The 8347A RF amplifier delivers increased power across a 300 kHz to 3 GHz frequency range. The 8347A provides leveled output power without using an external coupler and detector, since these parts are built-in. The external ALC can be directly connected to the external AM input on the 8753ET/ES. This capability is espe- cially useful for achieving high dynamic range measurements at faster sweep rates.

Specifications

 

Frequency

100 kHz to 3 GHz

Gain

25 dB minimum

Output power (leveled)

+5 dBm to +20 dBm

 

(adjustable)

Maximum output power

24 dBm typical

Leveled power flatness

±1.5 dB

Impedance

50 ohms nominal

SWR

 

Input

2.2:1 max

Output

1.6:1 (ALC on)

Spectral purity

 

Harmonics

-20 dBc at dBm

Third-order intercept

+30 dBm (nominal)

Typical noise figure

 

100 MHz to 3 GHz

13.5 dB

RF connectors

Type-N female

Dimensions

102-mm H x 213-mm

 

W x 297-mm D

 

(4.0 in x 8.4 in x 11.7 in)

Weight

net 3.5 kg (7.7 lb)

MS-DOS®is a U.S. registered trademark of Microsoft Corporation. Pentium® is a U.S. registered trademark of Microsoft Corporation.

Agilent Technologies’ Test and Measurement

Support, Services, and Assistance

Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Support is available for at least five years beyond the produc- tion life of the product. Two concepts underlie Agilent’s overall support policy: “Our Promise” and “Your Advantage.”

Our Promise

“Our Promise” means your Agilent test and measurement equip- ment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifica- tions and practical recommendations from experienced test engineers. When you use Agilent equipment, we can verify that it works properly, help with product operation, and provide basic measurement assistance for the use of specified capabili- ties, at no extra cost upon request. Many self-help tools are available.

Your Advantage

“Your Advantage” means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, out- of-warranty repairs, and on-site education and training, as well as design, system integration, project management, and other professional services. Experienced Agilent engineers and tech- nicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products.

Get assistance with all your test and measurement needs at:

www.agilent.com/find/assist

Product specifications and descriptions in this document subject to change without notice.

Copyright © 1999, 2001 Agilent Technologies Printed in U.S.A. February 12, 2001 5968-5160E

Image 28 Contents
Agilent 8753ET/ES 8753ET and 8753ES Network Analyzers, 30 kHz to 3 or 6 GHzTable of Contents Dynamic Range Measurement Port CharacteristicsMeasurement Uncertainty Configuration Agilent 8753ES 50-ohm systemsSystem dynamic range Reflection uncertaintyType-N test ports Calibration kit 85032B Test-port cables 11857DCalibration kit 85033D Test-port cables 11857D Network analyzer Agilent 8753ES 75-Ohm SystemsCalibration kit 85036B Test-port cables 11857B Type-F test ports Calibration kit 85039B Test-port cables 11857BMeasurement Port Characteristics Agilent 8753ET 50-ohm systemsPart number KHz to 16 MHz 100 dB MHz to 3 GHz 110 dBTest-Port Output Characteristics7 Agilent 8753ES SpecificationsTest-Port Input Characteristics Magnitude Characteristics Phase CharacteristicsExternal source mode1 CW time sweep only Test Port Output Characteristics Agilent 8753ES Option 011 SpecificationsTest Port Input Characteristics Option External source mode4 Frequency offset mode3Channel input requirements1 Agilent 8753ET Specifications Display resolution Input frequency accuracy requirement2Reference level Range Stability2 KHz to 3 GHzAgilent 8753ET/ES Supplemental Characteristics Group Delay CharacteristicsMeasurement Source ControlData Averaging Data Accuracy EnhancementDisplay Control Trace Functions StorageData Hardcopy System CapabilitiesTime-domain Option Test SequencesRemote Programming Front Panel Connectors General CharacteristicsRear-Panel Connectors Options Cabinet Dimensions 8753ET/ESGeneral Conditions Agilent 85046A/B Specifications Test Set Specifications for OptionAgilent 85046A/B S-Parameter Test Sets Specifications Agilent 85047A S-Parameter Test SetAccessories Calibration KitsAgilent 85038 Family of Calibration Kits Agilent 11906 Family of Adapter KitsVerification Kits Test-Port Return CablesRF Limiter Ohm Accessory Kits85024A High-Frequency Probe Weight Net 3.5 kg 7.7 lb Agilent 8347A RF Amplifier