Page 17

3 Operating the SAMMS-LV Device

 

 

 

 

 

 

Input Assignments

 

 

 

 

 

 

 

 

 

 

 

 

 

Starter

Program

Control Type

PB1

PB2

PB3

PB4

PB5

PB6

 

Type

Block

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Preloaded in

FVNR

PB10

LOCAL, 2-WIRE

OFF

ON

 

 

 

 

SAMMS-LVE,

 

 

 

 

 

 

 

 

 

 

PB11

LOCAL, 3-WIRE

STOP

START

 

 

 

 

can be

 

 

 

 

 

 

 

 

 

 

 

 

 

 

downloaded in

 

PB12

LOCAL, 3-WIRE, REMOTE 2-WIRE

STOP

START

 

HAND

OFF

AUTO

SAMMS-LVX

 

PB13

LOCAL/REMOTE 2-WIRE

STOP

 

 

HAND

OFF

AUTO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PB14

LOCAL/REMOTE 3-WIRE

STOP

START

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PB15

REMOTE, 2-WIRE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PB16

REMOTE, 3-WIRE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Available with

FVR

PB17

LOCAL, 2-WIRE

OFF

FWD

REV

 

 

 

SAMMS-LVX

 

 

 

 

 

 

 

 

 

 

PB18

LOCAL, 3-WIRE

STOP

FWD

REV

 

 

 

only

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PB19

LOCAL, 3-WIRE, REMOTE 2-WIRE

STOP

FWD

REV

HAND

OFF

AUTO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PB20

LOCAL/REMOTE 2-WIRE

STOP

FWD

REV

HAND

OFF

AUTO

 

 

 

 

 

 

 

 

 

 

 

 

PB21

LOCAL/REMOTE 3-WIRE

STOP

FWD

REV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PB22

REMOTE, 2-WIRE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PB23

REMOTE, 3-WIRE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PB24

LOCAL/REMOTE 3-WIRE ELECTRICALLY

STOP

FWD

REV

 

 

 

 

 

 

INTERLOCKED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2SPD,2W

PB25

LOCAL, 2-WIRE

OFF

LOW

HIGH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PB26

LOCAL, 3-WIRE

STOP

LOW

HIGH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PB27

LOCAL, 3-WIRE, REMOTE 2-WIRE

STOP

LOW

HIGH

HAND

OFF

AUTO

 

 

 

 

 

 

 

 

 

 

 

 

PB28

LOCAL/REMOTE 2-WIRE

STOP

LOW

HIGH

HAND

OFF

AUTO

 

 

 

 

 

 

 

 

 

 

 

 

PB29

LOCAL/REMOTE 3-WIRE

STOP

LOW

HIGH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PB30

REMOTE, 2-WIRE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PB31

REMOTE, 3-WIRE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2SPD, 1W,

PB32

LOCAL, 2-WIRE

OFF

LOW

HIGH

 

 

 

 

CT OR VT

 

 

 

 

 

 

 

 

 

PB33

LOCAL, 3-WIRE

STOP

LOW

HIGH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PB34

LOCAL, 3-WIRE, REMOTE 2-WIRE

STOP

LOW

HIGH

HAND

OFF

AUTO

 

 

 

 

 

 

 

 

 

 

 

 

PB35

LOCAL/REMOTE 2-WIRE

STOP

LOW

HIGH

HAND

OFF

AUTO

 

 

 

 

 

 

 

 

 

 

 

 

PB36

LOCAL/REMOTE 3-WIRE

STOP

LOW

HIGH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PB37

REMOTE, 2-WIRE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PB38

REMOTE, 3-WIRE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2SPD, 1W,

PB39

LOCAL, 2-WIRE

OFF

LOW

HIGH

 

 

 

 

CH

 

 

 

 

 

 

 

 

 

