INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT

EO15-33001A

(Revision Date: Jan. 19, 2006)

6. Real Time Clock: B-SA704-RTC-QM-R

System Setting (Date and Time Setting)

Set the date and time using the following procedure.

NOTE: Make sure that the printer version is V1.2 or greater. The real time clock is not supported by V1.1 or older.

1.Turn on the printer. “ONLINE” will be displayed on the LCD.

2.Press the [PAUSE] key to turn the printer to pause state.

3.Hold down the [RESTART] key until the printer enters the system mode.

NOTE: For details of the system mode, refer to the B-SA4T Series Owner’s Manual stored in the CD-ROM supplied with the printer.

4.When “<1>RESET” is displayed on the LCD, press the [RESTART] key until “<8>RTC SET” appears.

5.Press the [PAUSE] key. The date currently stored in the real time clock is displayed.

6.Pressing the [PAUSE] key enables changing the Year.

7.Set the Year with the [FEED] or [RESTART] key. Pressing the [PAUSE] key fixes the Year and causes the cursor to move to the Month.

8.Set the Month with the [FEED] or [RESTART] key. Pressing the [PAUSE] key fixes the Month and causes the cursor to move to the Day.

9.Set the Day with the [FEED] or [RESTART] key. Press the [PAUSE] key to fix the Day. Then, the time currently stored in the real time clock is displayed.

Power ON

ONLINE

B-SA4T V1.2

PAUSE

PAUSE

B-SA4T V1.2

RESTART

<1>RESET

RESTART

<8>RTC SET

PAUSE

<8>RTC SET DATE 05/01/01

PAUSE

<8>RTC SET DATE Y 05/01/01

Year

 

 

 

 

 

 

 

PAUSE

 

 

 

 

 

 

 

<8>RTC SET DATE M 06/01/01

PAUSE

<8>RTC SET DATE D 06/03/01

PAUSE

<8>RTC SET TIME 00/00/00

FEED

 

RESTART

 

 

 

Month

FEED

 

RESTART

 

 

 

Day

FEED

 

RESTART

 

 

 

(Continued.)

6- 5

Image 36
Contents SA4T Series Table of Contents Cutter Module SA204-QM / B-SA204-QM-R100 Front Cover Hinge Screw System Mode Manual Close the Cutter Module CoverOpen the Front Cover, and remove the Connector Cover SA204P-QM-RSet Screw Cutter Unit Connector 3x6 Screw Ground Wire Cutter Harness Guide Roller 1 pc Installation Manual 1 copy Strip ModuleSA904-H-QM-R 100 Front Cover HingeScrew Close the Strip Unit Attaching the Cutter System Mode Settings for Stripping PET Labels 3ADJUST SET Feed ADJ 2PARAMETER SET Back Speed STD SA904P-H-QM-R SMW-3x6 Screw 4 pcs100 Front Cover HingeStopper Close the Strip Unit Opening Strip Unit Cutter Wireless LAN Module B-SA704-WLAN-QM FCC/IC Sticker 1 pcRemove the two SMW-3x6 screws from the back of the printer SA4TM SA4TPRemove the two SMW-3x6 screws to detach the Blind Plate Remove the SMW-3x8 screw to detach the Cable ClampCopper foil Re-attach the Side Panel to the printer Country Code Serial Interface Board B-SA704-RS-QM-R SMW-3x6 Screw 3 pcsRemove the two screws from the back of the printer Remove the two screws to detach the Blind Plate Fit the Locking Support into the Main PC Board SMW-3x6 Locking Support Dpi Print Head Kit B-SA704-TPH3-QM-R Packing ListNever loosen or remove these screws Installation Procedure Disconnect the Print Head Cable from the Print HeadReal Time Clock B-SA704-RTC-QM-R Battery Socket Lithium Battery Battery Sticker Connect the Interface Cable to CN501 on the Main PC Board Care must be taken not to catchSystem Setting Date and Time Setting Set the date and time using the following procedureWith the Feed or Restart key Expansion I/O Board B-SA704-IO-QM-R SMW-3x6 Screw Blind Plate Connect the Interface Cable to CN4 on the Main PC Board Attach the Side Panel, removed in , back to the printerRfid Module B-SA704-RFID-U2-EU-R Applicable ModelPacking List Outline of the introduction of an Rfid Kit Side Panel Hook Upper Sensor Ass’y Upper Sensor Lever Connect the Interface Cable to CN6 on the Main PC Board. CN6 Attach the Cable Clamp to the position shown below Connect the Interface Cable to the Rfid Module When Short-Pitch Rfid Tags 20mm are used Re-place the Media Sensor BlockMedia Guide Rfid Module Settings Module NoneEPC C1 Gen2 Cycle TIM ADJ Retry +00 Value AGC Threshold Setting From the previous 3132333435363738 39304142 0A Service No. Label Identification of The Rfid Module B-SA704-RFID-U2-EU-RSerial No. Label 0500-02 08 5 D