

Usually, choose the same value with the AGC threshold for data write (WT AGC).

 

 

15

 

 

[RESTART]

 

 

11 (Default)

 

 

 

 

[FEED]

 

 

0

 

 

Press the [PAUSE] key.

RFID Setting Menu (”<10>RFID”) is displayed.

An AGC threshold setting is completed.

8- 17

Image 57
Contents SA4T Series Table of Contents SA204-QM / B-SA204-QM-R Cutter Module100 Front Cover Hinge Screw Close the Cutter Module Cover System Mode ManualSA204P-QM-R Open the Front Cover, and remove the Connector CoverSet Screw Cutter Unit Connector 3x6 Screw Ground Wire Cutter Harness Guide Roller 1 pc Installation Manual 1 copy Strip ModuleSA904-H-QM-R 100 Front Cover HingeScrew Close the Strip Unit Attaching the Cutter System Mode Settings for Stripping PET Labels 3ADJUST SET Feed ADJ 2PARAMETER SET Back Speed STD SMW-3x6 Screw 4 pcs SA904P-H-QM-R100 Front Cover HingeStopper Close the Strip Unit Opening Strip Unit Cutter FCC/IC Sticker 1 pc Wireless LAN Module B-SA704-WLAN-QMSA4TM SA4TP Remove the two SMW-3x6 screws from the back of the printerRemove the SMW-3x8 screw to detach the Cable Clamp Remove the two SMW-3x6 screws to detach the Blind PlateCopper foil Re-attach the Side Panel to the printer Country Code Serial Interface Board B-SA704-RS-QM-R SMW-3x6 Screw 3 pcsRemove the two screws from the back of the printer Remove the two screws to detach the Blind Plate Fit the Locking Support into the Main PC Board SMW-3x6 Locking Support Dpi Print Head Kit B-SA704-TPH3-QM-R Packing ListNever loosen or remove these screws Disconnect the Print Head Cable from the Print Head Installation ProcedureReal Time Clock B-SA704-RTC-QM-R Battery Socket Lithium Battery Battery Sticker Care must be taken not to catch Connect the Interface Cable to CN501 on the Main PC BoardSet the date and time using the following procedure System Setting Date and Time SettingWith the Feed or Restart key Expansion I/O Board B-SA704-IO-QM-R SMW-3x6 Screw Blind Plate Attach the Side Panel, removed in , back to the printer Connect the Interface Cable to CN4 on the Main PC BoardApplicable Model Rfid Module B-SA704-RFID-U2-EU-RPacking List Outline of the introduction of an Rfid Kit Side Panel Hook Upper Sensor Ass’y Upper Sensor Lever Connect the Interface Cable to CN6 on the Main PC Board. CN6 Attach the Cable Clamp to the position shown below Connect the Interface Cable to the Rfid Module Re-place the Media Sensor Block When Short-Pitch Rfid Tags 20mm are usedMedia Guide Module None Rfid Module SettingsEPC C1 Gen2 Cycle TIM ADJ Retry +00 Value AGC Threshold Setting From the previous 3132333435363738 39304142 0A Identification of The Rfid Module B-SA704-RFID-U2-EU-R Service No. LabelSerial No. Label 0500-02 08 5 D