Agilent Technologies 8753ET Type-N test ports, Calibration kit 85032B Test-port cables 11857D

Page 5

Agilent 8753ES (50-ohm systems)

Type-N test ports

Configuration

 

Network analyzer

8753ES

 

Standard and Option 006

Calibration kit

85032B

Test-port cables

11857D

System dynamic range

 

30 kHz to 50 kHz

70 dB1

50 kHz to 300 kHz

90 dB1

300 kHz to 16 MHz

100 dB

16 MHz to 3 GHz

110 dB

Option 014

108 dB

3 GHz to 6 GHz

105 dB

Option 014

103 dB

Reflection uncertainty

Magnitude

Transmission uncertainty

Magnitude

Measurement Port Characteristics

Frequency Range

Corrected

30 kHz–

300 kHz–

1.3 GHz–

3

GHz–

 

300 kHz2

1.3 GHz

3 GHz

6

GHz

 

 

 

 

 

Directivity

50 dB

50 dB

47 dB

40 dB

 

 

 

 

 

Source match

49 dB

42 dB

36 dB

31 dB

 

 

 

 

 

Load match

50 dB

50 dB

47 dB

40 dB

 

 

 

 

 

Reflection

±(0.005 dB

±(0.009 dB

±(0.019 dB

±(0.070 dB

tracking

+0.02 dB/°C)

+0.01 dB/°C)

+0.02 dB/°C)

+0.03 dB/°C)

 

 

 

 

 

Transmission

±(0.014 dB

±(0.013 dB

±(0.026 dB

±(0.065 dB

tracking

+0.02 dB/°C)

+0.01 dB/°C)

+0.02 dB/°C)

+0.03 dB/°C)

 

 

 

 

 

 

Phase

Phase

1.

Typical below 300 kHz.

5

2.

Typical performance.

Image 5
Contents 8753ET and 8753ES Network Analyzers, 30 kHz to 3 or 6 GHz Agilent 8753ET/ESTable of Contents Measurement Uncertainty Measurement Port CharacteristicsDynamic Range Agilent 8753ES 50-ohm systems ConfigurationSystem dynamic range Reflection uncertaintyCalibration kit 85032B Test-port cables 11857D Type-N test portsCalibration kit 85033D Test-port cables 11857D Calibration kit 85036B Test-port cables 11857B Agilent 8753ES 75-Ohm SystemsNetwork analyzer Calibration kit 85039B Test-port cables 11857B Type-F test portsAgilent 8753ET 50-ohm systems Measurement Port CharacteristicsPart number KHz to 16 MHz 100 dB MHz to 3 GHz 110 dBTest-Port Input Characteristics Agilent 8753ES SpecificationsTest-Port Output Characteristics7 External source mode1 CW time sweep only Phase CharacteristicsMagnitude Characteristics Test Port Input Characteristics Option Agilent 8753ES Option 011 SpecificationsTest Port Output Characteristics Channel input requirements1 Frequency offset mode3External source mode4 Agilent 8753ET Specifications Input frequency accuracy requirement2 Display resolutionReference level Range Stability2 KHz to 3 GHzGroup Delay Characteristics Agilent 8753ET/ES Supplemental CharacteristicsMeasurement Source ControlDisplay Control Data Accuracy EnhancementData Averaging Storage Trace FunctionsData Hardcopy System CapabilitiesRemote Programming Test SequencesTime-domain Option Rear-Panel Connectors General CharacteristicsFront Panel Connectors General Conditions Cabinet Dimensions 8753ET/ESOptions Agilent 85046A/B S-Parameter Test Sets Test Set Specifications for OptionAgilent 85046A/B Specifications Agilent 85047A S-Parameter Test Set SpecificationsCalibration Kits AccessoriesAgilent 11906 Family of Adapter Kits Agilent 85038 Family of Calibration KitsTest-Port Return Cables Verification Kits85024A High-Frequency Probe Ohm Accessory KitsRF Limiter Agilent 8347A RF Amplifier Weight Net 3.5 kg 7.7 lb