AEG Thyro-S H1 manual Tab Cyclic input and output data with Thyro-A 1A...C05

Page 22

Tab. 18 Cyclic input and output data with Thyro-A 1A...C05

Offset

Input data, actual values

Data type

Size

Unit

0

Load voltage phase 1

float

4

[V]

4

Load current phase 1

float

4

[A]

8

Load current phase 2

float

4

[A]

12

Total load current

float

4

[A]

16

Power phase 1

float

4

[W]

20

Power phase 2

float

4

[W]

24

Total power

float

4

[W]

28

Mains voltage L1

integer

2

[V]

30

Switch-on angle alpha phase 1

integer

2

[0.01 °el]

32

Total setpoint

integer

2

4096=100%

34

Fault (see table 14b)

integer

2

-

36

Status (see table 14b)

integer

2

-

Offset

Output data, setpoint

Data type

Size

Unit

0

Master setpoint

integer

2

4096=100%

Tab. 19 Cyclic input and output data with Thyro-A 1A...C07

Offset

Input data, actual values

Data type

Size

Unit

0

Load voltage L1

float

4

[V]

4

Load current L1

float

4

[A]

8

Power L1

float

4

[W]

12

Mains voltage L1

integer

2

[V]

14

Load temperature

integer

2

[°C]

16

Switch-on angle alpha

integer

2

[0.01 °el]

18

Total setpoint

integer

2

4096=100%

20

Fault (see table 14b)

integer

2

-

22

Status (see table 14b)

integer

2

-

Offset

Output data, setpoint

Data type

Size

Unit

0

Master setpoint

integer

2

4096=100%

Supported operating modes TPM; TSC; TMU

With the Thyro-Power Manager, Thyro-Step Controller and Thyro-Measurement Unit the input and output data are depend on the operating mode. The following table shows which operating mode the devices support.

Tab. 20 Supported operating modes

 

TPM

 

TSC

TIO

TMU

 

automatic

manual

 

 

 

Thyro-Power Manager

X

X

X

X

X

Thyro-Step Controller

-

-

X

X

X

Thyro-Measurement Unit

-

-

-

X

X

22

Image 22
Contents Ethernet Bus Module ProfiNet Contents List of figures and tables Contact Introduction General danger information SafetyIdentification in the operating instructions Electric currentIntended use Operator requirementsPersonnel requirements Use of the deviceMaintenance, service, faults Prior to installation / commissioningTransport Processing the setpoint Thyro-S FunctionsProcessing the setpoint Thyro-A Freely addressable digital outputs Processing the setpoint Thyro-Step ControllerRelais Control Connecting the power controller to InstallationConnecting a 24 V power supply Connecting the Ethernet bus module to the masterSetting the number of slots SettingsSetting the protocol Setting the device nameOperating status of the Ethernet bus module Operating display of the bus moduleOperating display of the bus module Status LED of the Ethernet PortsOperation Start configuration parameterizationCyclical data transmission configuration Input and output data Thyro-STab Cyclic input and output data with Thyro-S ..H1 Tab b Thyro-S FaultsTab Interpretation of the master setpoint with Thyro-S Tab Cyclic input and output data with Thyro-S ..HRL1Tab Cyclic input and output data with Thyro-A 1A...H1 Input and output data Thyro-ATab b Thyro-S Status Tab Cyclic input and output data with Thyro-A 1A...HRL1Tab Cyclic input and output data with Thyro-A 2A...H1 Tab Cyclic input and output data with Thyro-A 1A...HRLP1Tab Cyclic input and output data with Thyro-A 2A...HRL1 Tab Cyclic input and output data with Thyro-A 2A...HRLP1 Tab Cyclic input and output data with Thyro-A 3A...H1Tab Cyclic input and output data with Thyro-A 3A...HRL1 Tab Cyclic input and output data with Thyro-A 3A...HRLP1Tab a Thyro-A Fault Tab b Thyro-A StatusTab Cyclic input and output data with Thyro-A 1A...C02 Tab Cyclic input and output data with Thyro-A 1A...C01Tab Cyclic input and output data with Thyro-A 1A...C03 Supported operating modes TPM TSC TMU Tab Cyclic input and output data with Thyro-A 1A...C05Tab Cyclic input and output data with Thyro-A 1A...C07 Tab Supported operating modesTab Cyclic input and output data TPM automatic mode Input and output data Thyro-Power ManagerTab Cyclic input and output data TPM manual mode Input and output data Thyro-Step Controller Tab Cyclic input and output data TSC modeTab Cyclic input and output data TIO mode Input and output data Thyro Input/Output UnitInput and output data Thyro-Measurement Unit Tab Cyclic input and output data TMU modeTab b Fault TPM, TSC, TIO, TMU Tab b Status TPM, TSC, TIO, TMURead data record Rdrec Acyclic data transmission parameterizationWrite data record Wrrec Power supply External connectionsOperating elements and terminal blocks System interface InterfacesEthernet interfaces Connection diagrams Thyro-A Connection diagram Thyro-AConnection diagrams Thyro-S Connection diagram Thyro-SConnection diagrams TSC Connection diagram TSCService Technical DataInstallation Specific notesAccessories and options Dimension drawingsApprovals and conformity Detail Appendix a Controller parameterHRL1 Hrlp SST RLP1 U16 R309 Index R309 DAC1OF Page Type value U mains U16 …260 Measuring and cycle time …1500