PB40

LOCAL, 3-WIRE

STOP

LOW

HIGH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PB41

LOCAL, 3-WIRE, REMOTE 2-WIRE

STOP

LOW

HIGH

HAND

OFF

AUTO

 

 

 

 

 

 

 

 

 

 

 

 

PB42

LOCAL/REMOTE 2-WIRE

STOP

LOW

HIGH

HAND

OFF

AUTO

 

 

 

 

 

 

 

 

 

 

 

 

PB43

LOCAL/REMOTE 3-WIRE

STOP

LOW

HIGH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PB44

REMOTE, 2-WIRE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PB45

REMOTE, 3-WIRE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 3.3 Standard control circuits

15

Image 17
Contents SAMMS-LV Qualified Person Contents Qualified Person Signal WordsField Service Operation About this Manual Advanced Protection for Low-Voltage Motors SAMMS-LV Device ModelsProgramming Control Circuits Using the Standardized Control PanelOverload Protection SAMMS-LV Model Change settings requires password Yes Remote inputsOutputs One Light barsInstalling the SAMMS-LV Device Full voltage non-reversing connection diagram Grounding the Device SAMMS-LV device communications connections Using the Reset/Test Push Button Password ProtectionPerforming a Lamp Test Performing an Overload Relay Test Input Devices Output DevicesCustom Ladder Diagrams Ladder Diagrams Library of Standard Ladder DiagramsSAMMS-LVX Standard control circuits RVA Motor Ambient Temperature Ridethrough Upon Loss of Power SAMMS-LVX OnlyIncomplete Sequence Intelligent Reduced-Voltage Starting SAMMS-LVX OnlyODP motor thermal signature Operating the SAMMS-LV Operating the SAMMS-LV Device 10 Motor protection graph Phase Unbalance Ultimate Trip Level and Service FactorDual Overload Protection SAMMS-LVX Only Jam Protection SAMMS-LVX OnlyStator Protection Ground Fault DetectionRepetitive Starts Start InhibitUsing the Hand Held Communicator HHC Autoreset After a Trip SAMMS-LVX OnlySize Pickup Current Default Pickup Range Emergency RestartingJam pickup current F24 Loss of load protection or warning Function Number5A CT primary current if used Full load current for OLR No Function Key Using the Enter KeyList Key UP and Down KeysCapability External trips Enable/disable phase unbalanceStep Size Second Default Value Select ground fault pick-up current Value 2A-5AMeans warning Iflc is the value of Iflc forProgram Mode/Passwords Using the SAMMS-LV Device Func TionsSelect jam pickup current 120-400% I FLC F24 Loss of Load 200% 50% 480013 Entering and changing passwords SAMMS-LV Functions F0 Ambient TemperatureF1 Control Circuit Number and Incomplete Se- quence Status F2 Size for Overload Relay #1F4 Full-Load Current for Overload Relay #1 Overload Setting Step Default Relay Size Range 24.0A 36A45A 90AF8 Autoreset SAMMS-LVX Only F6 Service FactorF9 Phase Unbalance Protection F7 Overload Trip ClassF11 Emergency Restarting F12 Ground Fault Protection or WarningF10 Display Time to Restart F13 Set Programmable Timer #1 F12A Ground Fault Pickup CurrentF14 Set Programmable Timer #2 F15 Display CurrentF17 Current Unbalance F21 Reset Motor DataF18 Display Total Elapsed Run Time of the Motor F19 Number of Motor StartsF23A Jam Pickup Current SAMMS-LVX Only F25 Percentage of Motor Winding TemperatureF24 Loss of Load Protection or Warning SAMMS-LVX Only F24A Loss of Load Pickup Current SAMMS-LVX OnlyF27 Address Troubleshooting Error Condition Troubleshooting Guide Error Condition Appendix a Technical Specifications Overload Specifications Statistical Data Dimensions Catalog Number SAM4 Switch # Function Position Samms Sensor, sizes 1C, 2A, 2B Page Siemens Energy Automation, Inc