8. RFID Module: B-SA704-RFID-U2-EU-R

Continued from the

previous page.

<10>RFID

TAG NONE

[PAUSE]

<10>RFID

ERR CHK OFF

[PAUSE]

<10>RFID

ISSUE RETRY 3

[PAUSE]

<10>RFID

R CYCLE CNT 5

RFID tag type setting menu is displayed.

Choose “EPC C1 Gen2: 24” with the [FEED] or [RESTART] key.

 

 

 

 

 

[RESTART]

NONE: When a tag type is not selected.

 

 

 

 

EPC C1 Gen2: 24

 

[FEED]

 

Press the [PAUSE] key.

RFID error tag detection menu is displayed. Choose whether to perform an error tag detection or not with the [FEED] or [RESTART] key.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[RESTART]

OFF: An error tag detection is not performed. (Usually,

 

 

 

 

 

 

 

 

choose OFF.)

 

 

 

 

[FEED]

 

 

 

 

 

 

 

ON: An error tag detection is performed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON:

A tag is read before writing data on it, and data is written on the tag only when the

 

header data is “A5A5”.

 

OFF:

Though a tag is read before writing data on it, data write is always performed

 

whatever data has been set as the header data.

Press the [PAUSE] key.

Max. number of issue retries setting menu is displayed. Set the maximum number of retries to issue an RFID tag.

When issuing an RFID tag failed, the printer prints the error pattern, and retries to issue the tag for up to specified number of times. If the printer does not succeed even after having retried for the max. times, the printer stops, resulting in an error.

Choose the max. number of retries with the [FEED] or [RESTART] key.

 

 

 

 

 

255

 

 

 

 

 

 

[RESTART]

 

 

 

 

 

 

 

 

 

 

3 (Default)

 

 

[FEED]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

Press the [PAUSE] key.

Max. number of read retries setting menu is displayed. Set the maximum number of retries to read an RFID tag.

The printer retries to read the data in an RFID tag for up to specified number of times. If the timeout period expired before the max. number retries have been done, the printer stops the retries at the time.

[PAUSE]

Continued to the next page.

Whenever the printer writes data onto an RFID tag, the tag is read first. The max. number of retries set by this parameter becomes also effective in this pre-read.

Choose the max. number of retries with the [FEED] or [RESTART] key.

255

[RESTART]

5 (Default)

 

 

 

 

[FEED]

 

 

 

 

 

 

 

0

 

 

 

Press the [PAUSE] key.

8- 12

Image 52
Contents SA4T Series Table of Contents Cutter Module SA204-QM / B-SA204-QM-R100 Front Cover Hinge Screw System Mode Manual Close the Cutter Module CoverOpen the Front Cover, and remove the Connector Cover SA204P-QM-RSet Screw Cutter Unit Connector 3x6 Screw Ground Wire Cutter Harness Strip Module Guide Roller 1 pc Installation Manual 1 copySA904-H-QM-R 100 Front Cover HingeScrew Close the Strip Unit Attaching the Cutter System Mode Settings for Stripping PET Labels 3ADJUST SET Feed ADJ 2PARAMETER SET Back Speed STD SA904P-H-QM-R SMW-3x6 Screw 4 pcs100 Front Cover HingeStopper Close the Strip Unit Opening Strip Unit Cutter Wireless LAN Module B-SA704-WLAN-QM FCC/IC Sticker 1 pcRemove the two SMW-3x6 screws from the back of the printer SA4TM SA4TPRemove the two SMW-3x6 screws to detach the Blind Plate Remove the SMW-3x8 screw to detach the Cable ClampCopper foil Re-attach the Side Panel to the printer Country Code SMW-3x6 Screw 3 pcs Serial Interface Board B-SA704-RS-QM-RRemove the two screws from the back of the printer Remove the two screws to detach the Blind Plate Fit the Locking Support into the Main PC Board SMW-3x6 Locking Support Packing List Dpi Print Head Kit B-SA704-TPH3-QM-RNever loosen or remove these screws Installation Procedure Disconnect the Print Head Cable from the Print HeadReal Time Clock B-SA704-RTC-QM-R Battery Socket Lithium Battery Battery Sticker Connect the Interface Cable to CN501 on the Main PC Board Care must be taken not to catchSystem Setting Date and Time Setting Set the date and time using the following procedureWith the Feed or Restart key Expansion I/O Board B-SA704-IO-QM-R SMW-3x6 Screw Blind Plate Connect the Interface Cable to CN4 on the Main PC Board Attach the Side Panel, removed in , back to the printerRfid Module B-SA704-RFID-U2-EU-R Applicable ModelPacking List Outline of the introduction of an Rfid Kit Side Panel Hook Upper Sensor Ass’y Upper Sensor Lever Connect the Interface Cable to CN6 on the Main PC Board. CN6 Attach the Cable Clamp to the position shown below Connect the Interface Cable to the Rfid Module When Short-Pitch Rfid Tags 20mm are used Re-place the Media Sensor BlockMedia Guide Rfid Module Settings Module NoneEPC C1 Gen2 Cycle TIM ADJ Retry +00 Value AGC Threshold Setting From the previous 3132333435363738 39304142 0A Service No. Label Identification of The Rfid Module B-SA704-RFID-U2-EU-RSerial No. Label 0500-02 08 5 D