Siemens MCC-3298 user manual Samms-Lvx

Page 16

3 Operating the SAMMS-LV Device

Figure 3.3 Ladder symbols used with the SAMMS-LV device (sheet 2)

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

STOP or OFF

 

 

 

 

 

 

 

 

 

PB6

AUTO or

SAMMS-LVX

 

 

 

L1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Current

 

 

 

 

VARIABLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unbalance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED

VARIABLE Flashing

 

 

 

 

 

 

 

 

PB5

 

Current

 

 

 

40%

 

 

 

 

 

 

 

 

 

OFF or

Unbalance

 

 

 

 

 

 

L2

 

Impending

 

 

 

 

Impending

 

> 110%

 

> 100%

 

 

 

 

 

 

 

VARIABLE

Trip

 

 

 

< 110%

 

 

 

 

Trip

 

 

 

 

 

Overload

VARIABLE

 

 

 

 

 

 

 

 

 

 

 

Trip

 

 

 

 

 

 

 

 

 

PB4

HAND or

 

 

 

 

 

 

 

L3

 

 

 

 

 

 

Incomplete

 

Trip

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Overload

 

 

 

 

VARIABLE

Sequence

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

External

 

Trip: Loss

 

Alarm: Loss

 

 

Trip

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Trip Alarm

 

of Load,or

 

of Load or

 

 

 

 

 

 

 

 

PB3

 

 

 

Jam

 

Prcs Current

 

 

 

 

 

 

 

 

VARIABLE

 

 

 

 

 

 

 

 

 

 

 

 

CPU

 

Trip: CPU

 

 

 

 

CPU

 

Incomplete

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Failure or

 

 

 

 

Fault

 

Sequence

 

 

 

 

 

Fault

 

 

 

 

 

 

 

 

 

 

 

 

 

Low Voltage

 

 

 

 

 

 

 

 

 

 

 

 

Ground

 

Trip

 

Alarm

 

 

 

 

 

 

 

 

 

PB2

VARIABLE

Fault

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ground

 

External

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fault

 

Trip/Alarm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reset/Test

 

 

 

PB1

STOP or OFF

 

 

 

 

 

 

 

Ready

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 3.4 Assignment of pushbuttons and light bars 14

Image 16
Contents SAMMS-LV Qualified Person Contents Field Service Operation Signal WordsQualified Person About this Manual SAMMS-LV Device Models Advanced Protection for Low-Voltage MotorsOverload Protection Using the Standardized Control PanelProgramming Control Circuits Change settings requires password Yes Remote inputs SAMMS-LV ModelOutputs One Light barsInstalling the SAMMS-LV Device Full voltage non-reversing connection diagram Grounding the Device SAMMS-LV device communications connections Password Protection Using the Reset/Test Push ButtonPerforming a Lamp Test Performing an Overload Relay TestOutput Devices Input DevicesLadder Diagrams Library of Standard Ladder Diagrams Custom Ladder DiagramsSAMMS-LVX Standard control circuits RVA Ridethrough Upon Loss of Power SAMMS-LVX Only Motor Ambient TemperatureIncomplete Sequence Intelligent Reduced-Voltage Starting SAMMS-LVX OnlyODP motor thermal signature Operating the SAMMS-LV Operating the SAMMS-LV Device 10 Motor protection graph Ultimate Trip Level and Service Factor Phase UnbalanceDual Overload Protection SAMMS-LVX Only Jam Protection SAMMS-LVX OnlyGround Fault Detection Stator ProtectionRepetitive Starts Start InhibitAutoreset After a Trip SAMMS-LVX Only Using the Hand Held Communicator HHCSize Pickup Current Default Pickup Range Emergency Restarting5A CT primary current if used Full load current for OLR No Function NumberJam pickup current F24 Loss of load protection or warning Using the Enter Key Function KeyList Key UP and Down KeysExternal trips Enable/disable phase unbalance CapabilitySelect ground fault pick-up current Value 2A-5A Step Size Second Default ValueMeans warning Iflc is the value of Iflc forUsing the SAMMS-LV Device Func Tions Program Mode/PasswordsSelect jam pickup current 120-400% I FLC F24 Loss of Load 200% 50% 480013 Entering and changing passwords F0 Ambient Temperature SAMMS-LV FunctionsF1 Control Circuit Number and Incomplete Se- quence Status F2 Size for Overload Relay #1Overload Setting Step Default Relay Size Range 24.0A 36A F4 Full-Load Current for Overload Relay #145A 90AF6 Service Factor F8 Autoreset SAMMS-LVX OnlyF9 Phase Unbalance Protection F7 Overload Trip ClassF10 Display Time to Restart F12 Ground Fault Protection or WarningF11 Emergency Restarting F12A Ground Fault Pickup Current F13 Set Programmable Timer #1F14 Set Programmable Timer #2 F15 Display CurrentF21 Reset Motor Data F17 Current UnbalanceF18 Display Total Elapsed Run Time of the Motor F19 Number of Motor StartsF25 Percentage of Motor Winding Temperature F23A Jam Pickup Current SAMMS-LVX OnlyF24 Loss of Load Protection or Warning SAMMS-LVX Only F24A Loss of Load Pickup Current SAMMS-LVX OnlyF27 Address Troubleshooting Error Condition Troubleshooting Guide Error Condition Appendix a Technical Specifications Overload Specifications Statistical Data Dimensions Catalog Number SAM4 Switch # Function Position Samms Sensor, sizes 1C, 2A, 2B Page Siemens Energy Automation, Inc