AEG Thyro-S H1 Operator requirements, Personnel requirements, Intended use, Use of the device

Page 7

NOTE

Communication errors

To avoid communication errors please note the following points:

>Use shielded cables.

>Undertake grounding of the bus module (X1.7 to X8.7). Do not ground additionally at the power controller.

2.3Operator requirements

The operator must ensure the following:

-The safety regulations of the operating instructions are observed.

-The accident prevention regulations valid in the respective country of use and the general safety regulations are observed.

-All safety devices (covers, warning signs etc.) are present, in perfect condition and are used correctly.

-The national and regional safety regulations are observed.

-The personnel has access to the operating instructions and safety regulations at all times.

-The operating conditions and restrictions resulting from the technical data are observed.

-Should abnormal voltages, noises, increased temperatures, vibration or similar occur, the device is immediately put out of operation and the maintenance personnel is informed

2.4Personnel requirements

Only qualified electro-technical personnel who are familiar with the pertinent safety and installation regu- lations may perform the following:

-transport

-installation

-connection

-commissioning

-maintenance

-testing

-operation

These operating instructions must be read carefully by all persons working with or on the equipment prior to installation and initial start-up

2.5 Intended use

The device may only be used for the purpose for which it was intended, as persons may otherwise be exposed to dangers (e.g. electric shock, burns) and plants also (e. g. overload). The user must therefore observe the following points:

-It is not permitted to make any unauthorized modifications to the unit or to use any spare parts or replacement parts not approved by AEG PS, or to use the unit for any other purpose.

-The warranty obligations of the manufacturer are only applicable if these operating instructions are observed and complied with.

-The device is a component that cannot function alone.

-Project planning must account for the proper use of the device.

2.6Use of the device

2.6.1Operation

-Only switch on the mains voltage at the device when there is no danger to persons, system or load.

-Protect the device against dust and damp.

-Ensure that the ventilation openings are not blocked.

7

Image 7
Contents Ethernet Bus Module ProfiNet Contents List of figures and tables Contact Introduction Electric current SafetyIdentification in the operating instructions General danger informationUse of the device Operator requirementsPersonnel requirements Intended useMaintenance, service, faults Prior to installation / commissioningTransport Processing the setpoint Thyro-S FunctionsProcessing the setpoint Thyro-A Freely addressable digital outputs Processing the setpoint Thyro-Step ControllerRelais Control Connecting the Ethernet bus module to the master InstallationConnecting a 24 V power supply Connecting the power controller toSetting the device name SettingsSetting the protocol Setting the number of slotsStatus LED of the Ethernet Ports Operating display of the bus moduleOperating display of the bus module Operating status of the Ethernet bus moduleInput and output data Thyro-S Start configuration parameterizationCyclical data transmission configuration OperationTab Cyclic input and output data with Thyro-S ..HRL1 Tab b Thyro-S FaultsTab Interpretation of the master setpoint with Thyro-S Tab Cyclic input and output data with Thyro-S ..H1Tab Cyclic input and output data with Thyro-A 1A...HRL1 Input and output data Thyro-ATab b Thyro-S Status Tab Cyclic input and output data with Thyro-A 1A...H1Tab Cyclic input and output data with Thyro-A 2A...H1 Tab Cyclic input and output data with Thyro-A 1A...HRLP1Tab Cyclic input and output data with Thyro-A 2A...HRL1 Tab Cyclic input and output data with Thyro-A 3A...H1 Tab Cyclic input and output data with Thyro-A 2A...HRLP1Tab Cyclic input and output data with Thyro-A 3A...HRLP1 Tab Cyclic input and output data with Thyro-A 3A...HRL1Tab b Thyro-A Status Tab a Thyro-A FaultTab Cyclic input and output data with Thyro-A 1A...C02 Tab Cyclic input and output data with Thyro-A 1A...C01Tab Cyclic input and output data with Thyro-A 1A...C03 Tab Supported operating modes Tab Cyclic input and output data with Thyro-A 1A...C05Tab Cyclic input and output data with Thyro-A 1A...C07 Supported operating modes TPM TSC TMUTab Cyclic input and output data TPM automatic mode Input and output data Thyro-Power ManagerTab Cyclic input and output data TPM manual mode Input and output data Thyro Input/Output Unit Tab Cyclic input and output data TSC modeTab Cyclic input and output data TIO mode Input and output data Thyro-Step ControllerTab b Status TPM, TSC, TIO, TMU Tab Cyclic input and output data TMU modeTab b Fault TPM, TSC, TIO, TMU Input and output data Thyro-Measurement UnitRead data record Rdrec Acyclic data transmission parameterizationWrite data record Wrrec External connections Power supplyOperating elements and terminal blocks System interface InterfacesEthernet interfaces Connection diagram Thyro-A Connection diagrams Thyro-AConnection diagram Thyro-S Connection diagrams Thyro-SConnection diagram TSC Connection diagrams TSCSpecific notes Technical DataInstallation ServiceAccessories and options Dimension drawingsApprovals and conformity Detail Controller parameter Appendix aHRL1 Hrlp SST RLP1 U16 R309 Index R309 DAC1OF Page Type value U mains U16 …260 Measuring and cycle time …1500