Toshiba B-SA4T installation manual Opening Strip Unit Cutter

Page 19
SMW-3x6 Screw

INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT

EO15-33001A

(Revision Date: Jan. 19, 2006)

2. Strip Module

Attaching the Cutter

The enclosed cutter is used to tear off the batch-issued labels. Attach the cutter with the two SMW-3x6 screws as shown in the picture below. Insert the leading edge of the labels into the opening under the cutter.

Opening

Strip Unit

Cutter

Edge

NOTE: Depending on the backing paper types, tearing off the backing paper against the slot of the strip module cover may cause it to wind onto the inner rollers. It is advisable to tear off or cut the backing paper outside the strip module cover.

Slot

How to use the Guide Roller

When issuing the label with the length of 50 mm or more, fit the guide roller to the center of the strip module cover to prevent the stripped label from sticking to the cover.

Opening

Guide Roller

Strip Module Cover

NOTE: Regarding the system mode setting for use of PET paper, refer to Section 2.1.

2- 11

Image 19
Contents SA4T Series Table of Contents SA204-QM / B-SA204-QM-R Cutter Module100 Front Cover Hinge Screw Close the Cutter Module Cover System Mode ManualSA204P-QM-R Open the Front Cover, and remove the Connector CoverSet Screw Cutter Unit Connector 3x6 Screw Ground Wire Cutter Harness Strip Module Guide Roller 1 pc Installation Manual 1 copySA904-H-QM-R 100 Front Cover HingeScrew Close the Strip Unit Attaching the Cutter System Mode Settings for Stripping PET Labels 3ADJUST SET Feed ADJ 2PARAMETER SET Back Speed STD SMW-3x6 Screw 4 pcs SA904P-H-QM-R100 Front Cover HingeStopper Close the Strip Unit Opening Strip Unit Cutter FCC/IC Sticker 1 pc Wireless LAN Module B-SA704-WLAN-QMSA4TM SA4TP Remove the two SMW-3x6 screws from the back of the printerRemove the SMW-3x8 screw to detach the Cable Clamp Remove the two SMW-3x6 screws to detach the Blind PlateCopper foil Re-attach the Side Panel to the printer Country Code SMW-3x6 Screw 3 pcs Serial Interface Board B-SA704-RS-QM-RRemove the two screws from the back of the printer Remove the two screws to detach the Blind Plate Fit the Locking Support into the Main PC Board SMW-3x6 Locking Support Packing List Dpi Print Head Kit B-SA704-TPH3-QM-RNever loosen or remove these screws Disconnect the Print Head Cable from the Print Head Installation ProcedureReal Time Clock B-SA704-RTC-QM-R Battery Socket Lithium Battery Battery Sticker Care must be taken not to catch Connect the Interface Cable to CN501 on the Main PC BoardSet the date and time using the following procedure System Setting Date and Time SettingWith the Feed or Restart key Expansion I/O Board B-SA704-IO-QM-R SMW-3x6 Screw Blind Plate Attach the Side Panel, removed in , back to the printer Connect the Interface Cable to CN4 on the Main PC BoardApplicable Model Rfid Module B-SA704-RFID-U2-EU-RPacking List Outline of the introduction of an Rfid Kit Side Panel Hook Upper Sensor Ass’y Upper Sensor Lever Connect the Interface Cable to CN6 on the Main PC Board. CN6 Attach the Cable Clamp to the position shown below Connect the Interface Cable to the Rfid Module Re-place the Media Sensor Block When Short-Pitch Rfid Tags 20mm are usedMedia Guide Module None Rfid Module SettingsEPC C1 Gen2 Cycle TIM ADJ Retry +00 Value AGC Threshold Setting From the previous 3132333435363738 39304142 0A 0500-02 08 5 D Service No. LabelIdentification of The Rfid Module B-SA704-RFID-U2-EU-R Serial No. Label