Siemens MCC-3298 SAMMS-LV Model, Change settings requires password Yes Remote inputs, Outputs One

Page 8

1 Introduction

SAMMS-LV Model

SAMMS-LVE

SAMMS-LVX

 

 

 

Application

 

 

Across-the-line, non reversing

X

X

Across-the-line, reversing

 

X

Two-speed, one winding, constant or

 

X

variable torque

 

 

Two-speed, one winding, constant

 

X

horsepower

 

 

Two-speed, two winding

 

X

Reduced voltage, autotransformer

 

X

Reduced voltage, Y-D, open transition

 

X

Reduced voltage, Y-D, closed transition

 

X

Part winding

 

X

Wye-delta

 

X

Full voltage, part winding

 

X

 

 

 

Functions available (see table 3.7)

F0-F21 plus F25-F27 (except no

F0-F27

 

F3, F5, or F8)

 

 

 

 

Ridethrough upon loss of power

No

Yes

 

 

 

Ground fault protection/alarm

Yes

Yes

 

 

 

Programmable alarm contact

No

Yes

 

 

 

Control circuits

Seven (preloaded), selectable with

Any downloadable control circuit

 

HHC. May download any custom

 

 

across-the-line control circuit

 

 

 

 

Change settings requires password

Yes

Yes

 

 

 

Remote inputs

Two

Four

 

 

 

Outputs

One

Three

 

 

 

Light bars

Two

Three

 

 

 

Table 1.2 SAMMS-LV models

6

Image 8
Contents SAMMS-LV Qualified Person Contents Qualified Person Signal WordsField Service Operation About this Manual SAMMS-LV Device Models Advanced Protection for Low-Voltage MotorsProgramming Control Circuits Using the Standardized Control PanelOverload Protection Change settings requires password Yes Remote inputs SAMMS-LV ModelOutputs One Light barsInstalling the SAMMS-LV Device Full voltage non-reversing connection diagram Grounding the Device SAMMS-LV device communications connections Password Protection Using the Reset/Test Push ButtonPerforming a Lamp Test Performing an Overload Relay TestOutput Devices Input DevicesLadder Diagrams Library of Standard Ladder Diagrams Custom Ladder DiagramsSAMMS-LVX Standard control circuits RVA Ridethrough Upon Loss of Power SAMMS-LVX Only Motor Ambient TemperatureIncomplete Sequence Intelligent Reduced-Voltage Starting SAMMS-LVX OnlyODP motor thermal signature Operating the SAMMS-LV Operating the SAMMS-LV Device 10 Motor protection graph Ultimate Trip Level and Service Factor Phase UnbalanceDual Overload Protection SAMMS-LVX Only Jam Protection SAMMS-LVX OnlyGround Fault Detection Stator ProtectionRepetitive Starts Start InhibitAutoreset After a Trip SAMMS-LVX Only Using the Hand Held Communicator HHCSize Pickup Current Default Pickup Range Emergency RestartingJam pickup current F24 Loss of load protection or warning Function Number5A CT primary current if used Full load current for OLR No Using the Enter Key Function KeyList Key UP and Down KeysExternal trips Enable/disable phase unbalance CapabilitySelect ground fault pick-up current Value 2A-5A Step Size Second Default ValueMeans warning Iflc is the value of Iflc forUsing the SAMMS-LV Device Func Tions Program Mode/PasswordsSelect jam pickup current 120-400% I FLC F24 Loss of Load 200% 50% 480013 Entering and changing passwords F0 Ambient Temperature SAMMS-LV FunctionsF1 Control Circuit Number and Incomplete Se- quence Status F2 Size for Overload Relay #1Overload Setting Step Default Relay Size Range 24.0A 36A F4 Full-Load Current for Overload Relay #145A 90AF6 Service Factor F8 Autoreset SAMMS-LVX OnlyF9 Phase Unbalance Protection F7 Overload Trip ClassF11 Emergency Restarting F12 Ground Fault Protection or WarningF10 Display Time to Restart F12A Ground Fault Pickup Current F13 Set Programmable Timer #1F14 Set Programmable Timer #2 F15 Display CurrentF21 Reset Motor Data F17 Current UnbalanceF18 Display Total Elapsed Run Time of the Motor F19 Number of Motor StartsF25 Percentage of Motor Winding Temperature F23A Jam Pickup Current SAMMS-LVX OnlyF24 Loss of Load Protection or Warning SAMMS-LVX Only F24A Loss of Load Pickup Current SAMMS-LVX OnlyF27 Address Troubleshooting Error Condition Troubleshooting Guide Error Condition Appendix a Technical Specifications Overload Specifications Statistical Data Dimensions Catalog Number SAM4 Switch # Function Position Samms Sensor, sizes 1C, 2A, 2B Page Siemens Energy Automation, Inc