AEG Thyro-S H1 manual Tab Cyclic input and output data with Thyro-A 3A...HRL1

Page 19

Tab. 13 Cyclic input and output data with Thyro-A 3A...HRL1

Offset

Input data, actual values

Data type

Size

Unit

0

Load voltage L1

float

4

[V]

4

Load voltage L2

float

4

[V]

8

Load voltage L3

float

4

[V]

12

Load current L1

float

4

[A]

16

Load current L2

float

4

[A]

20

Load current L3

float

4

[A]

24

Mains voltage L1

integer

2

[V]

26

Mains voltage L2

integer

2

[V]

28

Mains voltage L3

integer

2

[V]

30

Switch-on time TS

integer

2

[period]

32

Switch-on angle alpha

integer

2

[0.01 °el]

34

Total setpoint

integer

2

4096=100%

36

Fault (see table 14b)

integer

2

-

38

Status (see table 14b)

integer

2

-

Offset

Output data, setpoint

Data type

Size

Unit

0

Master setpoint

integer

2

4096=100%

Tab. 14 Cyclic input and output data with Thyro-A 3A...HRLP1

Offset

Input data, actual values

Data type

Size

Unit

0

Load voltage L1

float

4

[V]

4

Load voltage L2

float

4

[V]

8

Load voltage L3

float

4

[V]

12

Load current L1

float

4

[A]

16

Load current L2

float

4

[A]

20

Load current L3

float

4

[A]

24

Power L1

float

4

[W]

28

Power L2

float

4

[W]

32

Power L3

float

4

[W]

36

Total power

float

4

[W]

40

Mains voltage L1

integer

2

[V]

42

Mains voltage L2

integer

2

[V]

44

Mains voltage L3

integer

2

[V]

46

Switch-on time TS

integer

2

[period]

48

Switch-on angle alpha

integer

2

[0.01 °el]

50

Total setpoint

integer

2

4096=100%

52

Fault (see table 14b)

integer

2

-

54

Status (see table 14b)

integer

2

-

Offset

Output data, setpoint

Data type

Size

Unit

0

Master setpoint

integer

2

4096=100%

19

Image 19
Contents Ethernet Bus Module ProfiNet Contents List of figures and tables Contact Introduction Electric current SafetyIdentification in the operating instructions General danger informationUse of the device Operator requirementsPersonnel requirements Intended useMaintenance, service, faults Prior to installation / commissioningTransport Processing the setpoint Thyro-S FunctionsProcessing the setpoint Thyro-A Freely addressable digital outputs Processing the setpoint Thyro-Step ControllerRelais Control Connecting the Ethernet bus module to the master InstallationConnecting a 24 V power supply Connecting the power controller toSetting the device name SettingsSetting the protocol Setting the number of slotsStatus LED of the Ethernet Ports Operating display of the bus moduleOperating display of the bus module Operating status of the Ethernet bus moduleInput and output data Thyro-S Start configuration parameterizationCyclical data transmission configuration OperationTab Cyclic input and output data with Thyro-S ..HRL1 Tab b Thyro-S FaultsTab Interpretation of the master setpoint with Thyro-S Tab Cyclic input and output data with Thyro-S ..H1Tab Cyclic input and output data with Thyro-A 1A...HRL1 Input and output data Thyro-ATab b Thyro-S Status Tab Cyclic input and output data with Thyro-A 1A...H1Tab Cyclic input and output data with Thyro-A 2A...H1 Tab Cyclic input and output data with Thyro-A 1A...HRLP1Tab Cyclic input and output data with Thyro-A 2A...HRL1 Tab Cyclic input and output data with Thyro-A 3A...H1 Tab Cyclic input and output data with Thyro-A 2A...HRLP1Tab Cyclic input and output data with Thyro-A 3A...HRLP1 Tab Cyclic input and output data with Thyro-A 3A...HRL1Tab b Thyro-A Status Tab a Thyro-A FaultTab Cyclic input and output data with Thyro-A 1A...C02 Tab Cyclic input and output data with Thyro-A 1A...C01Tab Cyclic input and output data with Thyro-A 1A...C03 Tab Supported operating modes Tab Cyclic input and output data with Thyro-A 1A...C05Tab Cyclic input and output data with Thyro-A 1A...C07 Supported operating modes TPM TSC TMUTab Cyclic input and output data TPM automatic mode Input and output data Thyro-Power ManagerTab Cyclic input and output data TPM manual mode Input and output data Thyro Input/Output Unit Tab Cyclic input and output data TSC modeTab Cyclic input and output data TIO mode Input and output data Thyro-Step ControllerTab b Status TPM, TSC, TIO, TMU Tab Cyclic input and output data TMU modeTab b Fault TPM, TSC, TIO, TMU Input and output data Thyro-Measurement UnitRead data record Rdrec Acyclic data transmission parameterizationWrite data record Wrrec External connections Power supplyOperating elements and terminal blocks System interface InterfacesEthernet interfaces Connection diagram Thyro-A Connection diagrams Thyro-AConnection diagram Thyro-S Connection diagrams Thyro-SConnection diagram TSC Connection diagrams TSCSpecific notes Technical DataInstallation ServiceAccessories and options Dimension drawingsApprovals and conformity Detail Controller parameter Appendix aHRL1 Hrlp SST RLP1 U16 R309 Index R309 DAC1OF Page Type value U mains U16 …260 Measuring and cycle time …1500