Toshiba B-SA4T installation manual AGC Threshold Setting

Page 56

INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT

EO15-33001A

(Revision Date: Feb. 25, 2008)

8. RFID Module: B-SA704-RFID-U2-EU-R

AGC Threshold Setting

The B-SA704-RFID-U2-EU-R chooses a tag to write data on according to a radio intensity of RFID tags (AGC value).

An AGC threshold value has been set to 11 (0Bh) as factory default, but it may be necessary to change this value according to the tag type to be used.

When the factory default threshold value is not proper for the tag type used, follow the procedure below to configure the following settings.

As the changes are stored in the internal memory, they are retained after the printer power is turned off and on again. When the tag type is changed or data write cannot be operated properly, perform the setting again.

Step 1. Load an RFID tag embedded media in the printer.

Step 2. Follow the procedure below to measure the radio intensity of the tags.

1)Place the media so that an RFID tag (IC chip) is positioned above the Antenna, and close the Top

Cover.

Printer

Media

Print Head

Platen

Antenna

Antenna Cable

RFID Module

RFID

Tag

Note: If an RFID tag is not positioned above the Antenna while the Print Head is at a print start position, use @003 command to adjust the media position so that an RFID tag is positioned above the Antenna. For detail of the command, refer to the External Equipment Interface Specification (Printer Command Manual).

2Start the printer in the system mode and perform a read test to measure the AGC value.

Example

Turn the printer on while holding down the [FEED] and [PAUSE] keys at the same time.

<1>DIAG. V1.6

[RESTART]

When “<1>DIAG. V1.6” is displayed, press the [RESTART] key.

<10>RFID

[PAUSE]

<10>RFID

READ TEST OFF

[FEED] or [RESTAT]

When “<10>RFID” is displayed, press the [PAUSE] key.

Read test menu is displayed.

Press the [FEED] or [RESTAT] key to choose “READ TEST ON”.

<10>RFID

READ TEST ON

[PAUSE]

<10>RFID READING•••.

Press the [PAUSE] key to implement a read test.

Continued to the next page

8- 16

Image 56
Contents SA4T Series Table of Contents Cutter Module SA204-QM / B-SA204-QM-R100 Front Cover Hinge Screw System Mode Manual Close the Cutter Module CoverOpen the Front Cover, and remove the Connector Cover SA204P-QM-RSet Screw Cutter Unit Connector 3x6 Screw Ground Wire Cutter Harness SA904-H-QM-R Guide Roller 1 pc Installation Manual 1 copyStrip Module 100 Front Cover HingeScrew Close the Strip Unit Attaching the Cutter System Mode Settings for Stripping PET Labels 3ADJUST SET Feed ADJ 2PARAMETER SET Back Speed STD SA904P-H-QM-R SMW-3x6 Screw 4 pcs100 Front Cover HingeStopper Close the Strip Unit Opening Strip Unit Cutter Wireless LAN Module B-SA704-WLAN-QM FCC/IC Sticker 1 pcRemove the two SMW-3x6 screws from the back of the printer SA4TM SA4TPRemove the two SMW-3x6 screws to detach the Blind Plate Remove the SMW-3x8 screw to detach the Cable ClampCopper foil Re-attach the Side Panel to the printer Country Code Remove the two screws from the back of the printer Serial Interface Board B-SA704-RS-QM-RSMW-3x6 Screw 3 pcs Remove the two screws to detach the Blind Plate Fit the Locking Support into the Main PC Board SMW-3x6 Locking Support Never loosen or remove these screws Dpi Print Head Kit B-SA704-TPH3-QM-RPacking List Installation Procedure Disconnect the Print Head Cable from the Print HeadReal Time Clock B-SA704-RTC-QM-R Battery Socket Lithium Battery Battery Sticker Connect the Interface Cable to CN501 on the Main PC Board Care must be taken not to catchSystem Setting Date and Time Setting Set the date and time using the following procedureWith the Feed or Restart key Expansion I/O Board B-SA704-IO-QM-R SMW-3x6 Screw Blind Plate Connect the Interface Cable to CN4 on the Main PC Board Attach the Side Panel, removed in , back to the printerRfid Module B-SA704-RFID-U2-EU-R Applicable ModelPacking List Outline of the introduction of an Rfid Kit Side Panel Hook Upper Sensor Ass’y Upper Sensor Lever Connect the Interface Cable to CN6 on the Main PC Board. CN6 Attach the Cable Clamp to the position shown below Connect the Interface Cable to the Rfid Module When Short-Pitch Rfid Tags 20mm are used Re-place the Media Sensor BlockMedia Guide Rfid Module Settings Module NoneEPC C1 Gen2 Cycle TIM ADJ Retry +00 Value AGC Threshold Setting From the previous 3132333435363738 39304142 0A Service No. Label Identification of The Rfid Module B-SA704-RFID-U2-EU-RSerial No. Label 0500-02 08 5 D